Installation Instructions provided

Operating Instructions

<Basics>

4K Integrated Camera

 

Model No. 

AW‑UN70WPC

 

Model No. 

AW‑UN70KPC

 

Model No. 

AW‑UN70WE

 

Model No. 

AW‑UN70KE

Operating  Instructions

Installation  Instructions

ENGLISH

DVQX1544ZA

CX1217TY0 -FJ

Printed in China

Before operating this product, please read the instructions carefully and save this manual for future use.

ENGLISH

<Basics>

Before using this product, be sure to read “Read this first!” (pages 5, 27 to 31).

This manual contains information excerpted from the Operating Instructions and the Installation Instructions.

For more information, please visit the Panasonic website 

(http://pro-av.panasonic.net/manual/en/index.html)

, and 

refer to the Operating Instruction (PDF).

FRANÇAIS

Avant d’utiliser cet appareil, assurez-vous de lire la section « Lire ces informations en premier ! ».

Pour de plus amples informations, visiter le site Web de Panasonic 

(http://pro-av.panasonic.net/manual/en/index.

html)

 et consulter le mode d’emploi (PDF).

ESPAÑOL

Antes de usar este producto, asegúrese de leer “Lea este documento en primer lugar!”.

Si desea obtener más información, visite el sitio web de Panasonic 

(http://pro-av.panasonic.net/manual/en/index.

html)

 y consulte las instrucciones de funcionamiento (PDF).

DEUTSCH

Bitte lesen Sie sorgfältig die „Bitte lesen Sie zuerst diesen Hinweis!“ vor der Nutzung dieses Produkts.

Weitere Informationen finden Sie auf der Panasonic-Webseite 

(http://pro-av.panasonic.net/manual/en/index.html)

 

und in der Bedienungsanleitung (PDF).

ITALIANO

Prima di utilizzare il prodotto, assicurarsi di leggere “Leggere prima quanto segue!”.

Per maggiori informazioni, per favore visitare il sito web Panasonic 

(http://pro-av.panasonic.net/manual/en/index.

html)

, e fare riferimento alle istruzioni per l’uso (PDF).

PУССКИЙ

Перед использованием данного прибора ознакомьтесь с информацией в разделе «Прочитайте 

нижеследующее до начала эксплуатации!».

Для получения дополнительной информации посетите веб-сайт Panasonic 

(http://pro-av.panasonic.net/

manual/en/index.html)

, а также обратитесь кинструкции по эксплуатации (PDF).

Summary of Contents for AW-UN70WPC

Page 1: ...manual en index html et consulter le mode d emploi PDF ESPAÑOL Antes de usar este producto asegúrese de leer Lea este documento en primer lugar Si desea obtener más información visite el sitio web de Panasonic http pro av panasonic net manual en index html y consulte las instrucciones de funcionamiento PDF DEUTSCH Bitte lesen Sie sorgfältig die Bitte lesen Sie zuerst diesen Hinweis vor der Nutzung...

Page 2: ...gyar A termékkel kapcsolatos biztonsági információkért és fontos értesítésekért látogasson el az alábbi weboldalra Latviešu Lai iegūtu informāciju par drošību un skatītu svarīgus paziņojumus par šo produktu apmeklējiet tālāk norādīto tīmekļa vietni Lietuvių Jei reikia saugos informacijos ir svarbių pranešimų apie gaminį apsilankykite toliau nurodytoje svetainėje Polski Informacje o bezpieczeństwie...

Page 3: ... LGPL V2 1 The software categorized as 3 5 are distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE For details refer to the license conditions that appear when the operation described on P 110 of the Operations and Settings is performed At least three 3 years from delivery of this product P...

Page 4: ...ng the unit on a desktop 17 When mounting the unit on a tripod 17 Connections 18 Connecting an NDI HX compatible switcher 18 Connecting a controller AW RP50 AW RP120 IP connection example 19 System example 1 connection with commercially available controller RS 232C daisy chain connection 20 System example 2 connection with commercially available controller RS 422 connection 21 System example 3 ser...

