3
After turning the power off following the Operating Instructions of the projector,
remove the power plug and check that the surroundings of the lamp unit have cooled
off.
Check that the fan has stopped running.
Have a Phillips screwdriver ready ahead of time.
Remove the screw securing the lamp unit
cover, and then slide the lamp unit cover
a little toward the left, and remove it.
Remove the two screws securing the
fan unit.
Lamp unit cover
Open the fan unit as shown in the
figure.
Remove the screws securing the lamp
units (two for each unit), take hold of
the handles, and remove the lamp units.
Install the new lamp unit.
Use a Phillips screwdriver to securely
tighten the 2 lamp unit fixing screws
(two for each unit).
Lamp unit 2
Handle
Lamp unit 1
Lamp unit
Fixing screws
Secure the two screws for securing the
fan unit tightly.
Slide the cover a little toward the right,
and secure it using the screw for
securing the lamp unit cover tightly.
• Firmly install the lamp unit and lamp
unit cover. If not installed firmly, a
protection circuit will function and the
power will not be turned on.
Attention
• The lamp units are constructed in such a
way that the screws in step
will not fall
through completely.
Note
Lamp unit replacement procedures
CAUTION
The lamp unit will be hot after it
has been used.
You might get burned if you touch it while it is
still hot.
2
Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.
Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled,
explosion might result.
A used lamp unit may burst if it is handled violently.
For disposition of used lamps, request an industrial waste disposal contractor.
If you continue to use a lamp after the replacement time, the lamp may break.
Philips screwdriver is necessary when replacing a lamp unit.
Take care not to slip your hand when using a screwdriver.
Accessories
Air filter : 2 pcs.
Precautions on lamp unit replacement
Timing of lamp unit replacement
The lamp units are consumable parts. The lamp brightness decreases gradually as the cumulative operating time
increases, so periodic replacement is necessary. The replacement guideline is 2 000 hours*
1
, although the lamp
may become dead (will not light) before 2 000 hours*
1
is reached depending on the characteristics of individual
lamps and other factors such as the operating conditions and the installation environment. Therefore, it is
recommended for the user to keep a spare lamp unit.
The risk of the lamp bursting increases after 2 000 hours*
1
of operation, so the lamp unit turns off automatically.
After
1 800 hours*
2
The indication appears for 30
seconds or until any control button
is pressed.
On-screen indication
After
2 000 hours*
1
The indication will not disappear
unless a control button is pressed.
The lamp monitor lights up red
even in standby mode.
REPLACE THE LAMP
Lamp monitor
LAMP
*
1
This is the operating time if the lamp has only been used at the LAMP POWER “HIGH” setting. If the lamp
has only been used at the LAMP POWER “LOW” setting, the operating time is 3 000 hours. When the lamp
has been switched from LAMP POWER “HIGH” to “LOW”, the cumulative operating time from the
conversion formula below will be 2 000 hours.
Lamp operating time = LAMP POWER “HIGH” operating time + (LAMP POWER “LOW” operating time x 2 ÷ 3).
*
2
This is the operating time if the lamp has only been used at the LAMP POWER “HIGH” setting. If the lamp
has only been used at the LAMP POWER “LOW” setting, the operating time is 2 700 hours. When the lamp
has been switched from LAMP POWER “HIGH” to “LOW”, the cumulative operating time from the
conversion formula below will be 1 800 hours.
Lamp operating time = LAMP POWER “HIGH” operating time + (LAMP POWER “LOW” operating time x 2 ÷ 3).
• It is not possible to turn on the power unless two lamp units are installed.
Note
WARNING!
Before replacing the lamp, be sure
to disconnect the power cord plug
from the wall outlet.
WARNING!
Do not disassemble the lamp unit.
CAUTION!
Do not use the old lamp unit.