INSTRUCTION MANUAL
Static Remover Fan-type Ionizer
ER-F12 / ER-F12S
Thank you very much for using Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product with a device for personnel protection.
In case of using devices for personnel protection, use products which meet laws
or standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable
in each region or country.
Do not use this product in places where there may be a danger of ��ammable or
combustible items being present.
Clean the discharge needle regularly (about once every two weeks), otherwise
optimum charge removal performance may not be obtained and ��re or operating
problems may occur.
If this product is used in an airtight room, ozone emitted from this product may be
detrimental. Therefore, in order for this product to be used in an airtight room, be
sure to keep the room ventilated.
Do not direct ionized air toward the face. Ozone may cause irritation to places
such as the nose and throat.
Since the tip of the discharge needle is sharp, take ���� cient care in handling the
discharge needle, or injuries may result.
Be sure to ground the frame ground (F.G.) terminal, otherwise electric charge
removal may not be reliable.
1
OUTLINE
This product is a fan-type charge removal device which uses ion generation from
corona discharges.
The device is suitable for a variety of charge removal applications. It is equipped
with a straight louver which is ideal for long-distance charge removal, and an angle
louver which is ideal for wide-range charge removal.
The fan speed can be adjusted to one of four settings.
2
PART DESCRIPTION
Caution label (Note 2)
Power switch
Power connector
LEDs
Bracket
Fan speed
select switch
(Note 1)
M5 screw
M5 screw
Louver
Filter cover
Description of each LED
POWER ...........Lights up when the power is turned on.
(Power indicator)
DSC .................Lights up when discharge is occurring normally.
(Discharge indicator)
DSC ERROR ...Lights up when an abnormal discharge is detected.
(Discharge error indicator)
FAN ERROR ....Lights up when a problem with fan operation is detected.
(Fan error indicator)
Notes: 1) Fan speed select switch
At the time of shipment from the factory, the device is set to fan speed 4 (MAX). Use a
��at-tipped screwdriver to adjust the fan speed.
Notes:
2) Caution label
Attach whichever accessory caution label is written in the appropriate language for the
region of use.
3
I/O CIRCUIT DIAGRAM
4
MOUNTING
Be sure to turn off the power before carrying out angle adjustment for this product,
otherwise accidents or problems with operation may occur.
Remove the bracket from the main unit, and then secure it to the installation
location.
Use the holes in the base of the bracket to secure it with screws.
The vertical angle of the product can be freely changed by loosening the two M5
screws. After adjusting the angle, retighten the screws to secure the device so
that the angle will not change. The tightening torque for the M5 screws at this time
��������������������������
Attach the accessory rubber cushion to bracket as shown in the below diagram to
suit the usage.
5
OPERATION MATRIX
Indicators (
�
: Lights up,
�
: Off)
Error output
(normal
close)
Discharge
operation
Fan
operation
POWER
DSC
DSC
ERROR
FAN
ERROR
Green
Green
Red
Red
Normal
�
�
�
�
ON
ON
ON
Discharge error
�
�
�
�
OFF
OFF
OFF
Fan error
�
�
�
�
OFF
OFF
OFF
Discharge halt input
�
�
�
�
ON
OFF
ON
* Once an error is detected, the error status will be maintained until the power is turned off and back
on again.
Remove the cause of the error and then turn the power back on.
If the cause of the error is not removed, the error status will continue.
* Discharge halt input is disabled when an error status is active.
6
LOUVER SELECTION
Straight louver (blue)
200mm
600mm
700mm
1500mm
Angle louver (white) (Note 1)
200mm
[Diagram with louver attached]
[Diagram of charge removal area]
This product includes two types of louver as accessories. Select the type of louver to
use based on the charge removal area.
Straight louver
This louver provides excellent direction stability for the air. It is ideal for cases where
rapid charge removal for objects is required, or when the object is some distance away.
Angle louver
This louver is excellent at dispersing the air. It is ideal for charge removal over a wide
area.
Notes: 1) The discharge needle unit is loaded on the straight louver before shipment. To replace it
with the angle louver, refer to the discharge needle unit installation procedure in "
7
CARE
AND MAINTENANCE
" in this manual.
Notes:
2) If no louver is attached, the device will not turn on even when the power is supplied.
7
CARE AND MAINTENANCE
Be sure to turn off the power before carrying out cleaning and maintenance.
The discharge needle has a sharp point, so be very careful when cleaning the needle.
If the device is used for a long period, dust and other foreign particles may
accumulate on the discharge needles or on the fan ��lter, and so the needles and
��lter should be cleaned before use.
If the device is not cleaned regularly, the charge removal performance will drop and
operating problems or accidents may occur. Clean the device regularly, using the
following as a guide.
Discharge needle unit: Every 2 weeks
Fan intake ��lter: Every 2 weeks
The discharge needle is a consumable part. If the discharging performance is not
restored after the discharge needles have been cleaned, it is recommended that
you replace the discharge needle unit. It is recommended that you replace the
discharge needle unit after about 10,000 hours of operation.
Cleaning the discharge needle unit
Check that the power is turned off and that the fan has completely stopped.
