background image

Thank you very much for purchasing Panasonic products. 
Read this Instruction Manual carefully and thoroughly for 
the correct and optimum use of this product. Kindly keep 
this manual in a convenient place for quick reference.

ە

ە

Never use this product as a sensing 
device for personnel protection.
In case of using sensing devices for personnel 
protection, use products which meet laws and standards, 
such as OSHA, ANSI or IEC etc., for personnel protection 
applicable in each region or country.

WARNING

Note: Each condition for use that the standards require is under 

less than 2,000m above sea level.

ە

ە

ە

ە

ە

ە
ە

ە

ە

ە

ە
ە

Do not run the wires together with high-voltage lines or 
power lines or put them in the same raceway. This can 
cause malfunction due to induction.
In case noise generating equipment (switching 
regulator, inverter motor, etc.) is used in the vicinity of 
this product, connect the frame ground (F.G.) terminal 
of the equipment to an actual ground.
Take care that the sensor is not directly exposed to fluorescent 
light from a rapid-starter lamp, a high frequency lighting device 
or sunlight etc. as it may affect the sensing performance.
If an external surge voltage exceeding 4kV (DC-voltage: 
1kV) is impressed, the internal circuit will be damaged, 
and a surge suppressing element should be used.
Do not use during the initial transient time (50ms) after 
the power supply is switched on.
This sensor is suitable for indoor use only.
A mechanical structure is employed for the distance 
adjuster of this product. Take care not to drop the product.
Do not use this sensor in places having excessive 
vapor, dust, etc., or where it may come in direct 
contact with water, or corrosive gas.
Take care that the sensor does not come in contact 
with water, oil, grease, organic solvents, such as, 
thinner, etc., strong acid or alkaline.
This sensor cannot be used in an environment 
containing inflammable or explosive gases.
Never disassemble or modify the sensor.
Due to the configuration of the circuit, a slight noise 
may be generated in this product, however, this is not 
a problem.

WIRING CONNECTIONS

5

ە

ە

Check all wiring before applying power since incorrect 
wiring may damage the internal circuit.
Also, carefully tighten the terminal screws so that the 
wires of adjacent terminals do not touch.
The mounting hole for screw the terminal cover fixing
inclines 70 degrees to the 
terminal cover, as shown 
in the figure below.
To avoid damaging this 
product or a screw, take 
care when tightening or 
loosening a screw.

70

r

Screw for terminal
cover fixing

Screwdriver

ە

To maintain a watertight performance, the cable should 
have an outer diameter between 

ȭ

9 to 

ȭ

11mm with a 

smooth covering material that allows the accessory 
conduit connector to be securely tightened, however, the 
tightening torque of the screw should be of 1.5 to 2.0N

m.

Composition of a conduit connector, and process-
ing of a cable

Gland

Gland packing (Note)

Conduit connector

Note: When assembling the conduit connector, take care of the 

direction of the gland packing.
Furthermore, in order to maintain a watertight performance, fit the 
gland packing such that the seating surface of the gland packing 
contacts the packing holder part of the terminal cover evenly.

Power supply

Output

37mm

25mm

EQ-500 Series

Adjustable Range Reflective

Photoelectric Sensor

INSTRUCTION
MANUAL

MJE-EQ500 No.0040-93V

Sensing mode

Switch either BGS or FGS function

2ms or less (Depends on the timer setting period for 

EQ-51

ڧ

T

)

Adjusting screwdriver: 1 pc.

Accessory

100g approx.

85g approx.

Weight

Extension up to total 100m is possible with 0.3mm

2

, or more, cabtyre cable

Cable length

Suitable for round cable 

ȭ

9 to

ȭ

11mm

Cable

Screw-on terminal connection

Connection method

Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate

Material

2-segment photodiode

Receiving element

Infrared LED (modulated)

Emitting element

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

-25 to +55

Υ

 (No dew condensation or icing allowed), Storage: -30 to +70

Υ

Ambient temperature

IP67 (IEC)

Protection

Incorporated (Note 3)

Automatic interference 
prevention function

EQ-5

ڧ

T

: Selectable from ON-delay and OFF-delay (0.1 to 5 sec. variable)

Timer function

20ms or less (Depends on the timer setting period for 

EQ-50

ڧ

T

)

Response time

Short-circuit protection

Incorporated

Output operation

Switchable either Detection-ON or Detection-OFF

Output

Relay contact 1a

Switching capacity: 250V AC 3A (resistive load)

30V DC 3A (resistive load)

Electrical life: 100,000 or more operations

(switching frequency 1,200 times/hour)