Page 5: ...s camera intended for use only with the Mount Bracket enclosed with the unit and Panasonic Direct Ceiling Mount Bracket WV Q105A Use with other apparatus is capable of resulting in instability causing possible injury WARNING Installation should only be performed by qualified installation personnel Improper installation may result in the entire apparatus falling down and causing injury Read this fi...

Page 6: ...ews No of screws Minimum withdrawal strength per screw Approx 1 5 kg 3 30 lb Direct mount supplied accessory Approx 0 23 kg 0 51 lb Hanging Desktop M4 screws supplied accessory 4 196 N 20 kgf Ensure that the mounting strength can support a weight that is at least five times the total mass of the equipment including the camera s main unit WV Q105A optional accessory Approx 0 15 kg 0 33 lb For ceili...

Page 7: ...can be plugged into and unplugged from the outlet easily When connecting the AC adaptor to a power outlet on the ceiling or on any other surface where dust may collect wipe off the dust on the power plug at periodic intervals as an anti tracking measure Power switch The unit does not have a power switch The power turns on when its power plug is connected to a power outlet When the power is turned ...

Page 8: ...pace Refer to the illustration and determine where the unit is to be installed and in which direction it should be mounted Factor in the unit mounting area and include space for the wires extending from its rear panel The asterisk in the illustration marks the position and dimensions of the hole for mounting the mount bracket 66 2 19 32 130 5 1 8 83 5 3 9 32 156 6 1 8 160 6 5 16 78 3 1 16 65 2 9 1...

Page 9: ...ls etc Note 3 Attach the drop prevention wire Pull out the drop prevention wire from the bottom panel of the unit and engage the end with the wire ring through the hole of the mount bracket hook Pull the drop prevention wire and check that it has been attached securely to the hook Pull out the drop prevention wire and engage it with the mount bracket hook End of hook Drop prevention wire Holding s...

Page 10: ... 8 kgf cm Main unit mounting screw M3 screw with flat washer spring washer Status display lamp Approx 15 On the camera main unit Holes 3 used to insert the bottom panel On the mount bracket Protrusions 3 used for inserting the camera Hole for checking the positioning Do not do this work while holding the camera head since doing so may result in malfunctioning of the unit Use only the screws suppli...

Page 11: ...ly secure the cable clamp B Fasten the cable clamp Loosely secure the cable clamp in the area shown above Take hold of the strap part slide the cable clamp until it stops moving and then secure it tightly Always disconnect the power supply before connecting or disconnecting cables Connecting or disconnecting cables while the power is turned on may result in malfunctions Note The unit is in the sta...

Page 12: ...prevention wire supplied with the WV Q105A to the anchor bolts Mounting the anchor bolts and direct ceiling mount bracket This job is facilitated if the direct ceiling mount bracket is loosely secured to the ceiling panel in one place and the direct ceiling mount bracket and anchor bolts are vertically aligned before the nuts are tightened up 2 First remove the screws which were loosely fastened i...

Page 13: ... approx 2 0 kg 4 41 lb of the camera once it has been installed but also the weight of the L shaped mounting fixture and its supports Use supports that are strong enough to withstand the total weight of the camera once it has been installed and any vibration or other forces to secure the L shaped mounting fixture If the supports are not capable of bearing this weight and forces the unit may become...

Page 14: ...used to secure the unit and mount bracket 4 Push the unit A Turn it approximately 15 degrees away from the installed position B and remove it C Main unit mounting screw M3 screw with flat washer spring washer Approx 15 Do not do this work while holding the camera head since doing so may result in malfunctioning of the unit Note 5 Disengage the drop prevention wire from the mount bracket ...

