INSTRUCTION MANUAL

Area ionizer

  

ER-X series 

CME-ERX No.0060-02V

Thank you for purchasing Panasonic products. 

Read this Instruction Manual carefully and thoroughly for the correct and optimum use of 

this product.

Kindly keep this manual in a convenient place for quick reference.

WARNING

 

Never use this product as device for personnel protection.

 

In case of using devices for personnel protection, use products which meet laws or 

standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in 

each region or country.

1

FOR SAFETY USE

WARNING

 

This product produces high voltages.

 

Do not use this product in places where there may be a danger of flammable or 

combustible items being present.

 

To prevent electric shock and to conduct proper discharge, be sure to ground a frame 

ground (F.G.) terminal of a controller.

 

Do not place hands near the discharge needle. Doing so may cause electric shock.

 

Since the tip of the discharge needle is sharp, take sufficient care in handling the 

discharge needle, or injuries may result.

 

The high-voltage cable between the head and the high-voltage unit must be fixed and 

the minimum bend radius is R30 mm or more. 

In case of using at the bend radius R30 mm or less and using at moving part may 

cause fire and break down, etc. of the high-voltage cable.

 

Clean the discharge needle regularly (about once a week). Otherwise, optimum charge 

removal performance may not be achieved, and accidents or operating problems may occur. 

 

If this product is used in a confined space, ozone emitted from this product may be 

detrimental. Be sure to provide ventilation.

 

Do not direct ionized air toward the face. Ozone may cause irritation to places such as 

the nose and throat.

CAUTION

 

This product has been developed / produced for industrial use only.

 

Do not use this product for purposes other than electric charge removal.

 

Do not use this product in environments which are outside the specification range, 

otherwise operating problems or damage may occur. In addition, the operating life of the 

product may become significantly reduced.

 

This product is a precision device. Do not apply a shock to it by dropping, for example. 

Accidents or operating problems may occur.

 

Never disassemble, repair or modify this product. Accidents or operating problems may occur.

 

Do not throw this product in fire. It may explode or toxic fumes may be generated.

 

Do not run the wires together with high-voltage lines or power lines or put them in the 

same raceway.

This can cause malfunction due to induction.

 

When connecting/removing the head or performing wiring or inspection work, be 

sure to turn off the power first. Not doing so may result in accidents, electric shock or 

operating problems.

 

After connecting the cables, check that the connections are correct before turning on the 

power. If the cables are connected incorrectly, operating problems or accidents may occur.

 

Verify that the supply voltage variation is within the rating.

 

In case using switching regulator, be sure to connect F.G. terminal.

 

When using as a CSA and UL compliant product, use a CLASS 2 CSA/UL certified 

power supply, or a CSA/UL certified power supply that has been evaluated as a Limited 

Power Source as specified in CAN/CSA-C22.2NO.60950-1/UL60950-1.

 

Do not use a cable with any damage such as cracks or splitting. Risk of accidents and 

failure.

 

Avoid use in a location with significant steam or dust, or in a location where the product 

may come in direct contact with water, oil, or welding spatter.

 

Avoid use at an elevation higher than 2000m, and outdoor use.

 

Do not touch the discharge needle with hard objects such as tools. If the discharge 

needle becomes broken, it will not provide sufficient charge removal performance, and 

moreover operating problems or accidents may occur.

 

During installation, fasten the product securely. If it is not securely fastened or it is 

subjected to continuous vibration or shock, accidents or operating problems may result.

 

Power cable that are 0.15mm

2

 or more and 30m or less in total length for wiring.

Also, keep the wiring as short as possible in order to prevent noise.

 

When disposing of this product, treat it appropriately as industrial waste. 

 

After  starting  discharge,  it  takes  approximately  30  minutes  for  charge  removal 

performance to stabilize. Therefore, wait 30 minutes before adjusting ion balance.

 

Use the correct combination of head, discharge needle unit and controller.

2

PART DESCRIPTION

Bracket

Discharge needle unit

ER-XANT1

Head 

ER-X001

Head

ER-X□

Discharge needle unit

ER-XANT or ER-XANS

Air inlet

Head

mounting 

bracket

Discharge 

needle

High-voltage cable (Note)

High-voltage unit

Head connection cable

ER-XCCJ2H

ER-XCCJ5H

 or 

ER-XCCJ10H

Controller

ER-XC02

Power cable (optional)

ER-XCC2

 or 

ER-XCC5

High-voltage unit

High-voltage cable (Note)

Air inlet

Note:  The minimum bend radius of the high-voltage cable is R30 mm.

<Controller>

Discharge indicator (green) (Note)
Lights up during discharge , blink-

ing during discharge stopped.

CHECK indicator (orange)
Lights up when dirt, wear, etc. of 

the discharge needle is detected.

Level meter indicator (green)
Indicates static buildup around the 

head or the amount of ion generated 

from the head. 