Mechanical life: 50,000,000 or more operations

(switching frequency 18,000 times/hour)

NPN open-collector transistor

Maximum sink current: 100mA

Applied voltage: 30V DC or less (between output and 0V)

Residual voltage: 1V or less (at 100mA sink current)

0.4V or less (at 16mA sink current)

PNP open-collector transistor

Maximum source current: 100mA

Applied voltage: 30V DC or less (between output and +V)

Residual voltage: 1V or less (at 100mA source current)

0.4V or less (at 16mA source current)

Power / Current 
consumption

AC: 4VA or less (With timer: 5VA or less)
DC: 3W or less (With timer: 4W or less)

45mA or less

12 to 24V DC

s

10%

Ripple P-P 10% or less

Supply voltage

24 to 240V AC 

s

 10% or 12 to 240V DC 

s

 10%

Ripple P-P 10% or less

Hysteresis (Note 2)

10% or less of operation distance

0.1 to 2.5m

0.1 to 1.0m

0.1 to 2.5m

0.1 to 1.0m

Sensing range (Setting 
distance maximum) (Note 2)

Adjustable range (Note 1) (Note 2)

0.2 to 2.5m

0.2 to 1.0m

0.2 to 2.5m

0.2 to 1.0m

EQ-511T

EQ-511

EQ-512T

EQ-512

Short sensing range

DC-voltage

EQ-501T

EQ-501

EQ-502T

EQ-502

Short sensing range

Multi-voltage

Item

With timer

Model No.

Type

Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state where this 
product is mounted, be sure to check the operation with the actual sensing object to be used.

Notes: 1) 

2) 
3) 

The adjustable range stands for the maximum sensing range which can be set with the adjuster.
The adjustable range, the sensing range and the hysteresis are specified for white non-glossy paper (200

™

200mm) as the object.

When the sensors are mounted closely, use them in the interference prevented area, as shown below.

L mm
or more

1

2

3

0

60

20

80

40

Mounting interval L (mm)

Setting range (m)

Interference 
prevented area

L mm
or more

L mm
or more

L mm
or more

Mounting interval L (mm)

Setting range (m)

0

150 200

50

250

100

1

2

3

Interference 
prevented area

SPECIFICATIONS

1

FUSE 5A FAST BLOW

Short-circuit protective device

100A

Rated conditional protective device

12%

Excess gain

20ms

Turn off time

25Hz

Frequency of operation cycle

3

Pollution degree

2.5kV

Impulse withstanding voltage

AC-12/DC-12

Utilaization category

Description

IEC 60947-5-2: 1998

Refering standard

Item

INFORMATION RELATING TO 
LOW VOLTAGE DIRECTIVE
(Multi-voltage type only)

2

ە

ە

ە
ە
ە

This product has been developed / produced for 
industrial use only.
Make sure that the power supply is off while wiring 
and adjusting.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching 
regulator, ensure that the frame ground (F.G.) 
terminal of the power supply is connected to an 
actual ground.

CAUTIONS

3

ە

The tightening torque should be 0.8N

m or less.

Sensor 
mounting 
bracket

MS-EQ5-01

(Optional)

M5 

QXW

M5 (length 32mm)
screw with washers

ە

Care must be taken regarding the sensor mounting 
direction with respect to the object's direction of movement.

ە

ە

ە

If a specular body is present in the background, wrong 
operation may be caused due to a small change in the 
angle of the background body. In that case, install the 
sensor at an inclination and confirm the operation with 
the actual sensing object.
This product is not easily affected by the reflected light 
intensity since this sensor is the adjustable range reflective 
type. When the reflected light intensity is remarkably low, the 
sensing range may be affected. In that case, mount the 
sensor, while checking light-up of the stable indicator (green). 
Mounting screws of the terminal cover and display 
cover should certainly be tightened to maintain the 
water tight rating, however, the tightening torque of the 
screws should be of 0.3 to 0.5N

m.

ە

ە

When detecting a specular object (aluminum or copper 
foil, etc.) or an object having a glossy surface or 
coating, please take care that there are cases when 
the object may not be detected due to a small change 
in angle, wrinkles on the object surface, etc.
When a specular body is present below the sensor, use the 
sensor by tiling it slightly upwards to avoid wrong operation.

Sensing object

Good

Sensing object

Good

Do not make the 
sensor detect an 
object in this direction 
because it may cause 
unstable operation.

Sensing object

Not good

Specular
face

Specular
face

Tilt

Good

Not good

MOUNTING

4

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG