Panasonic CS-TE20TKEW Operating Instructions Manual Download Page 1

Nederlands

Italiano

Deutsch

Español

Français

English

ACXF55-04100

Model No.
Indoor Unit 

Outdoor Unit

CS-TE20TKEW

CS-TE25TKEW

CS-TE35TKEW

CS-TE42TKEW

CS-TE50TKEW

CS-TE60TKEW

CS-TZ20TKEW

CS-TZ25TKEW

CS-TZ35TKEW

CS-TZ42TKEW

CS-TZ50TKEW

CS-TZ60TKEW

CS-TZ71TKEW

CS-MTZ16TKE 

Outdoor Unit 
Single Split (R410A)

CU-TE20TKE

CU-TE25TKE

CU-TE35TKE

CU-TE42TKE

CU-TE50TKE

CU-TE60TKE

Single Split (R32)

CU-TZ20TKE

CU-TZ25TKE

CU-TZ35TKE

CU-TZ42TKE

CU-TZ50TKE

CU-TZ60TKE

CU-TZ71TKE

Multi Split (R410A)

CU-3E18PBE

CU-4E23PBE

CU-4E27PBE

CU-5E34PBE

CU-2E12SBE

CU-2E15SBE

CU-2E18SBE

CU-3E23SBE

CU-2RE15SBE

CU-2RE18SBE

CU-3RE18SBE

Multi Split (R32)

CU-2Z35TBE

CU-2Z41TBE

CU-2Z50TBE

CU-3Z52TBE

CU-3Z68TBE

CU-4Z68TBE

CU-4Z80TBE

CU-5Z90TBE

CU-2TZ41TBE

CU-2TZ50TBE

CU-3TZ52TBE

Operating Instructions

Air Conditioner

 

Operating Instructions
Air Conditioner

2-15

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read 
by the installer before installation.
Remote control is packaged in the indoor unit and removed 
by the installer before installation.

Comment utiliser l’appareil
Climatiseur

16-29

Avant d’utiliser l’appareil, veuillez lire ce mode d’emploi dans 
son intégralité et conservez-le pour toute référence ultérieure.
Le manuel d’installation inclus doit être conservé et lu par 
l’installateur avant l’installation.
La télécommande est emballée dans l’unité intérieure et 
retirée par l’installateur avant l’installation.

Instrucciones de funcionamiento
Climatizador de aire

30-43

Antes de utilizar la unidad, sírvase leer atentamente estas 
instrucciones de funcionamiento y conservarlas para futuras 
consultas.
El instalador debe guardar y leer las Instrucciones de 
instalación incluidas antes de la instalación.
El mando a distancia viene embalado en la unidad interior y 
debe ser retirado por el instalador antes de la instalación.

Bedienungsanleitung
Klimagerät

44-57

Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese 
Bedienungsanleitung aufmerksam durch und bewahren Sie 
sie als künftige Referenz auf.
Das mitgelieferte Installationshandbuch sollte aufbewahrt und 
vor der Installation vom Installateur gelesen werden.
Die Fernbedienung ist im Innengerät verpackt und wird vor 
der Installation durch den Installateur entfernt.

Istruzioni di funzionamento
Condizionatore d’aria

58-71

Prima di utilizzare l’unità, leggere attentamente le istruzioni 
e conservare questo opuscolo per potervi fare riferimento in 
futuro.
Le istruzioni per l’installazione fornite in dotazione 
devono essere conservate e lette dall’installatore prima 
dell’installazione.
Il telecomando si trova nell’unità interna e deve essere 
rimosso dall’installatore prima dell’installazione.

Handleiding
Airconditioner

72-85

Lees voor u het apparaat gebruikt deze gebruikshandleiding 
grondig en bewaar deze voor toekomstig gebruik.
De bijgevoegde installatiehandleiding moet door de 
installateur worden bewaard en gelezen vóór de installatie.
De afstandsbediening is in de binnenunit verpakt en moet 
vóór de installatie door de installateur worden verwijderd.

ACXF55-04100_01EN.indd   1

ACXF55-04100_01EN.indd   1

12/19/2016   5:29:53 PM

12/19/2016   5:29:53 PM

Summary of Contents for CS-TE20TKEW

Page 1: ...e et retir e par l installateur avant l installation Instrucciones de funcionamiento Climatizador de aire 30 43 Antes de utilizar la unidad s rvase leer atentamente estas instrucciones de funcionamien...

Page 2: ...ethods Use remote control within 8 m from the remote control receiver of the indoor unit Quick Guide Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batte...

Page 3: ...oses only and may differ from the actual unit They are subject to change without notice for future improvement B Basic operation 1 Press to select the desired mode DRY AUTO HEAT COOL 2 Press to start...

Page 4: ...lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the...

Page 5: ...h Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD to prevent electric shock or fire To prevent overheating fire or electric shock Insert the power plug properly Dust on the power plu...

Page 6: ...ng and flare nuts on the outdoor unit side The R32 flare nut and pipe on the outdoor unit side can also be used for a R410A model Models that use refrigerant R32 and R410A have a different charging po...

Page 7: ...it to avoid injury Do not place a vase or water container on the unit Water may enter the unit and degrade the insulation This may cause an electric shock Do not open window or door for long time duri...

Page 8: ...t the lowest fan speed AUTO FAN Indicator POWER Green TIMER Orange Do not adjust the flap by hand To adjust airflow direction To adjust airflow direction AIR SWING Upper direction CS TE TZ20 25 35 42T...

Page 9: ...ck set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times How...

Page 10: ...on mode other than HEAT is selected the indoor unit stops and the POWER indicator blinks COOL Provides efficient comfort cooling to suit your needs DRY Unit operates at low fan speed to give a gentle...

Page 11: ...ature C F Multi split outdoor unit 3 DBT WBT COOL Max 43 109 4 26 78 8 Min 16 60 8 11 51 8 HEAT Max 24 75 2 18 64 4 Min 10 14 0 11 12 2 DBT Dry bulb temperature WBT Wet bulb temperature 1 CU TE20TKE C...

Page 12: ...ge from the drain pipe Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sun...

Page 13: ...he unit Dusts accumulated on the wall Due to air circulation or static electricity generated by the air conditioner Some types of wall paper may collect dusts easily recommended to clean the area arou...

Page 14: ...and outlet vents Use Auto OFF ON button to select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COO...

Page 15: ...al indoor operating unit or standby units H 41 Abnormal wiring or piping connection H 59 Eco sensor abnormality H 64 Outdoor high pressure sensor abnormality H 67 nanoe abnormality H 70 Light sensor a...

Reviews: