40
9 Measurements and Adjustments
9.1.
Introduction
When servicing this unit, make sure to perform the adjustments necessary based on the part(s) replaced.
Before disassembling the unit, it is recommended to back up the camera data stored in flash-rom as a data file.
IMPORTANT NOTICE (After replacing the MAIN P.C.B.)
After replacing the MAIN P.C.B., it is necessary to use the “DIAS” software to allow the release of adjustment flag(s).
The Adjustment software “DIAS” is available at “TSN Website”. To download, click on “Support Information from NWBG/VDBG-
AVC”.
*DIAS (DSC Integrated Assist Software)
NOTE: (When replacing the Lens unit, Master flange unit and CCD unit)
• When the CCD unit is unavoidably removed for Lens unit, Master flange unit and CCD unit replaced, an optical tilt adjustment is
necessary after parts are exchanged.
• The adjustment software (DSC_Tilt) is necessary to execute an optical tilt adjustment.
• The adjustment software “DSC_Tilt” is available at “TSN Website”, therefore, access to “TSN Website” at “Support Information
from NWBG/VDBG-AVC”.
9.2.
Before Disassembling the unit
9.2.1.
Initial Setting Release
The cameras specification are initially set in accordance with model suffix (such as EB, EG, GK, GC, and so on.).
Unless the initial setting is not released, an automatic alignment software in the camera is not able to be executed when the align-
ment is carried out.
Note:
The initial setting should be again done after completing the alignment. Otherwise, the camera may not work properly.
Therefore as a warning, the camera display a warning symbol “ ! ” on the LCD monitor every time the camera is turned off.
Refer to the procedure described in “3.4.2 INITIAL SETTINGS” for details.
[ How to Release the camera initial setting ]
Preparation:
• Attach the Battery or AC Adaptor with a DC coupler to the unit.
(Since this unit has built-in memory, it can be performed without inserting SD memory card.)
1. Turn the Power on.
2. Press the [ MODE ] button, and then touch the [ NORMAL PICTURE ] on the touch panel.
3. Turn the Power off.
(Rotate the Mode dial to adjust to the [ NORMAL PICTURE ] mode. (Camera mark))
Step 1. Temporary cancellation of “INITIAL SETTINGS”:
Set the [ REC ]/[ PLAYBACK ] selector switch to “[ REC ] (Camera mark)”.
While keep pressing “[ WIDE ] of Zoom lever” and [ MODE ] button simultaneously, turn the Power on.
Step 2. Cancellation of “INITIAL SETTINGS”:
Set the [ REC ]/[ PLAYBACK ] selector switch to “[ PLAYBACK ]”.
Press “[ WIDE ] of Zoom lever” and [ MODE ] button simultaneously. (The camera will beep after this.)
Turn the Power off. (The warning symbol “ ! ” is displayed on the LCD monitor.)
Summary of Contents for DMC-FX70EB
Page 13: ...13 4 Specifications ...
Page 24: ...24 Fig D2 8 3 2 Removal of the Sub Operation FPC Unit PCB Frame Fig D3 ...
Page 25: ...25 8 3 3 Removal of the LCD Unit Fig D4 8 3 4 Removal of the Top Operation Unit Fig D5 ...
Page 26: ...26 8 3 5 Removal of the Flash Top P C B and Speaker Fig D6 Fig D7 ...
Page 28: ...28 8 3 9 Removal of the Battery Case Fig D11 Fig D12 8 3 10 Removal of the Jack Door Fig D13 ...
Page 38: ...38 8 7 Removal of the Focus Motor ...
Page 45: ...45 ...