Following the removal procedure of the louver, remove the louver from the main
unit.
Clean with the discharge needle loaded. Use a cotton swab or similar tools
moistened with alcohol to clean the discharge needles and the areas around them.
If the needles are particularly dirty, use a brush (such as a toothbrush) moistened
with alcohol to rub them clean, and then use a cotton swab to wipe them.
<When using a commercially-available ultrasonic cleaner for cleaning>
Following the removal procedure of the discharge needle unit, remove the
discharge needle unit from the louver, and immerse the discharge needle unit
into the cleaning tank to clean them. After that, dry the discharge needle unit well.
Following the installation procedure, install the discharge needle unit to the louver.
Following the installation procedure, install the louver to the main unit.
[Louver removal/installation procedure]
Louver removal procedure
Louver installation procedure
When installing the louver to the main unit, align and insert the tongue of the
louver into the groove of the main unit. After inserting the tongue into the groove,
turn the louver clockwise to install.
* Do not touch inside the device when removing and installing the louver, otherwise accidents
or problems with operation may occur.
[Discharge needle unit removal/installation procedure]
When using a ultrasonic cleaner for cleaning,
remove the discharge needle unit.
Discharge needle unit removal procedure
Discharge needle unit installation procedure
As shown in the �gure above, install the louver and the discharge needle unit so that
the claw of the louver is inserted into the hole of the discharge needle unit. (Note: 3)
Turn the discharge needle unit clockwise until it stops to install.
Notes: 1) If replacing the louver, install the discharge needle unit to the replacement louver.
Notes:
2) When turning the discharge needle unit, do not apply any more force than is necessary,
otherwise the louver or the discharge needle unit may become damaged.
Notes:
3) ����rm the side of the discharge needle unit to install. If installed on the wrong side, the
discharge needle unit or the louver may become damaged.
Option (sold separately)
ER-F12ANT
: Discharge needle unit x 1
Cleaning and replacement procedure for fan �lter
Install a ��lter in accordance with the operating environment.
Remove the ��lter cover. Disengage the clasps in the places indicated by in the illustration
below, and then pull the ��lter cover in the direction of the arrow to remove it. (Refer to the
illustration below.)
Clean away any dust and dirt adhering to the ��lter. If the ��lter is particularly dirty,
wash it in water. If washing the ��lter in water, let it dry thoroughly before reusing it.
Install the ��lter. Install the ��lter cover.
* If the device is used while the ��lter is still wet, accidents or problems with operation may occur.
* If the ��lter will not come clean, it should be replaced.
* Be careful not to let anything get inside the device while the ��lter is removed.
Option (sold separately)
ER-F12FX5
: Replacement ��lter x 5
Filter cover
Filter cover
Filter
Main unit
Main unit
8
TROUBLESHOOTING
Be sure to turn off the power before checking the discharge unit or the fan unit.
Problem
Main cause
Remedy
Discharge error
indicator (DSC
ERROR)
lights up.
Condensation
Foreign objects
F.G. not connected
�� An abnormal discharge is probably occurring.
Turn off the power and check that the tip of the
discharge needle is intact and free from foreign objects,
and also check that the discharge needle unit is
correctly installed to the louver.
�� If the error indicator remains lit even after the discharge
needle has been cleaned, check if the area around the
needle is dirty.
������������������.G. terminal is securely grounded.
Fan error indicator
(FAN ERROR)
lights up.
Fan is covered
Fan is blocked
Foreign objects
�� Turn off the power and check that the �lter is not dirty or
blocked.
�� Check that there are no foreign objects inside the
product.
9
SPECIFICATIONS
Type
Standard
fan type
Low-volume fan type
Item
Model No.
ER-F12
ER-F12S
Charge removal time
1 sec. approx. (Note 1)
1.5 sec. approx. (Note 1)
Ion balance
±10 V or less (Note 2)
±10 V or less (Note 2)
Power supply voltage
24 V DC ±10%
24 V DC ±10%
Power consumption
700 mA or less
400 mA or less
Discharge method
High-frequency AC method
High-frequency AC method
Discharge output voltage
±2 kV approx.
±2 kV approx.
Max. fan speed
5.3 m/s (Note 2)
4.0 m/s (Note 2)
Max. fan volume
3.68 m
3
/min
2.50 m
3
/min
Error output
NPN transistor/open collector
��������������������������
��Applied voltage: 30 V DC or less (between output terminal and 0 V)
�����������������������������������������������������������
Output operation
OFF when discharge error or fan error detected
Normally ON
Short-circuit protection
Incorporated
Discharge halt output
Discharge halt: Short-circuited to 0 V
Discharge (operation start): Open
Indicators
POWER
Green LED (Lights up when power on)
DSC
Green LED (Lights up during normal discharge)
DSC ERROR
Red LED (Lights up when discharge error detected)
FAN ERROR
Red LED (Lights up when fan error detected)
Ozone generation amount
0.04 ppm or less (Note 1)
Ambient temperature
0 to + 50°C (No dew condensation) / Storage : -10 to + 65°C
Ambient humidity
35 to 65% RH (No dew condensation) / Storage : 35 to 65% RH
Vibration resistance
10 to 55 Hz frequency, 0.75 mm amplitude in X, Y and Z directions for two hours each
Material
Enclosure: ABS Louver: ABS Discharge needle: Tungsten
Discharge needle unit: PBT Bracket: SPHC
Grounding method
C (capacitor) grounding
Weight
790g approx. (main unit only)
Accessories
●
Louvers
●
Caution label: 1 set
Straight louver: 1 (Note 3 )
●
Rubber cushion: 1
Angle louver: 1
Notes: 1) Typical value at 200 mm from directly in front of discharge outlet, fan speed MAX, straight
louver, with no ��lter installed.
