background image

CS-WU12VKYF series
CS-WU18VKYF series
CS-WU18VKYLF series
CS-WU24VKYF series

CU-WU12VKYF series
CU-WU18VKYF series
CU-WU18VKYLF series
CU-WU24VKYF series

ACXF55-22480-AC

English

Operating Instructions
Air Conditioner

Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, please read these operating 
instructions thoroughly and keep them for future 
reference. 

C

SLEEP/

SLEEP/
POWERFUL

POWERFUL

nanoe-G

nanoe-G
PURIFIER

PURIFIER

C

M

Y

CM

MY

CY

CMY

K

ACXF55-2248̲OL.ai   1   1/27/2020   7:12:58 PM

ACXF55-2248̲OL.ai   1   1/27/2020   7:12:58 PM

Summary of Contents for CS-WU12VKYF Series

Page 1: ...tructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C SLEEP SLEEP POWERFUL POWERFUL nanoe G nanoe G PURIFIER PURIFIER C M Y CM MY CY CMY K ACXF55 2248 OL ai 1 1 27 2020 7 12 58 PM ACXF55 2248 OL ai 1 1 27 2020 7 12 58 PM ...

Page 2: ...C M Y CM MY CY CMY K ACXF55 2248 OL ai 2 1 27 2020 7 13 10 PM ACXF55 2248 OL ai 2 1 27 2020 7 13 10 PM ...

Page 3: ...than room temperature Default set temperature is 24 C in COOL mode as per country guidelines Use remote control within 7 m from the remote control receiver of the indoor unit FAN DRY 7m 1 3 2 POWERFUL QUIET nanoe G 2 1 3 Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 C M Y CM MY CY CMY K ACXF55 2248 OL ai 3 1 27 2020 7 13 12 PM ...

Page 4: ...are that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handing will cause leakage electric shock or fire Confirm with authorised dealer or s...

Page 5: ...dels Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut on the outdo...

Page 6: ...their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be performed...

Page 7: ...ance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall include bu...

Page 8: ...ion When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing The refrig...

Page 9: ...rigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recov...

Page 10: ...set To maximise comfort while sleeping This operation provides you with a comfortable environment while sleeping by gradually increase the set temperature 1 C after every 3 hours operation The unit is turned off after 8 hours Can be cancelled by pressing the respective button again SLEEP POWERFUL To switch between POWERFUL and QUIET mode POWERFUL To reach set temperature quickly SLEEP POWERFUL Thi...

Page 11: ... the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick guide Auto Restart Control If power is resumed after a power failure the operation will restart automatically after a period of time with previous operation mode and airflow direction This control is not applicable when TIMER is set To ...

Page 12: ...nts Use Auto OFF ON button to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents COOL 8 C For extended non use Activate nanoe G operation for 2 3 hours as an alternative to remove moisture left in the internal parts thoroughly to prevent mould growth Turn off the power supply and unplug Remove the rem...

Page 13: ...ot functioning properly The unit stops and the TIMER indicator blinks Use remote control to retrieve error code Press for 5 seconds Press for 5 seconds to quit checking Press until you hear 4 beep sound then write down the error code Turn the unit off and reveal the error code to authorised dealer 2 1 3 4 operation but if problem persist please consult authorised dealer with error code For certain...

Page 14: ...nel by lifting Intake Grille Follow the below Instructions 4 Air Swing Horizontal Airflow Set vane position to be straight For applicable Model 5 Fan speed Maximum 1 2 1 2 For Half Load QUIET CLEAN 1 2 1 2 Indication for Half load Indication for Full load POWER TIMER nanoe G PURIFIER SLEEP POWERFUL POWER TIMER nanoe G PURIFIER SLEEP POWERFUL THREE LEDs FROM BOTTOM STARTS BLINKING TWO LEDs FROM BOT...

Page 15: ...asonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breakage Refer t...

Page 16: ...source there is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions C M Y CM MY CY CMY K ACXF55 2248 OL ai 16 ...

Reviews: