Setting control when an event is detected
Sets up the details of commands to be executed when events are detected by the various detections (Motion
Detection, Alarm Detection, Sensor Detection, Sound Detection, and Shock Detection).
Control when event is detected Page
Setting
Description
External output of camera
Set a command to execute at the external equipment that is connected to
the camera for detection. ([Short] (default), [Open])
By placing a check mark and setting the time in [Output time], a reverse
setting of the command set in [Output value] (release of external output) is
performed. (
®
Optional Command
Select optional commands to execute for detection. Default is Beep 1000
1000.
When file paths or file names contain black spaces, place " " around them.
Parameters are placed outside of " ".
Example: "C:\Program Files\Beep.exe" 1000 1000
Command execution timing
You can set the timing of command execution by placing a check mark here.
([Execute once only at the time of recording start] (default), [Execute every
definite interval of time from recording start to end]) (
®
Operating Instructions
45
2.2 Setting Cameras
Summary of Contents for BB-HNP17A