PACKAGED AIR CONDITIONER

Model No.

(Ceiling suspended type)

CS-32TMJPL
CS-63TMJPL
CS-100TMJPL

INSTALLATION MANUAL

READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.

LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L’INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.

LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER 
ALGUNA DUDA.

PRIMA DELL’INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.

ÄÉÁÂÁÓÔÅ ÐÑÏÓÅÊÔÉÊÁ ÁÕÔÅÓ ÔÉÓ ÏÄÇÃÉÅÓ ÐÑÉÍ ÁÐÏ ÔÇÍ ÅÃÊÁÔÁÓÔÁÓÇ Å×ÅÔÅ ÁÕÔÏ 

ÔÏ ÅÃ×ÅÉÑÉÄÉÏ ÅÕÊÁÉÑÏ ÃÉÁ ÍÁ ÔÏ ÓÕÌÂÏÕËÅÕÅÓÔÅ ÓÔÏ ÌÅËËÏÍ.

LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.

LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.

Urban Multi Series

cover.fm  Page 1  Friday, September 14, 2001  11:09 AM

Summary of Contents for CS-100TMJPL

Page 1: ...ERENCE ULTERIEURE LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA PRIMA DELL INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI ÄÉÁÂÁÓÔÅ ÐÑÏÓÅÊÔÉÊÁ ÁÕÔÅÓ ÔÉÓ ÏÄÇÃÉÅÓ ÐÑÉÍ ÁÐÏ ÔÇÍ ÅÃÊÁÔÁÓÔÁÓÇ Å ÅÔÅ ÁÕÔÏ ÔÏ ÅÃ ÅÉÑÉÄÉÏ ÅÕÊÁÉÑÏ ÃÉÁ ÍÁ ÔÏ ÓÕÌÂÏÕËÅÕÅÓÔÅ Ó...

Page 2: ...rm installation work in accordance with this installation manual Improper installation may result in water leakage electric shocks or fire Be sure to use only the specified accessories and parts for installation work Failure to use the specified parts may result in water leakage electric shocks fire or the unit falling Install the air conditioner on a foundation strong enough to withstand the weig...

Page 3: ...hen Plastic parts may deteriorate and fall off or result in water leakage b where corrosive gas such as sulfurous acid gas is produced Corroding copper pipes or soldered parts may result in refrigerant leakage c near machinery emitting electromagnetic waves Electromagnetic waves may disturb the operation of the control system and result in a malfunction of the equipment d where flammable gases may...

Page 4: ...stallation in a commercial and light industrial environ ment If installed as a household appliance it could cause electromagnetic interference 2 2 ACCESSORIES Check if the following accessories are included with your unit 2 3 OPTIONAL ACCESSORIES These are two types of remote controllers wired and wireless Select a remote controller according to customer request and install in an appropriate place...

Page 5: ...tenance and service Where piping between indoor and outdoor units is possible within the allowable limit Refer to the instal lation manual for the outdoor unit Keep the indoor and outdoor units power cable and transmission wiring at least 1 m from TVs and radios to prevent distorted pictures and static Depending on the type and source of the electrical waves static may be heard even when more than...

Page 6: ...s of indoor unit suspension bolt piping hole drain piping hole and electric wire hole position Refer to Fig 2 Model A B C D E F G CS 32TMJPL 960 920 390 375 310 400 375 CS 63TMJPL 1160 1120 490 475 410 500 475 CS 100TMJPL 1400 1360 610 595 530 620 595 30 30 300 2500 or higher from the floor For installation in high places Air inlet Air outlet Obstruction Floor Required service space Length mm Fig ...

Page 7: ...de on each side for less than 10 mm Refer to Fig 6 and 7 Remove two hanger bracket fixing bolts M5 on the rear side Detach the hanger bracket by pulling backwards Refer to Fig 7 4 Set the suspension bolt Use W3 8 or M8 M10 size suspension bolts Adjust the distance from the unit to the ceiling slab beforehand Refer to Fig 8 NOTE All the above parts are part to be procured in the field Fig 3 Fig 4 A...

Page 8: ...ight This is necessary to prevent any forward and back deviance in the main body of the indoor unit Refer to Fig 10 5 When hanging the indoor unit main body be sure to use a level or a plastic tube with water in it to make sure the drain piping is set either level or slightly tilted in order to ensure proper drainage Refer to Fig 11 A When the drain piping is tilted to the right or to the right an...

