Please observe these following safety precautions when using your air conditioner.
•
Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.
Improper grounding could cause electric shock.
Gas leaks near the unit could cause fire.
Ensure that the drainage piping is connected properly.
Otherwise, water will leak out.
This sign warns of risk of death or serious injury.
1
SAFETY PRECAUTIONS
INSTALLATION PRECAUTIONS
OPERATION PRECAUTIONS
• Do not modify the length of the power cord or use an extension cord.
• Do not touch or operate with wet hands. Do not modify or damage the cord.
• Do not turn on the unit by inserting the power plug. Do not switch off the unit by pulling out the
power plug.
• Avoid an extended period of direct airflow.
• Do not insert your fingers or other objects into the unit, rotating parts may cause injury.
• Do not try to repair the unit yourself.
• Plug in properly before operating and use a specified power cord.
• If abnormal conditions (burnt smell, etc.) occur, switch off and remove the power plug.
Main control panel
2
PART IDENTIFICATION
MAIN UNIT
Air inlet louvre
Air filter
(behind the front intake grille)
Cabinet
Front intake grille
Front grille
Power cord
Vertical airflow direction vane
(Airflow direction adjustment up-down).
The vertical airflow direction vane is
controlled by positioning the vane to
discharge the air upwards, downwards
or straight out.
Air Swing Switch
OFF
Stops the operation of Air Swing.
ON
Air Swing is in operation. (Only
for LOW COOL and HIGH COOL
operation.)
OPERATION CONDITIONS
Use the air conditioner under the following conditions:
• Operating temperature range.
NOTE:
Humidity may exceed 90%
Indoor side
Outdoor side
D.B.T.
W.B.T.
D.B.T.
W.B.T.
Max. Temperature
32
23
43
26
Min. Temperature
21
15
21
15
(unit in °C)
D.B.T.: Dry Bulb Temperature
W.B.T.: Wet Bulb Temperature
Continuous operation at over 90% high humidity may create condensation and result in waterdrops on the
intake and outlet vanes.
4
AIR CONDITIONER INSTALLATION
• When installing, use the nearest power outlet. Make sure the power outlet is easy to
reach so you can quickly disconnect your air conditioner in case of emergency.
• Ensure that the air conditioner is well supported, securely fastened, easily reachable
and not obstructed.
• Avoid locations with: salty or sulphurous air, draughts, dampness and flammable gas.
• If you install the drainage system, be sure to channel the condensed water to a suitable
location.
• Covers, obstructions and unsteady support may cause excessive operating noise and vibration.
• The rear end of the air conditioner is splash proof. You need not shield or cover it.
Dimension
• There should not be any obstacles surrounding the
unit.
• Prepare an installation hole slightly bigger than the
cabinet size.
• Left and right sides of the unit should be at least
15cm away from the wall.
CHOOSING THE INSTALLATION LOCATION
PREPARATIONS BEFORE INSTALLATION
For
decreased
cooling
For
increased
cooling
Low fan speed operation
(without cooling)
High fan speed operation
(without cooling)
Low fan speed with
cooling operation
Main Control Knob
Thermostat Control Knob
This sign warns of injury or damage to property.
• Do not use the unit for other purposes, than its intended use.
• Do not remove the power plug by pulling the cord.
• Do not block the air intake and outlet vanes.
• Do not splash or direct water at the unit.
• Do not expose the unit to direct sunlight during operation.
• Do not operate the unit without the air filter installed or when the front intake grille has been removed.
• Do not place any objects on the unit.
• Do not operate any combustion equipment near the unit’s airflow area.
• Do not sit or step on the unit, you may fall down accidentally.
• Do not touch the sharp aluminium fin, sharp parts may cause injury.
•
• Pay attention to any damages on the unit caused by extensive usage.
• Ventilate the room occasionally where the unit is installed.
•
AIR CONDITIONER OPERATION
3
Open the control panel cover.
Main Control Knob.
Set to LOW COOL or HIGH COOL as desired. (FAN setting operates the fan
only.)
Caution: If the main control knob is turned off or changed to a fan setting from
a cooling operation setting, WAIT at least 3 minutes before resetting
to cooling operation.
Thermostat Control Knob.
•
For a room that is too warm, set the control knob to a clockwise direction.
•
If the room is too cool, set the control knob to a counter clockwise direction.
*
NOTE:
Usually 6~7 is the recommended setting position.
Air Swing Switch
(Airflow direction adjustment Side-to-Side)
To obtain a fix airflow direction, set the air swing switch to “ON” for the vanes to
swing from side to side until the desired flow direction is reached, then switch it to
“OFF”.
For continuous side-to-side air circulation, set the air swing switch to “ON”.
1
2
NOTE:
Recommended setting
3
4
Stops all
operation
High fan speed
with cooling
operation
REMOVAL OF FRONT GRILLE
1
Remove the front intake grille.
Pull up the front intake grille about 90° and slide it slightly to the left
to unhook the tabs. Unhook string for intake grille.
Do not raise the front intake grille any higher
than 90° to the unit or damage to the tabs may
occur.
2
Remove the air filter.
Tilt up and pull out the air filter by the holder.
3
Remove the front grille.
Air filter
WALL
56cm
Less than 24cm
Fence
or likewise
60.6cm
CAUTION
WARNING
CAUTION
WARNING
CAUTION
CEILING
Over 15cm
Before operating the unit, read these operating instructions thoroughly and keep
them for future reference.
Over 15cm
37.5cm
Over
50cm
Switch off the breaker and set the main control knob to the OFF position before
plugging the power plug into an electrical outlet.
CAUTION
CAUTION POINT DURING INSTALLATION
When installing air-conditioner at glass window or thin
partition, fix the vertical & side supporting bar to the
concrete wall in order to support the weight of the air-
conditioner and reduce the vibration that is being
transferred to the glass window or thin partition.
This can minimize the noise problem caused by improper
installation.
• Proposed to use 1/8” x 1-1/4” “angle-
aluminium” for installation frame and
side supporting bar.
fixed to concrete wall
Vertical
supporting bar
Glass window
or thin partition
Side
supporting
bar
External view of air-conditioner
installation
concrete wall
WARNING
• Do not modify the length of the power cord or use an extension cord.
• Do not touch or operate with wet hands.
• Do not modify or damage the cord.
• Do not turn on the unit by inserting the power plug. Do not switch off the unit by pulling out the power plug.
• Avoid an extended period of direct airflow.
• Do not insert your fingers or other objects into the unit, rotating parts may cause injury.
• Do not try to repair the unit yourself. Engage authorized dealer or specialist for installation.
• Plug in the P.S. cord properly before operating and use a specified power cord.
• If abnormal conditions (burnt smell, etc.) occur, switch off and unplug the unit.
• Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than
the specified type may cause product damage, burst and injury etc.
Thank you for
buying Panasonic
Air Conditioner
F568442_EN
1/20/09, 5:29 PM
1