22
g
“PHASE” and “CLOCK” factory preset setting values
Adjusting the speaker output. This can only be set when the monitor is equipped with an embedded audio unit BT-
YAE1700G (optional). If the monitor is not equipped with an embedded audio unit, the output will be in analog.
The underlined values are factory preset setting values.
The underlined values are factory preset setting values.
*1 The menu can be displayed when the lock is engaged.
The only menu setting that can be changed when the lock is engaged is the “CONTROL/LOCAL ENA” item.
When the lock is engaged, the picture adjusting knob is disabled.
Operations when the lock is engaged follow the settings in “LOCAL ENA”.
When the lock is engaged, the volume knob can be operated (
J
page 7,
).
When the lock is engaged, the key mark is displayed on the screen.
*2 This is only enabled when “CONTROL” is set to “REMOTE”.
FORMAT
CLOCK
PHASE
FORMAT
CLOCK
PHASE
640x400(70Hz)
800
18
1024x768(60Hz)
1344
2
640x480(60Hz)
800
17
1024x768(70Hz) 1328
22
640x480(75Hz)
840
10
1024x768(75Hz)
1312
16
640x480(85Hz) 832
5
1024x768(85Hz)
1376
17
800x600(60Hz)
1056
31
1280x768(60Hz)
1728
8
800x600(75Hz)
1056
12
1280x768(75Hz) 1712
31
800x600(85Hz) 1048
29
1280x1024(60Hz)
1688
20
AUDIO
Sub menu
Settings
Explanation
INPUT
SELECT
<AUTO>
<ANALOG>
<EMBEDDED>
Used to select speaker output.
<AUTO> When SDI input line is selected (front panel) :
embedded audio (SDI terminal)
When any other line than SDI input line is selected (front panel) :
analog (AUDIO input terminal)
<ANALOG>
Analog (AUDIO input terminal)
<EMBEDDED> When SDI input line is selected (front panel) :
embedded audio (SDI terminal)
When any other line than SDI input line is selected (front panel) :
No sound
EMBEDDED
SELECT L
<CH1–CH8>
(Factory preset
settings: CH1)
Used to select the audio channel of the embedded audio outputted to the left
speaker.
EMBEDDED
SELECT R
<CH1–CH8>
(Factory preset
settings: CH2)
Used to select the audio channel of the embedded audio outputted to the
right speaker.
CONTROL
Sub menu
Settings
Explanation
CONTROL
<LOCAL>
<REMOTE>
Used to select the operation. (Combined control lock)
<LOCAL>
Front operation enabled
<REMOTE>
Remote operation enabled (The front controls become locked)
*1
LOCAL
ENA
*2
<DIS.>
<INPUT>
When “REMOTE” is selected in “CONTROL”, this selects whether front
controls are enabled/disenabled.
<DIS.>
All front operations are disabled.
<INPUT>
All controls except for the [INPUT SELECT] button and
volume knob are disabled.
MARKER
Key mark
Main Menu
(continued)