22
Inner Diameter
mm
16
Drain Hose
Length mm
650
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 21
Indoor Heat
Exchanger
Size (W x H x L)
mm
810 x 315 x 25.4
Fin Material
Aluminium (Blue Coated)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 30 x 19
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
38.1 x 762 x 895.8:865.8
Material
Polypropelene
Air Filter
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
A
Nil
Thermostat
Electronic
Contol
Protection Device
Electronic Contol
DRY BULB
WET BULB
Maximum 32
23
Cooling
Minimum 16
11
Maximum 30
-
Indoor
Operation
Range
Heating
Minimum 16
-
Maximum 46
26
Cooling
Minimum 5
4
Maximum 24
18
Outdoor
Operation
Range
Heating
Minimum -15
-16
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
3.
Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C
5.
Specifications are subjected to change without prior notice for further improvement.
Summary of Contents for CS-E12NKR
Page 30: ...30 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 31: ...31 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E7NKR CS E9NKR CS E12NKR CS E15NKR ...
Page 32: ...32 5 1 2 CS E18NKR CS E21NKR CS E24NKR CS E28NKR ...
Page 34: ...34 5 2 3 CU E28NKR ...
Page 35: ...35 6 Refrigeration Cycle Diagram 6 1 CU E7NKR ...
Page 36: ...36 6 2 CU E9NKR CU E12NKR ...
Page 37: ...37 6 3 CU E15NKR CU E18NKR ...
Page 38: ...38 6 4 CU E21NKR ...
Page 39: ...39 6 5 CU E24NKR CU E28NKR ...
Page 40: ...40 7 Block Diagram 7 1 CU E7NKR CU E9NKR CU E12NKR ...
Page 41: ...41 7 2 CU E15NKR CU E18NKR CU E21NKR ...
Page 42: ...42 7 3 CU E24NKR ...
Page 43: ...43 7 4 CU E28NKR ...
Page 44: ...44 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 45: ...45 8 2 Outdoor Unit 8 2 1 CU E7NKR CU E9NKR CU E12NKR ...
Page 46: ...46 8 2 2 CU E15NKR CU E18NKR ...
Page 47: ...47 8 2 3 CU E21NKR ...
Page 48: ...48 8 2 4 CU E24NKR ...
Page 49: ...49 8 2 5 CU E28NKR ...
Page 50: ...50 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 51: ...51 9 2 Outdoor Unit 9 2 1 CU E7NKR CU E9NKR CU E12NKR ...
Page 52: ...52 9 2 2 CU E15NKR CU E18NKR ...
Page 53: ...53 9 2 3 CU E21NKR ...
Page 54: ...54 9 2 4 CU E24NKR ...
Page 55: ...55 9 2 5 CU E28NKR ...
Page 58: ...58 10 1 6 Human Activity Sensor Printed Circuit Board ...
Page 59: ...59 10 2 Outdoor Unit 10 2 1 CU E7NKR CU E9NKR CU E12NKR ...
Page 60: ...60 10 2 2 CU E15NKR CU E18NKR ...
Page 61: ...61 10 2 3 CU E21NKR CU E24NKR ...
Page 62: ...62 10 2 4 CU E28NKR ...
Page 63: ...63 10 2 5 Noise Filter Printed Board CU E21NKR ...
Page 108: ...108 16 3 Error Code Table ...
Page 109: ...109 ...
Page 140: ...140 17 1 1 3 To remove discharge grille ...
Page 141: ...141 17 1 1 4 To remove control board 17 1 1 5 To remove cross flow fan and indoor fan motor ...
Page 142: ...142 ...
Page 144: ...144 17 2 1 3 To remove power electronic controller ...
Page 146: ...146 ...
Page 201: ...201 19 2 5 CU E28NKR ...
Page 202: ...202 ...