1.1.2 LEAKAGE CURRENT HOT CHECK (See
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15
μ
F capacitors, between each exposed
metallic part on the set and a good earth ground such as a water pipe, as shown in
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across
the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson
Model 229 or equivalent) may be used to make the hot checks, leakage current mu3st not exceed
1/2 milliamp. In case a measurement is outsideofthe limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and rechecked before it is returned to the
customer.
file:///C|/Documents and Settings/eDOK/
Рабочий
стол
/DVD-S35xx/s0101020000.html03.10.2007 22:43:44
Summary of Contents for DVD-S35GD
Page 20: ......
Page 129: ...DVD S35GCS GCU GC GCA GD PL PX POWER SUPPLY SCHEMATIC DIAGRAM ...
Page 131: ...DVD S35EE GN POWER SUPPLY SCHEMATIC DIAGRAM ...
Page 133: ...DVD S35PLA POWER SUPPLY SCHEMATIC DIAGRAM ...
Page 147: ...DVD S35GCS GCU GC GCA GD EE GN PL PLA PX MOTOR SCHEMATIC DIAGRAM ...
Page 149: ...DVD S35GCS GCU GC GCA GD EE GN PL PLA PX OPERATION SCHEMATIC DIAGRAM ...
Page 168: ...DVD S35GCS GCU GC GCA GD EE GN PL PLA PX MOTOR P C B REP3501A C 1 A B C D 2 3 4 5 MOTOR P C B ...
Page 213: ...16 3 POWER SUPPLY SCHEMATIC DIAGRAM DVD S35PLA DVD S35PLA POWER SUPPLY SCHEMATIC DIAGRAM 49 ...
Page 214: ...16 3 POWER SUPPLY SCHEMATIC DIAGRAM DVD S35PLA DVD S35PLA POWER SUPPLY SCHEMATIC DIAGRAM 49 ...