Please observe these following safety precautions when using your air conditioner.

Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.

Improper grounding could cause electric shock.

Gas leaks near the unit could cause fire.

Ensure that the drainage piping is connected properly.

Otherwise, water will leak out.

This sign warns of risk of death or serious injury.

1

SAFETY PRECAUTIONS

INSTALLATION PRECAUTIONS

OPERATION PRECAUTIONS

• Do not modify the length of the power cord or use an extension cord.
• Do not touch or operate with wet hands. Do not modify or damage the cord.
• Do not turn on the unit by inserting the power plug. Do not switch off the unit by pulling out the

power plug.

• Avoid an extended period of direct airflow.
• Do not insert your fingers or other objects into the unit, rotating parts may cause injury.
• Do not try to repair the unit yourself.

• Plug in properly before operating and use a specified power cord.
• If abnormal conditions (burnt smell, etc.) occur, switch off and remove the power plug.

Main control panel

2

PART IDENTIFICATION

MAIN UNIT

Air inlet louvre

Air filter

(behind the front intake grille)

Cabinet

Front intake grille

Front grille

Power cord

Vertical airflow direction vane

(Airflow direction adjustment up-down).

The vertical airflow direction vane is

controlled by positioning the vane to

discharge the air upwards, downwards

or straight out.

Air Swing Switch

OFF

Stops the operation of Air Swing.

ON

Air Swing is in operation. (Only

for LOW COOL and HIGH COOL

operation.)

OPERATION CONDITIONS

Use the air conditioner under the following conditions:

• Operating temperature range.

NOTE:

 Humidity may exceed 90%

Indoor side

Outdoor side

D.B.T.

W.B.T.

D.B.T.

W.B.T.

Max. Temperature

32

23

43

26

Min. Temperature

21

15

21

15

(unit in °C)

D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature

Continuous operation at over 90% high humidity may create condensation and result in waterdrops on the

intake and outlet vanes.

4

AIR CONDITIONER INSTALLATION

• When installing, use the nearest power outlet. Make sure the power outlet is easy to

reach so you can quickly disconnect your air conditioner in case of emergency.

• Ensure that the air conditioner is well supported, securely fastened, easily reachable

and not obstructed.

• Avoid locations with: salty or sulphurous air, draughts, dampness and flammable gas.

• If you install the drainage system, be sure to channel the condensed water to a suitable

location.

• Covers, obstructions and unsteady support may cause excessive operating noise and vibration.
• The rear end of the air conditioner is splash proof. You need not shield or cover it.

Dimension

• There should not be any obstacles surrounding the

unit.

• Prepare an installation hole slightly bigger than the

cabinet size.

• Left  and  right  sides  of  the  unit  should  be  at  least

15cm away from the wall.

CHOOSING THE INSTALLATION LOCATION

PREPARATIONS BEFORE INSTALLATION

For

decreased

cooling

For

increased

cooling

Low fan speed operation

(without cooling)

High fan speed operation

(without cooling)

Low fan speed with

cooling operation

Main Control Knob

Thermostat Control Knob

This sign warns of injury or damage to property.

• Do not use the unit for other purposes, than its intended use.

• Do not remove the power plug by pulling the cord.

• Do not block the air intake and outlet vanes.

• Do not splash or direct water at the unit.

• Do not expose the unit to direct sunlight during operation.

• Do not operate the unit without the air filter installed or when the front intake grille has been removed.

• Do not place any objects on the unit.

• Do not operate any combustion equipment near the unit’s airflow area.

• Do not sit or step on the unit, you may fall down accidentally.

• Do not touch the sharp aluminium fin, sharp parts may cause injury.


• Pay attention to any damages on the unit caused by extensive usage.

• Ventilate the room occasionally where the unit is installed.

AIR CONDITIONER OPERATION

3

Open the control panel cover.

Main Control Knob.

Set to LOW COOL or HIGH COOL as desired. (FAN setting operates the fan

only.)

Caution: If the main control knob is turned off or changed to a fan setting from

a cooling operation setting, WAIT at least 3 minutes before resetting

to cooling operation.

Thermostat Control Knob.

For a room that is too warm, set the control knob to a clockwise direction.

If the room is too cool, set the control knob to a counter clockwise direction.

*

NOTE:

 Usually 6~7 is the recommended setting position.

Air Swing Switch

(Airflow direction adjustment Side-to-Side)

To obtain a fix airflow direction, set the air swing switch to “ON” for the vanes to

swing from side to side until the desired flow direction is reached, then switch it to

“OFF”.

For continuous side-to-side air circulation, set the air swing switch to “ON”.

1

2

NOTE:

Recommended setting

3

4

Stops all

operation

High fan speed

with cooling

operation

REMOVAL OF FRONT GRILLE

1

Remove the front intake grille.

Pull up the front intake grille about 90° and slide it slightly to the left

to unhook the tabs. Unhook string for intake grille.

Do not raise the front intake grille any higher

than 90° to the unit or damage to the tabs may

occur.

2

Remove the air filter.

Tilt up and pull out the air filter by the holder.

3

Remove the front grille.

Air filter

WALL

56cm

Less than 24cm

Fence

or likewise

60.6cm

CAUTION

WARNING

CAUTION

WARNING

CAUTION

CEILING

Over 15cm

Before operating the unit, read these operating instructions thoroughly and keep

them for future reference.

Over 15cm

37.5cm

Over

 50cm

Switch off the breaker and set the main control knob to the OFF position before

plugging the power plug into an electrical outlet.

CAUTION

CAUTION POINT DURING INSTALLATION

When  installing  air-conditioner  at  glass  window  or  thin

partition,  fix  the  vertical  &  side  supporting  bar  to  the

concrete wall in order to support the weight of the air-

conditioner  and  reduce  the  vibration  that  is  being

transferred to the glass window or thin partition.

This can minimize the noise problem caused by improper

installation.

• Proposed to use 1/8” x 1-1/4” “angle-

aluminium” for installation frame and

side supporting bar.

fixed to concrete wall

Vertical

supporting bar

Glass window

or thin partition

Side

supporting

bar

External view of air-conditioner

installation

concrete wall

 

WARNING

• Do not modify the length of the power cord or use an extension cord.

• Do not touch or operate with wet hands.

• Do not modify or damage the cord.

• Do not turn on the unit by inserting the power plug. Do not switch off the unit by pulling out the power plug.

• Avoid an extended period of direct airflow.

• Do not insert your fingers or other objects into the unit, rotating parts may cause injury.

• Do not try to repair the unit yourself. Engage authorized dealer or specialist for installation.

• Plug in the P.S. cord properly before operating and use a specified power cord.

• If abnormal conditions (burnt smell, etc.) occur, switch off and unplug the unit.

• Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than 