PAN1322
Application Note
53
Revision 1.2, 2013-12-18
Design Guide
9.3
Preparation for RF Tests in non-signaling mode
To perform RF tests in non-signaling mode, i.e. without a BT tester, the eUniStone has to be configured
through HCI commands, which can only be executed on the eUniStone HCI application. To use the HCI
commands, the HCI application must be downloaded into the EEPROM of the eUniStone module.
Note:
Once the HCI application has been loaded to the module, it cannot be reprogrammed
over the UART anymore. An I2C programmer is needed to restore the module with the
standard SPP application.
The HCI application can be downloaded in 2 ways.
1.
Via UART interface only:
a.
Open eBMU SPP Toolbox and connect to device.
b.
Click “Testing” panel
c.
Click the button ”Read BD-data”
d.
Make a note of the BD_ADDR and Osc_Trim (These will be needed later)
e.
Switch to production mode on, by clicking “Production mode”.
f.
Click “Download Image”.
g.
Select image of HCI application and click “Download” (See
).