background image

ENGLISH 

2-26

Read through the Installation Instructions before you proceed with the installation.

In particular, you will need to read under the “Safety Precautions” on page 2.

FRANÇAIS  

27-33

Lisez les instructions d’installation avant de commencer l’installation.

En particulier, vous devez lire la section « Consignes de sécurité » en page 4.

ESPAÑOL  

34-40

Lea las Instrucciones de instalacion antes de proceder con la instalacion del equipo.

En concreto, deberá leer detenidamente la sección “Precauciones de seguridad” situada en la página 5.

DEUTSCH  

41-47

Lesen Sie die Installationsanleitung aufmerksam durch, bevor Sie mit der Installation beginnen.

Lesen Sie insbesondere die Sicherheitshinweise auf S. 7 sorgfältig durch.

ITALIANO  

48-54

Leggere le Istruzioni di installazione prima di procedere con l’installazione.

Prestare particolare attenzione alla sezione “Precauzioni di Sicurezza” a pagina 8.

NEDERLANDS 

55-61

Lees de installatie-instructies voordat u verder gaat met de installatie.

U moet in het bijzonder de “Veiligheidsvoorschriften” op pagina 10 lezen.

PORTUGUÊS  

62-68

Leia cuidadosamente as instruções de instalação antes de prosseguir com a instalação.

Em particular, é necessário ler as informações na secção “Precauções de segurança” na página 11.

TÜRKÇE 

69-75

Kuruluma başlamadan önce Kurulum Talimatlarını baştan sona okuyun.

Özellikle 12. sayfadaki “Güvenlik Önlemleri” kısmını okumanız gerekecektir.

POLSKI 

76-82

Przed przystąpieniem do instalacji należy przeczytać instrukcje instalacyjne, 

 

a w szczególności „Środki ostrożności” na stronie 14.

РУССКИЙ

 

83-89

Прежде чем приступать к установке, прочитайте инструкцию по установке.

В частности, следует прочитать раздел «Техника безопасности» на стр. 15.

УКРАЇНСЬКА

 

90-96

Перед початком установки уважно прочитайте iнструкцію з установки.

Особливу увагу зверніть на розділ «Запобіжнізаходи» на ст. 17.

ҚАЗАҚСТАН

97-103

Орнатуды жалғастырмай тұрып Орнату нұсқауларын оқып шығыңыз.

Әсіресе, 18-беттегі «Қауіпсіздік шаралары» бөлімін оқу керек.

Installation Instructions

RAC Interface Adaptor

Model No. 

CZ-CAPRA1

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

85464369884010

H0316-0

CV6233324456

Panasonic Corporation

http://www.panasonic.com

P

OLSKI

E

NGLISH

F

RANÇAIS

E

SPAÑOL

D

EUTSCH

I

TALIANO

N

EDERLANDS

P

ORTUGUÊS

T

ÜRKÇE

Р

УССКИЙ

У

КРАЇНСЬКА

Қ

АЗАҚСТАН

Summary of Contents for CZ-CAPRA1

Page 1: ...a 10 lezen PORTUGUÊS 62 68 Leia cuidadosamente as instruções de instalação antes de prosseguir com a instalação Em particular é necessário ler as informações na secção Precauções de segurança na página 11 TÜRKÇE 69 75 Kuruluma başlamadan önce Kurulum Talimatlarını baştan sona okuyun Özellikle 12 sayfadaki Güvenlik Önlemleri kısmını okumanız gerekecektir POLSKI 76 82 Przed przystąpieniem do instala...

Page 2: ...rred due to the unauthorised installation methods are not covered by the product warranty z z This controller shall be installed in accordance with National Wiring Regulations z z Read the installation instructions of devices to be connected as well z z When relocating or repairing this controller provide the Installation Instructions to the servicing personnel WARNING z z Turn off the circuit bre...

Page 3: ...5 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a parti...

Page 4: ...ng operations from the central control device can be performed z z Operations to start stop the room air conditioner switch the operation mode and set the temperature fan speed and fan direction up down z z Monitoring the operation status and abnormality of room air conditioner z z Prohibiting the remote control operation of room air conditioner z z Using ON OFF contact of external connection can ...

Page 5: ...21 z zBasic Wiring Diagram 22 z zMounting and Wiring 23 z zConnecting External Equipment 25 z zSetup 26 CONTENTS Dimensions RAC connection wiring 1 5P White 4P Red Length 1 9 m Screw 4 M3 8 x 16 Installation Instructions 1 Clamper 3 70 120 32 5 mm 108 35 Installation Precautions Installation Location z z Avoid the following locations for installation Location where the controller will be splashed ...

Page 6: ...Normal Blinking Abnormal OFF No power is supplied from the room air conditioner 2 2 1 While pushing the push button by using a round bar or finger insert the external I O wiring securely from the wiring insertion slot 2 Pull the external I O wiring lightly and confirm it does not come off Be sure to set the termination plug 1 If using one outdoor unit set the termination resistor to SHORT at one l...

Page 7: ...e wiring coat 2 Cover with the tape 3 Attach ring pressure terminal Shield mesh Strip Shield mesh Insulation tape Attention Ground the shield on both sides of shield wiring otherwise an operation error from noise may occur Shield wiring Ground Ground Mounting and Wiring Method 1 Connect the RAC connection wiring supplied to the room air conditioner For attachment removal of the front panel grille ...

Page 8: ...connecting external equipment Connect the external I O wiring P 25 Cut here with a nipper and remove the burr with a file As shown in step 4 or 5 pass the clamper supplied through the hole and fix the wiring z z When the settings are complete P 26 attach the top case Case fixing screws Top case Bottom case Clamper supplied Pass through the hole Clamper supplied Functional ground FG Pass through th...

Page 9: ...short as possible Connection Specifications Attention 4 6 7 8 5 Status output Voltage contact a Static Relay output Contact allowable voltage Max DC12 V Contact allowable current Max 100 mA Minimum application load DC5 V 1 mA Common COM DC power DC 12 V DC power DC 12 V Alarm output OUT 1 Operation Output OUT 2 DC power 12 V Coil Relay Relay Controller side External equipment side Condition Circui...

Page 10: ...uit Remote control operation is prohibited Open circuit Remote control operation is permitted OFF ON Input 1 Start stop signal Pulse Open circuit Short circuit 300 ms or more With Open the start stop status is reversed Start Stop Input 2 Signal Static prohibiting remote control Short circuit Remote control opera tion is prohibited Open circuit Remote control operation is permitted Be sure to turn ...