Page 1-22
Check Every 24 Hours (Routine)
1-3-4
Cleaning the NG Chip Discharge Box (after Operation)
After the production, clean the NG chip discharge box.
1.
Turn OFF the power.
2.
Open the safety cover.
3.
Empty chips in the NG chip discharge
box.
∗
This picture shows the one for CM201/202-DS.
1-3-5
Cleaning the Used Tape Box (after Operation)
After the production, clean the used tape box.
∗
The used tape box is optional.
∗
Clean the used tape box during the production as well as after the operation.
CM201-DH, CM202-DH/DHU/DK, CM201-DS, CM202-DS
1. The cutting unit is set
1.
Open the cutting unit cover.
Tools
Required time
1 minute
NG chip discharge box
444C-522P
REL
EA
SE
TR
IP
O
F
F
ON
RE
S
E
T
Cutting unit cover
444C-E-MMA01-A03-06
4H4C-502P
To the next page
∗
While the cutting unit cover is open, the cutter
will not work for safety. After cleaning, be sure
to close it.
Tools
Scissors
Required time
3 minutes
E24C-401P
CM201-DH,
CM202-DH/DHU/DK
Cutting unit cover
CM201-DS, CM202-DS