Page 15: ...he drop prevention wire 4 Mount the unit Align the position of the hole for checking the positioning with the status display lamp Align the holes on the camera main unit used to insert the bottom panel with the protrusions on the mount bracket used for inserting the camera push the camera to the bracket firmly and rotate the main unit by about 15 degrees in the direction of the arrow Secure the un...

Page 16: ...ial cable for G L IN Always disconnect the power supply before connecting or disconnecting cables Connecting or disconnecting cables while the power is turned on may result in malfunctions Note The unit is in the standby condition when the AC adaptor is connected The primary circuit is always live as long as the AC adaptor is connected to an electrical outlet Note for connecting with an HDMI cable...

Page 17: ...ect Incorrect When mounting the unit on a tripod Attach the tripod to the threaded holes for mounting the camera on the camera s bottom panel Place the tripod on a completely flat and level surface Tighten the screws by hand to mount the tripod securely Use screw for mounting the tripod that satisfy the following standard Screw for mounting tripod 1 4 20UNC ISO1222 6 35 mm 4 5 mm to 6 mm 0 18 to 0...

Page 18: ...ble switcher Supplied AC adaptor AW UN70 AW UN70 LAN cable Switching hub NDI HX compatible switcher Monitor Monitor External DC power supply The AC adaptor provided with the unit is not shown in the above figure Remote Camera Controller AW RP120 ...

Page 19: ...D 5 4 3 2 1 SV POWER ON BOOT NM 12V IN LAN Pan tilt head camera control signal HDMI SDI signal AW UN70 Remote Camera Controller AW RP50 Remote Camera Controller AW RP120 Supplied AC adaptor External DC power supply Supplied AC adaptor LAN cable Monitor The unit automatically detects the straight cable or crossover cable connected to the LAN connector ...

Page 20: ...details on the service switches see Service switch settings page 42 SW1 Camera address setting standard serial communication Set to AUTO or 1 to 7 Set address numbers so that they do not duplicate each other SW2 SW3 SW4 Communication format Enable standard serial communication ON SW7 Communication baud rate Set to 9600 bps OFF or 38400 bps ON based on your commercially available controller SW8 Com...

Page 21: ...ss setting standard serial communication Set to AUTO or 1 to 7 Set address numbers so that they do not duplicate each other SW2 SW3 SW4 Communication format Enable standard serial communication ON SW7 Communication baud rate Set to 9600 bps OFF or 38400 bps ON based on your commercially available controller SW8 Communication connector Set to RS 422 OFF Configure the following items in the camera m...

Page 22: ...t head camera control signal LAN cable straight cable System tally External DC power supply Remote Camera Controller AW RP120 Compact Live Switcher AW HS50 Supplied AC adaptor RS 422 connector The AC adaptor provided with the unit is not shown in the above figure Supplied AC adaptor Make sure the LAN cable connected to the RS 422 connector is a straight cable ...

Page 23: ...r AW HS50 Monitor 1 Monitor 2 Monitor Monitor LAN cable straight cable Remote Camera Controller AW RP50 The AC adaptor provided with the unit is not shown in the above figure Supplied AC adaptor Supplied AC adaptor Personal computer IP video display Wireless access point Mobile terminal IP video display The unit automatically detects the straight cable or crossover cable connected to the LAN conne...

Page 24: ...y available controller AW UN70 Monitor Supplied AC adaptor Remote camera control signal Infrared remote control supplied with commercially available controller Configure the service switches at the bottom of the unit For details on the service switches see Service switch settings page 42 SW6 Infrared output Set to ON System example 6 IP image transmission PoE AW UN70 IP decoder commercially availa...

Page 25: ...e USB 2 0 specification Connect a mini B connector to the unit The priority mode of the unit needs to be set to USB or USB 4K For details refer to Priority mode tab Priority mode page 67 in Operations and Settings Use communication software optional accessory that is compatible with the USB Video Class and USB Audio Class Note on grounding Ground the unit via the SIGNAL GND ground connector to gro...