Page 9: ...e of the piping using scissors and attach As when before removing the top penetration lid secure the lead lines for the swing motor and ther mistor by passing them through the cramp part on the top penetration lid Refer to Fig 12 15 When doing this block any gaps between the piping penetration lid and the pipes using putty to prevent dust from entering the indoor unit CAUTION Use a pipe cutter and...

Page 10: ...may cause condensation or burns if touched When brazing the refrigerant piping only begin brazing after having carried out nitrogen substitution NOTE 1 or while inserting nitrogen into the refrigerant piping NOTE 2 Once this is done connect the indoor unit with a flared or a flanged connection NOTES 1 Refer to the Manual for Multi Installation for Buildings for directions on how to carry out nitro...

Page 11: ...r right left rear and left Refer to REFRIGERANT PIPING WORK for right rear and right direction and refer to Fig 20 for left rear and left direction For left drain pipe outlet remove the rubber plug and the insulation on the drain pipe connecting opening on the left side of the unit and change the position to the right side Pipe gauge Tightening torque Flare dimension A mm Flare shape φ 6 4 14 2 17...

Page 12: ...of drain hose inside the indoor unit Refer to Fig 24 If there is slack in the drain hose it may cause damage to the intake grill 2 Confirm that smooth drainage is achieved after the piping work Add 600 cc of water in the drain pan from the air outlet for confirming drainage Refer to Fig 25 CAUTION Drain piping connections Do not connect the drain piping directly to sewage pipes that smell of ammon...

Page 13: ...til all work is done 8 2 ELECTRICAL CHARACTERISTICS MCA Min Circuit Amps A MFA Max Fuse Amps A kW Fan Motor Rated Output kW FLA Full Load Amps A 8 3 SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE NOTES 1 Allowable length of transmission wiring between indoor outdoor units and between the indoor unit and the remote controller is as follows 1 Outdoor unit Indoor unit Max 1000 m Total wiring length...

Page 14: ... the connection may cause overheating When connecting wires of the same gauge con nect them according to the right hand figure Use the specified electric wire Connect the wire securely to the terminal Lock the wire down without applying excessive force to the terminal 2 Keep total current of crossover wiring between indoor units less than 12 A Branch the line outside the terminal board of the unit...

Page 15: ...board for remote controller 6P Power supply terminal board 2P or 3P Fastener Electric parts box Clamp 4 attached Clamp 4 attached Electric wiring diagram plate Ground wire After securing the cramp material to the bracket cut off any extra material Remote controller wire and connecting wire Fastener Wiring between units Electric parts box lid fixation screw 2 P Fig 26 Fig 27 L N Power supply wiring...

Page 16: ...P2 P1 P2 F1 F2 T1 T2 LN P1 P2 P1 P2 F1 F2 T1 T2 LN LN P1 P2 P1 P2 F1 F2 T1 T2 L N Outdoor unit No 1 System Indoor unit A Indoor unit B Indoor unit C Most downstream Indoor unit Power supply 220 240V 50Hz or 220V 60Hz Power supply 220 240V 50Hz or 220V 60Hz Power supply 220 240V 50Hz or 220V 60Hz Power supply 220 240V 50Hz or 220V 60Hz IN D OUT D F1 F2 F1 F2 Control box LN P1 P2 P1 P2 F1 F2 T1 T2 L...

Page 17: ...g instructions 10 3 Control by 2 Remote Controllers Controlling 1 indoor unit by 2 remote controllers When using 2 remote controllers one must be set to MAIN and the other to SUB MAIN SUB CHANGEOVER 1 Insert a wedge head screwdriver into the recess between the upper and lower part of remote controller and working from the 2 positions remove carefully the upper part The remote controller PC board i...

Page 18: ...fer to the manual of each optional controllers for centralized control 11 INSTALLATION OF THE SUCTION GRILLE AND THE AIR FILTER Install side panel and suction grille properly in the order opposite to detachment 12 TEST OPERATION Refer to the installation manual of the outdoor unit The operation lamp of the remote controller will flash when an error occurs Check the error code on the liq uid crysta...

Page 19: ... 0110 HT 3VA10807 4C EM01A143 cover fm Page 2 Friday September 14 2001 11 09 AM ...