background image

Split System Submittal Data

Indoor: 

CS-E24NKUA

Outdoor: 

CU-E24NKUA 

Wall Mounted Heat Pump

Job Name:

Approval:

Location:

Date:

Engineer:

Construction:

Submitted to:

Unit #:

Submitted by:

Drawing #:

Reference:

Power

V/PH/Hz

230/208/1/60

Refrigerant

Circuit Ampacity

(A)

20

Lbs. - R410a (outdoor unit)

Fuse Size, Max.

(A)

20

Control
Connection

Compressor

DC Rotary Inverter

Line Length, Max (ft.)

No. used

1

Lift Difference, Max (ft.)

Output Power

(W)

Line Size

(in. O.D. Discharge)         

1/4"

Line Size

(in. O.D. Suction)           

5/8"

Outdoor Unit

Fan type

Propeller

Dimensions

(in.)

Height

Width

Depth

Motor Type 

DC Motor ( 8 poles )  

Indoor Unit

(Uncrated)

11-7/16"

42-5/32"

9-9/32"

Output Power 

(W)

(Crated)

Airflow

CFM

Outdoor Unit

(Uncrated)

31-5/16"

34-15/32"

12-5/8"

(Crated)

Coil Type

Aluminum  ( Blue Coated )

Fin Type - Pipe Type

Corrugated Fin

Weight

Indoor

Outdoor

Rows - F.P.I

Net

(lbs.)

26

117

Face Area

(sq.ft)

Shipping

(lbs.)

Indoor Unit

Fan type

Cross Flow

Cooling

No. Speeds

5

Total Capacity

(BTU/H)

RPM

(High)

SEER

17.5

Motor Output

(W)

Dehumidification

(Pints/H)

CFM

(Hi / Med / Lo)

Amps

(A)

Indoor / 10.75Outdoor / 11.90

Indoor Sound Rating

(Hi) (dB-A)

Power Inputs

(W)

2350

Coil Type 

Aluminum Fin & Copper Tube

Outdoor Sound Rating

(dB-A)

Fin Type - Pipe Type

Slit Plate - Inner Rifled

Rows - F.P.I

Heating

Face Area

(sq.ft)

Total Capacity

(BTU/H)

Drain Connection Size

(in.)

HSPF

8.5

Amps

(A)

Indoor / 11.40Outdoor / 12.60

Features

Power Inputs

(W)

2500

Wireless Remote Controller Standard

Outdoor Sound Rating

(dB-A)

Wired Remote Controller ( CZ-RD516C ) Optional
Controls

Microprocessor

Operating Range

Remote Controller

LCD Wireless Type, Temp, Sensor Built In

Indoor Air Intake Temp.

Outdoor Air Intake Temp.

Temperature Control

IC Thermostat

Cooling

Maximum

90F DB/74F WB

115F DB

Air Louver

(Horizontal)

Manual

Minimum

60F DB/52F WB

0F DB

(Vertical)

Automatic

Heating

Maximum

86F DB/-F WB

75F DB/ 64F WB

Power Failure Automatic Restart

Built-In

Minimum

60F DB/-F WB

5F DB/-F WB

Self-Diagnosis

Built-In

Air Filter

Washable, Anti-Mold

49

24000

Performance Data @ ARI Standard Conditions (230/208V)

100

R410A

Electronic Expansion Valve

Flare

28800

Reviews: