background image

6

 Safety precautions

WARNING

Precaution for appliance 

fi

 lled 

with R32

Pay careful attention to the following 

points when operating the appliances 

and dealing with different refrigerants.

The appliance shall be installed, 

and/or operated in a room with 

fl

 oor area larger than Amin (m²) 

and keep away from ignition 

sources, such as heat/sparks/

open 

fl

 ame or hazardous areas 

such as gas appliances, gas 

cooking, reticulated gas supply 

systems or electric cooking 

appliances, etc. (Refer to Table 

A of Installation instructions table 

for Amin (m²))
Be aware that refrigerant may 

not contain an odour, highly 

recommended to ensure suitable 

fl

 ammable refrigerant gas 

detectors are present, operating 

and able to warn of a leak.
Since the working pressure is 

higher than that of refrigerant 

R22 models, some of the piping 

and installation and service tools 

are special.

Especially, when replacing a 

refrigerant R22 model with a new 

refrigerant R32 model, always 

replace the conventional piping 

and 

fl

 are nuts with the R32 and 

R410A piping and 

fl

 are nuts on 

the outdoor unit side.

The R32 

fl

 are nut and pipe on 

the outdoor unit side can also be 

used for a R410A model.

Models that use refrigerant R32 

and R410A have a different 

charging port thread diameter to 

prevent erroneous charging with 

refrigerant R22 and for safety.

Therefore, check beforehand. 

[The charging port thread 

diameter for R32 and R410A is 

12.7 mm (1/2 inch).]
Be extra careful so that foreign 

matter (oil, water, etc.) does not 

enter the piping.

Also, when storing the piping, 

securely seal the opening by 

pinching, taping, etc. (Handling 

of R32 is similar to R410A.)

This appliance shall be stored in 

a well ventilated area.

This appliance shall be stored 

in a room without continuously 

operating open 

fl

 ames and 

ignition sources.
This appliance shall be stored 

so as to prevent mechanical 

damage from occurring.
Do not use means to accelerate 

the defrosting process or 

to clean, other than those 

recommended by manufacturer. 

Any un

fi

 t method or using 

incompatible material may cause 

product damage, burst and 

serious injury.
Do not pierce or burn as the 

appliance is pressurized. Do not 

expose the appliance to heat, 

fl

 ame, sparks, or other sources 

of ignition. Else it may explode 

and cause injury or death.

Summary of Contents for CS-LZ25TKE

Page 1: ... av installatören före installationen Bruksanvisninger Klimaanlegg 30 43 Les bruksanvisningen nøye før du bruker denne enheten og oppbevar den for fremtidig bruk Installatøren bør oppbevare og lese de medfølgende installasjonsinstruksene før installasjon Fjernkontrollen skal pakkes inn i innendørsenheten og fjernes av installatøren før installasjon Käyttöohjeet Ilmastointilaite 44 57 Lue nämä käyt...

Page 2: ...and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm SET Use remote control within 8 m from the remote control receiver of the indoor unit AIR CONDITIONER ON OFF SET TIMER CANCEL TEMP FAN SPEED i f SET TEMP 2 control receiver of the indoor unit AIR SWING AIR SWING OFF ON MODE AIR CONDITIONER ON OFF TIMER CANCEL FAN SPEED AIR SWIN...

Page 3: ...k you for purchasing Panasonic Air Conditioner WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition CAUTION This symbol shows that the Operation Instructions should be read carefully CAUTION This symbol shows that there is information included in the Operation Instruction...

Page 4: ...r lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstal...

Page 5: ...rcuit Breaker ELCB or Residual Current Device RCD to prevent electric shock or fire To prevent overheating fire or electric shock Insert the power plug properly Dust on the power plug should be periodically wiped with a dry cloth Stop using the product if any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples...

Page 6: ...ing and flare nuts on the outdoor unit side The R32 flare nut and pipe on the outdoor unit side can also be used for a R410A model Models that use refrigerant R32 and R410A have a different charging port thread diameter to prevent erroneous charging with refrigerant R22 and for safety Therefore check beforehand The charging port thread diameter for R32 and R410A is 12 7 mm 1 2 inch Be extra carefu...

Page 7: ...nit to avoid injury Do not place a vase or water container on the unit Water may enter the unit and degrade the insulation This may cause an electric shock Do not open window or door for long time during operation it may lead to inefficient power usage and uncomfortable temperature changes Prevent water leakage by ensuring drainage pipe is Connected properly Kept clear of gutters and containers or...

Page 8: ...he indoor fan speed is automatically adjusted according to the operation mode To have low noise priority operation select the lowest fan speed To adjust fan speed AUTO FAN To switch between powerful quiet Do not adjust the flap by hand Do not insert finger into the air flow outlet to prevent injury Maintain indoor temperature at 8 15 C Fan switches to high fan speed automatically This operation ov...

Page 9: ...To cancel ON or OFF timer press or to select respective or then press If timer is cancelled manually or due to power failure you can restore the timer again by pressing or to select respective or then press SET The nearest timer setting will be displayed and will activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please...

Page 10: ...perature range may save energy HEAT 20 0 C 24 0 C 68 F 75 F COOL 26 0 C 28 0 C 79 F 82 F Air flow direction In COOL DRY mode If AUTO is set the flap swings left right and up down automatically In HEAT mode If AUTO is set the horizontal flap is fixed at the predetermined position The vertical flap swings left right after the temperature rises Auto restart control If power is resumed after a power f...

Page 11: ...oid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Insert into the unit Attach air filter Remove air filter Front panel Wash gently and dry Remove the front panel Close it securely Raise Pull out 1 2 Insert and push in at both side 1 Press both ends of the front panel 3 Close down 2 Indoor unit Air Purifying Filter ...

Page 12: ...ccumulated on the wall Due to air circulation or static electricity generated by the air conditioner Some types of wall paper may collect dusts easily recommended to clean the area around the air conditioner frequently POWER indicator blinks and stops when operate COOL DRY mode The system has locked to operate in HEAT mode only Discoloration of some plastic parts Discoloration is subject to materi...

Page 13: ...nlet and outlet vents Use Auto OFF ON button to select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units are not going to be used for a long period of time Activate HEAT mode for 2 3 hours to remove moisture left in the internal parts thoroughly to prevent mou...

Page 14: ...nection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code H 39 Abnormal indoor operating unit or standby units Diagnostic display Abnormality Protection control H 41 Abnormal wiring...

Page 15: ...ling For more information about collection and recycling of old products and batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the items Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation Pb For business users in the European Union If you wish to discard electrical and electron...

Reviews: