14. Servicing
Mode
14.1 Auto Off/On Button
Auto OFF/ON
Button Pressed
Auto OFF/ON
Button Pressed
5 sec
Auto Operation
Test Run Operation
(Forced Cooling Operation)
Stop
Beep
1 AUTO OPERATION MODE
The Auto Operation will be activated immediately once the Auto OFF/ON button is pressed. This operation
can be used to operate air conditioner with limited function if remote control is misplaced or malfunction.
2 TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run Operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5
seconds. A “beep” sound will be heard at the fifth seconds, in order to identify the starting of this operation.
The Auto OFF/ON button may be used together with remote control to set / change the advance setting of air
conditioner operation.
3 REMOTE CONTROL NUMBER SWITCH MODE
The Remote Control Number Switch Mode will be activated if the Auto OFF/ON button is pressed
continuously for more than 11 seconds (3 “beep” sounds will occur at 11
th
seconds to identify the Remote
Control Number Switch Mode is in standby condition), press “AC Reset” button and then press any button at
remote control to transmit and store the desired transmission code to the EEPROM.
There are 4 types of remote control transmission code could be selected. The indoor unit will only operate
when received signal with same transmission code from remote control. This could prevent signal
interference when there are 2 or more units installed nearby together.
To change remote control transmission code, short or open jumpers at the remote control printed circuit
board.
Remote Control Printed Circuit Board
Jumper A (J1)
Jumper B (D2)
Remote Control No.
Short Open
A
(Default)
Open (cut jumper)
Open
B
Short Short
with
diode C
Open (cut jumper)
Short with diode
D
* Diode is field supplied. Part number: SOD-323 IN4148WS / LMDL914T1G
4 REMOTE CONTROL RECEIVING SOUND OFF/ON MODE
The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed
continuously for more than 16 seconds (4 “beep” sounds will occur at 16th seconds to identify the Remote
Control Receiving Sound OFF/ON Mode is in standby condition) and press “AC Reset” button at remote
control.
Press Auto OFF/ON button to toggle remote control receiving sound.
- Short “beep”: Turn OFF remote control receiving sound.
- Long “beep”: Turn ON remote control receiving sound.
After Auto OFF/ON button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON
Mode is restarted.
Summary of Contents for cs-s9pkv
Page 12: ...12 4 Dimensions 4 1 Indoor Unit 4 1 1 CS S9PKV CS S12PKV...
Page 13: ...13 4 1 2 CS S18PKV CS S24PKV CS S28PKV...
Page 14: ...14 4 2 Outdoor Unit 4 2 1 CU S9PKV 4 2 2 CU S12PKV 542...
Page 15: ...15 4 2 3 CU S18PKV CU S24PKV...
Page 16: ...16 4 2 4 CU S28PKV...
Page 17: ...17 5 Refrigeration Cycle Diagram 5 1 CS S9PKV CU S9PKV CS S12PKV CU S12PKV...
Page 18: ...18 5 2 CS S18PKV CU S18PKV CS S24PKV CU S24PKV...
Page 19: ...19 5 3 CS S28PKV CU S28PKV...
Page 20: ...20 6 Block Diagram 6 1 CS S9PKV CU S9PKV...
Page 21: ...21 6 2 CS S12PKV CU S12PKV...
Page 24: ...24 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS S9PKV CS S18PKV CS S24PKV...
Page 26: ...26 7 1 3 CS S28PKV...
Page 31: ...31 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS S9PKV CS S18PKV CS S24PKV...
Page 32: ...32 8 1 2 CS S12PKV...
Page 33: ...33 8 1 3 CS S28PKV...
Page 35: ...35 8 2 2 CU S12PKV...
Page 39: ...39 9 1 1 2 CS S12PKV...
Page 41: ...41 9 1 5 Human Activity Sensor Printed Circuit Board...
Page 42: ...42 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU S9PK...
Page 43: ...43 9 2 1 2 CU S12PK...
Page 44: ...44 9 2 1 3 CU S18PK CU S24PK...
Page 45: ...45 9 2 1 4 CU S28PK...
Page 46: ...46 9 2 2 Noise Filter Printed Circuit Board 9 2 2 1 CU S9PKV...
Page 47: ...47 9 2 2 2 CU S28PKV...
Page 51: ...51...
Page 60: ...60...
Page 121: ...121 Figure 3 Figure 4 16 1 1 3 To Remove Discharge Grille Figure 5...
Page 123: ...123 Figure 9 Figure 10...
Page 125: ...125 16 2 1 3 To Remove Power Electronic Controller Figure 13 Figure 14 Figure 15...
Page 127: ...127 Figure 19 Figure 20 Figure 21...