Programming
T1 Settings Added for Networking
DBS-2.3/9.2-540
T1 Networking - Revised April 2000
Page 93
Parameter
Wink Signal Output Timer
Description
Sets the duration for a Wink signal.
Address
FF1 8# 4# 8# 3# (NWG)# 14# (0-8)#
Options
0=140 ms
1=160 ms
2=180 ms
3=200 ms
4=220 ms
5=240 ms
6=260 ms
7=280 ms
8=300 ms
Parameter
Wink Signal Detect Timer
Description
Sets the minimum time for determining a wink.
Address
FF1 8# 4# 8# 3# (NWG)# 15# (0-10)#
Options
0=40 ms
1=60 ms
2= 80 ms
3=100 ms
4=120 ms
5=140 ms
6=160 ms
7=180 ms
8=200 ms
9=220 ms
10=240 ms
Parameter
Wink Glare Timer (Outpulse Delay)
Description
Sets the time to wait after a wink before signalling on a
trunk.
Address
FF1 8# 4# 8# 3# (NWG)# 16# (0-15)#
Options
0=no wait
1=20 ms
2= 40 ms
3=60 ms
4=80 ms
5=100 ms
6=120 ms
7=140 ms
8=160 ms
9=180 ms
10=200 ms
11=250 ms
12=300 ms
13=350 ms
14=400 ms
15=450 ms