Discharge control switch
ON: Discharge allowed

OFF: Discharge halt

SET UP button
Stores the settings for the 

amount of ion and the check 

threshold in memory.

Discharge frequency setting switch
Switches between discharge 

frequency settings.

Ion balance setting switch
Sets ion balance.

Various setting switch
Refer to “

6

SETTING.”

ERROR indicator (red)
Lights up when abnormal 

discharge is detected.

Note:  An abbreviation of DISCHARGE. 

3

INSTALLATION

<Head installation>

 

● Using 2 M4 screws or 1 M6 screw, mount the head 

onto the equipment housing. In case using this prod-

uct in where there is vibration, use spring washers 

etc. as a countermeasure. 

 

Loosen the angle adjustment screw, adjust the head 

angle, and then fasten the head with the tightening 

torque of 0.5 N∙m or less. 

 

The position of the head mounting bracket of the 

ER-X001

 

should be at least 20 mm from the end of the head. The 

tightening torque of the screw for head fixation should be 

0.5 N•m or less.

 

After mounting the head, set the controller according 

to the procedures in “

6

 

SETTING

” in order to 

appropriately remove static electricity. 

Angle adjustment

screw

M4 screw

M6 screw

Angle adjustment

screw

Screw for 

head fixation

M4 screw

Notes: 1) Be sure to ground the equipment housing onto which the head is mounted. 

 

2) The distance between the head and the charge removing object should be 30 mm or more.If the static 

buildup of the charge removing object is 30 kV or more, set the distance to 50 mm or more.

 

3) If there is metal near the head or between the head and the charge removing object, ion is absorbed, 

hindering appropriate static removal. Install the head based on the above.  

 

4) In case using the side mounting, the discharge frequency should be 10Hz or more.

The discharge muzzle 

must exceed this line

(surrounding metal.)

Surrounding

metal

 

Back-side mounting

(All frequencies)

50mm or more

 

Side mounting

(10Hz or more)

50mm or more

 

Mouting ER-X001

Surrounding

metal

20mm 

or more

20mm

or more

 

5) When installing two or more heads in face to face or parallel using different frequency, keep the distance be

-

tween the heads 400mm or more.

 When installing the heads face to face, install heads in distance that the heads can parform the charge 

 removal of a side of the object individualy.

 

Face-to-face installation

 

Parallel installation

100mm 

or more

100mm 

or more

50mm or more

50mm 

or more

<High-voltage unit installation>

 

Use 2 M4 screws or 2 M6 screws to fasten the 

head.

The tightening torques for fastening, are as follows.

When using M4 screws: 1.2N·m

When using M6 screws: 2.5N·m

M4 screw

M6 screw

Notes: 1) Do not place any objects on top of the high-voltage unit.

 

2) When using multiple heads, keep the distance of at least  10 mm 

between the high-voltage units.

 

3) When fastening the high-voltage unit using M6 screws, fasten 

before connecting the head connection cable.

 4) 

Please fix the 

high-voltage unit of 

ER-X001

 with M6 screw.

10mm or 

more 

<Controller installation>

 

● Mount the controller on a 35 mm wide DIN rail or using M4 screws. For mounting 

dimensions, refer to “

16

DIMENSIONS

When mounting on a DIN rail

When mounting using M4 screws

1

2

35 mm wide DIN rail

Lock release 

lever

M4 screw

• 

Pull the lock release lever to remove this 

product from the DIN rail. 

• 

The tightening torque should be 1.2 N·m or 

less.

Summary of Contents for ER-X Series

Page 1: ...s product treat it appropriately as industrial waste After starting discharge it takes approximately 30 minutes for charge removal performance to stabilize Therefore wait 30 minutes before adjusting ion balance Use the correct combination of head discharge needle unit and controller 2 PART DESCRIPTION Bracket Discharge needle unit ER XANT1 Head ER X001 Head ER X Discharge needle unit ER XANT or ER...

Page 2: ...harge indicator blinks For accepted frequencies refer to 11 SPECIFICATIONS 3 After mounting the head adjust ion balance using the ion balance setting switch Turn to to shift ion balance to the side Turn to to shift ion balance to the side Ion balance setting switch For head 1 For head 2 Note Generally ion reaching the charge removing object is affected by installation environment nearby metals tem...

Page 3: ...arge removal with air Foreign objects attached to the discharge needle Foreign objects may cause abnormal discharge Clean the discharge needle and its surroundings before use Dew condensation around the discharge needle If the temperature environment changes rapidly abnormal discharge may result due to dew condensation Clean the discharge needle and its surroundings and use it under a stable envir...

Page 4: ... also available Please contact us for details 9 High voltage cables are also available in 1m and 2m lengths Please contact us for details Type Controller Model No ER XC02 Number of charge removal heads connected Maximum 2 units Supply voltage 24V DC 10 Current consumption 450mA or less when connecting 1 heads 800mA or less when connecting 2 heads Indictor Displays status of Head 1 and 2 DSC Discha...

Reviews: