43
Specifications
[GENERAL]
Power supply: DC 10.8 V to DC 16 V
Power consumption: 16.8 W
Ambient operating temperature
14°F to 113°F (–10°C to +45°C)
Storage temperature
–4°F to +140°F (–20°C to +60°C)
Ambient operating humidity
30% to 90% (no condensation)
Weight
Main unit
: 12.32 lb (5.6 kg)
Control panel : 7.48 lb (3.4 kg)
Dimensions (W
a
H
a
D)
Main unit
: 16
9
/
16
˝
a
8
11
/
16
˝
a
5
15
/
16
˝
(420
a
220
a
150 mm)
Control panel : 16
9
/
16
˝
a
2
1
/
16
˝
a
8
11
/
16
˝
(420
a
52
a
220 mm)
Pan-tilt heads supported
AW-PH300, AW-PH300A, AW-PH350, AW-PH500,
AW-PH600
Cameras supported
AW-E300, AW-E300A, AW-E600, AW-E800, AW-E800A
[CONTROL PANEL]
$
Input connectors
DC 12V IN socket
XLR, 4 pins
SERVICE connector
For maintenance purposes
$
Output connectors
CONTROL OUT TO MAIN UNIT connector
RJ45
Connecting cable:
10BaseT straight cables (UTP category 5),
max. 3,280 feet (1,000 meters)
$
Other
TERMINATION switch
Termination setting for communication line with main
unit
ID switch [1/2/3]
Control panel ID setting
[MAIN UNIT]
$
Input connectors
DC 12V IN socket
XLR, 4 pins
CONTROL IN TO CONTROL PANEL [1, 2, 3] connectors
RJ45
a
3
Connecting cable:
10BaseT straight cables (UTP category 5),
max. 3,280 feet (1,000 meters)
When more than one control panel is to be
connected to the main unit, make sure that the total
length of all the cables does not exceed 3,280 feet
(1,000 meters).
INCOM
Mini DIN, 6 pins
TALLY
Connector board
G/L IN
BNC
a
2, 75
Ω
automatic termination, loop-through
output
AUX IN
BNC, 75
Ω
termination
EXT/SERVICE connector
For maintenance purposes
REMOTE
RS-232C
$
Output connectors
CONTROL PANEL POWER OUT socket
XLR, 4 pins, dedicated control panel power output
Connecting cable:
Cable supplied
EXTERNAL CONTROL OUT
RJ45, connector for additional functions
CONTROL OUT TO PAN/TILT HEAD connectors
RJ45
a
5, control signal output for pan-tilt heads
Connecting cable:
10BaseT straight cables (UTP category 5),
max. 3,280 feet (1,000 meters)
PREVIEW MONITOR OUT connectors [1, 2, 3]
BNC
a
3, 75
Ω
output
Connecting cable:
BELDEN 8281, max. 32.8 feet (10 meters)
$
Other
TERMINATION switch
Termination setting for communication line with
control panel
indicates safety information.
Summary of Contents for AWRP605P - MULTI FUNCTION CONTROLLER
Page 45: ......