Notes:
2) Typical value at 300 mm from directly in front of discharge outlet, fan speed MAX, straight
louver, with no ��lter installed.
Notes:
3) The discharge needle unit is loaded on the straight louver before shipment.
10
CAUTIONS
This product has been developed / produced for industrial use only.
Do not use this product for any purpose other than charge removal and dust removal.
Do not use this product in enviroments which are outside the ������cation range,
otherwise operating problems or damage may occur. In addition, the operating life
��������������������������������cantly reduced.
Never disassemble, repair or modify this product, otherwise operating problems or
accidents may occur.
Do not dispose of this product by burning it, otherwise it may explode or toxic
fumes may be generated.
This product generates ozone, so be sure to provide adequate ventilation if using it
���������ned space.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
Be sure to turn off the air and the power supply before carrying out any cable
connection or inspection work. If this is not done, operating problems, damage or
electric shocks may occur.
After connecting the cables, check that the connections are correct before turning on the
power. If the cables are connected incorrectly, operating problems or accidents may occur.
Verify that the supply voltage variation is within the rating.
It takes approximately 5 seconds after the power is turned on before the fan
operation stabilizes. To ensure proper charge removal performance, do not use the
������������������cient time has elapsed.
Do not turn the power back on immediately after it has been turned off, otherwise
operating problems or accidents may occur. In addition, the operating life of the
product may become ������cantly reduced. Wait at least 2 seconds before turning
the power back on again.
Do not use any cables which have any damage (such as splitting or cracking),
otherwise operating problems or accidents may occur.
Avoid using the product in places where there are high levels of steam or dust in
the air or where it might be directly exposed to water, oil or welding spatter.
Do not touch the discharge needle with hard objects such as tools. If the discharge
needle becomes broken, it will not provide ����cient charge removal performance,
and moreover operating problems or accidents may occur.
Do not use this product while the ��lter is blocked, otherwise accidents or problems
with operation may occur.
Clean or replace the ��lter at regular intervals.
Be sure to turn off the power before replacing the ��lter.
Install the product so that it is at least 100 mm away from the objects being charged.
When installing this product, be sure to securely install the main unit and the
bracket. If they are not securely installed or if constant vibration or shocks are
applied, accidents or problems with operation may occur.
Do not place any objects which may obstruct air ��ow within 20 mm the front of the
fan air intake, otherwise accidents or problems with operation may occur.
Use cables that are 0.15 mm
2
or more and 30 m or less in length for wiring.
Also, keep the wiring as short as possible in order to prevent naise.
If this product ceases functioning or is no longer required, dispose of it according to
appropriate local waste disposal regulations.
③
①
④
⑤
②
D
1
: Power supply reverse connection protection diode
D
2
: Output protection diode
D
3
: Input protection diode
Z
D
: Surge voltage absorption Zener diode
T
r
: NPN output transistor
Internal circuit
Users’ circuit
*1
Non-voltage contact or
NPN transistor/open collector
or
Low (0V)
: Discharge halt
High (Open) : Discharge (operation start)
Main circuit
24V DC
±10%
30V
DC max
50mA max
Error output
Discharge halt input
Load
l
Pin layout
Terminal no. Terminal name
(From cable insertion side)
F.G.
+V
0V
Error output
Discharge halt input
Recommended wire : AWG 25~12
●
Option (sold separately)
ER-FAPS-J
:
AC adapter
●
About wiring cable <Recommendation>
Compatible electric wire:
AWG25#25 - 12
(Nominal cross-sectional area: 0.16 - 3.3 m
2
)
Work dimension of electric wire: 7 mm
(figure below)
* Do not solder-plate the end of the electric wire
to be wired to the connector. The tightened
screw may become loose and the wiring may be
disconnected.
Open
Turn the louver in the direction
of the arrow.
Remove the louver from the main unit.
Groove of the
main unit
Tongue of the
louver
Hold the louver and turn the discharge needle
unit counterclockwise. (Note: 2)
Remove the discharge needle unit from the
louver to the direction shown in the figure.
Discharge
needle unit
Louver (Note: 1)
Hole of the discharge
needle unit
Details of the
central part
Claw of the louver
MJE-ERF12F12S No.0031-23V
http://panasonic.net/id/pidsx/global
PRINTED IN CHINA
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
© Panasonic Industrial Devices SUNX Co., Ltd. 2012
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com