Before operating this device, please read these instructions completely and save this
manual for future use.

Antes de usar este dispositivo, lea completamente estas instrucciones y guarde este
manual para utilizarlo como referencia en el futuro.

Upper Arm Blood Pressure Monitor

Monitor de Presión Arterial de Brazo

Operating Instructions

Instrucciones de

funcionamiento

Model No. EW3111

Modelo No. EW3111

EW3111取説−英語    02.12.25  9:26    ページ 1

Summary of Contents for EW3111 - ARM BP MONITOR-LOW

Page 1: ...e Panasonic Way 3D 1 Secaucus NJ 07094 Before operating this device please read these instructions completely and save this manual for future use Antes de usar este dispositivo lea completamente estas instrucciones y guarde este manual para utilizarlo como referencia en el futuro Upper Arm Blood Pressure Monitor Monitor de Presión Arterial de Brazo Operating Instructions Instrucciones de funcionam...

Page 2: ...ood vessels Systolic pressure is the pressure exerted when the heart contracts and pumps blood into the arteries Diastolic pressure is the pressure exerted when the heart expands or relaxes When you or your doctor take your blood pressure both your systolic and diastolic pressures are measured If your blood pressure measurement is 120 over 80 120 80 for example your systolic pressure is 120 while ...

Page 3: ...up before having breakfast and before any major activity or exercise If this is not possible however try to take measurements at a specified time prior to breakfast and before you have become active You should relax for about 5 minutes before taking the measurement The following situations may cause substantial variations in blood pressure readings and should therefore be avoided at least 30 minut...

Page 4: ... Blood Pressure Readings Against the World Health Organization WHO Guidelines If your systolic pressure falls in one category but your diastolic pressure in another your level is classified in the higher of the two categories 85 90 100 110 160 180 130 140 Moderate Hypertension SBP 165 DBP 105 Severe Hypertension Blood Pressure Categories SBP 185 DBP 113 e g e g e g e g e g Low Hypertension SBP 156...

Page 5: ...nsistently in excess of 140 mmHg Sys and or 90 mmHg Dia are considered to constitute high blood pressure High blood pressure is a health risk and must be treated without fail Please consult your doctor without delay if the blood pressure indicator repeatedly draws attention to elevated blood pressure values Measurement in progress e g Arm has been moved Cuff not positioned correctly Replace batter...

Page 6: ...ff around the arm 2 to 3 cm 25 32 to 1 3 16 above the elbow Positioning on the Upper Right Arm Inserting replacing batteries 1 Slide off the Battery Cover from the housing 2 Insert four 1 5 V batteries R6 AA ensuring correct polarity 3 Close the Battery Cover Batteries must be replaced when The Replace batteries symbol appears on the display You press the ON OFF Start Button and the display screen...

Page 7: ...rements Release any tension present in your body and refrain from muscle movement such as in the arm or fingers Do not speak while measurement is in progress Measurement in a sitting position 1 Rest your elbows on a table or other level surface 2 Make adjustments so that the height of the cuff and heart are at the same level 3 With the palm of your hand facing up release any tension held in your m...

Page 8: ...ory without pressing the ON OFF Start Button the unit will switch off automatically after approx 30 seconds M R 1 On Off Start M R 1 P min 140 130 90 85 M1 P min 140 130 90 85 M1 Storing blood pressure readings This monitor has enough memory capacity to store 21 readings for two users P min 140 130 90 85 M R 1 M R 2 M1 M2 P min 140 130 90 85 M1 Number of readings in memory M1 and M2 will flash on ...

Page 9: ...rmed Check points Check whether measure ments are being taken correctly and whether the user is assuming the correct posture Make sure the cuff is correctly attached to your upper arm See pages 10 and 11 Check whether the pressure cuff is attached to your upper arm correctly Make sure the tube is fully inserted into its socket See pages 7 and 10 1 Loosely roll up the cuff and place it in the cuff ...

Page 10: ...pressure value is high The systolic pressure value or diastolic pressure value is low The measured values differ significantly The measured value differs from that measured by the doctor The measured value is different for each measurement Possible cause The cuff was held too low i e not at heart level See page 11 The cuff was not attached properly See page 10 You moved your body or you spoke duri...