Panasonic CS-Z12RKR Operating Instructions Manual Download Page 1

Operating Instructions
Air Conditioner

Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating 
instructions thoroughly and keep them for future 
reference. 

English

Model No.
Indoor Unit

Outdoor Unit

CS-Z7RKR
CS-Z9RKR
CS-Z12RKR
CS-Z15RKR
CS-Z18RKR
CS-Z21RKR
CS-Z24RKR
CS-Z28RKR

CU-Z7RKR
CU-Z9RKR
CU-Z12RKR
CU-Z15RKR
CU-Z18RKR
CU-Z21RKR
CU-Z24RKR
CU-Z28RKR

Operating Instructions

Air Conditioner

F570018

i AUTO-X

POWERFUL

F570018-SA0815-1.indb   1

F570018-SA0815-1.indb   1

17/08/2015   2:42:07 PM

17/08/2015   2:42:07 PM

Process Black

Process Black

Summary of Contents for CS-Z12RKR

Page 1: ...unit read these operating instructions thoroughly and keep them for future reference English Model No Indoor Unit Outdoor Unit CS Z7RKR CS Z9RKR CS Z12RKR CS Z15RKR CS Z18RKR CS Z21RKR CS Z24RKR CS Z28RKR CU Z7RKR CU Z9RKR CU Z12RKR CU Z15RKR CU Z18RKR CU Z21RKR CU Z24RKR CU Z28RKR Operating Instructions Air Conditioner F570018 i AUTO X POWERFUL ...

Page 2: ... you get to enjoy instant fast cooling satisfaction on a hot day and cooling comfort that goes on all day long Applicable for horizontal flap AUTO setting ECONAVI INVERTER The Perfect Energy Saving Technology ECONAVI detects where energy is normally wasted and adjusts cooling heating power depending on room conditions and activity levels Then INVERTER leverages ECONAVI sensor data and varies compr...

Page 3: ... C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from the remote control receiver of the indoor unit The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subject to change without notice for future improvement Table of contents Safety pre...

Page 4: ...nstallation Instruction table Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock ...

Page 5: ...rvicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment...

Page 6: ...te room cooling Set temperature i AUTO X 1 C Max 4 hours After max 4 hours the set temperature is shifted according to activity detection Fan speed is fixed at AUTO fan speed selection is prohibited During unit is off press i AUTO X will turn on the unit with i AUTO X mode i AUTO X mode can be cancelled by pressing the respective button again MODE To select operation mode AUTO For your convenience...

Page 7: ...nt depends on human activity sensor If manual is set the horizontal and vertical flap are fixed at the predetermined position Do not adjust the flap by hand To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times ON OFF SET CANCEL 1 2 3 TIMER CANCEL 3 TIMER 1 2 3 1 Select ON or OFF timer Example OFF at 22 00 Each time pressed OFF Cancel 2 Set...

Page 8: ... ECONAVI Note AIR SWING When manual AIR SWING is selected the ECONAVI operations will be cancelled The unit will start to initialise for approximately 1 minute The human activity sensor and the sunlight sensor will start to detect Human activity sensor operation Low activity Normal activity Human Mode Set temperature High activity Absent ECONAVI Detecting human presence and activity the unit contr...

Page 9: ...t as non heat source movement if a human stays motionless for certain period of time Do not place large objects near the sensor and keep away heating units or humidifier from the sensor s detection area They may cause sensor malfunction i AUTO X Low activity Normal activity Human Mode Set temperature High activity Absent i AUTO X Fast cooling to maximum of 4 hours the unit continue to provide cool...

Page 10: ...2 Close down 3 Press both ends of the front panel 4 For CS Z18RKR CS Z21RKR CS Z24RKR CS Z28RKR Press at center of the front panel nanoe G Generator Every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Rep...

Page 11: ...ave collected around the front panel grilles and wall surrounding the unit after extended use The dust accumulation is due to air purification effect of negative ions from nanoe G Remove the dust regularly with a clean dampened cloth Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently Set the temperature correctly Close all doors an...

Page 12: ... in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by t...