Page 26: ...26 Appearance Unit mm inch 99 3 29 32 77 3 1 32 80 3 5 32 166 6 17 32 183 7 13 64 179 7 3 64 129 5 5 64 48 1 57 64 3 1 8 160 6 5 16 R80 R3 5 32 66 2 19 32 62 2 7 16 ...

Page 27: ...uipment CAUTION To reduce the risk of fire or electric shock and annoying interference use the recommended accessories only CAUTION In order to maintain adequate ventilation do not install or place this unit in a bookcase built in cabinet or any other confined space To prevent risk of electric shock or fire hazard due to overheating ensure that curtains and any other materials do not obstruct the ...

Page 28: ... 5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has ...

Page 29: ...er supply cord shall remain readily operable The AC receptacle mains socket outlet shall be installed near the equipment and shall be easily accessible To completely disconnect this equipment from the AC mains disconnect the power cord plug from the AC receptacle CAUTION Check the installation at least once a year An improper installation could cause the unit to fall off resulting in personal inju...

Page 30: ...ns If your apparatus is supplied with ferrite core s they must be attached on cable s following instructions in this manual 2 Performance level The performance level of the apparatus is equivalent to or better than the performance level required by these standards However the apparatus may be adversely affected by interference if it is being used in an EMC environment such as an area where strong ...

Page 31: ...ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse If the plug contains a removable fuse cover you must ensure that it is refitted when the fuse is replaced If you lose the fuse cover the plug must not be used until a replacement cover is obtained A replacement fuse cover can be purchased from your local dealer Before use Remove the connector cover How to replace...

Page 32: ... variations white or black to suit your intended application and environment Equipped with a newly developed codec engine the unit can output Full HD images at up to 60 fps via a network With 4K image quality it can also provide output at up to 30 fps Changing the Priority Mode enables operation for various applications Required personal computer environment CPU When using 1080 60p 59 94Hz and 108...

Page 33: ...rding or edited content and does not guarantee any content if recording or editing does not work properly Likewise the above also applies in a case where any type of repair is made to this unit Network security As you will use the unit connected to a network your attention is called to the following security risks A Leakage or theft of information through the unit B Use of the unit for illegal ope...

Page 34: ...by exposing the subjects to infrared rays Black and white images are output in this case The iris will be fixed at open IP video output function featured The unit is equipped with image compression and IP transmission LSI capabilities IP video transmission in SD format is possible In addition output at up to 30 fps is possible for 4K images and up to 60 fps for Full HD images Employing the functio...

Page 35: ...f the AC adaptor and a PoE power supply are connected simultaneously the AC adaptor will have priority Use a category 5e cable or higher when using a PoE power supply The maximum length of the cable between the power supply unit and the unit is 100 meters 328 ft Using a cable that is lower than category 5e may result in reduced power supply capabilities Notes 1 Power over Ethernet Plus Referred to...

Page 36: ...Mount bracket for installation surface Hanging Desktop 1 page 9 page 15 Main unit mounting screw with flat washer spring washer M3 6 mm 1 page 10 page 15 Drop prevention wire 1 already attached to the unit page 9 page 15 Bracket mounting screws bind head M4 10 mm 4 page 9 page 15 AC adaptor 1 Power cable 1 5 m 4 92 ft for AW UN70WPC AW UN70KPC 1 for AW UN70WE AW UN70KE 3 For U K and Saudi Arabia F...

Page 37: ... on and manual operations will no longer be possible for some of the items When using the ATW auto tracking white adjustment function under fluorescent lights the white balance may vary In some situations it may be hard to focus at the auto setting In cases like this select the manual setting and focus manually The appropriate brightness may not be obtained when shooting bright objects using the a...

Page 38: ...em parts The optical system parts are the very heart of the camera Under no circumstances must they be touched In the unlikely event that they have become dusty remove the dust by using a camera blower or by wiping them gently with a lens cleaning paper Do not point the camera directly at the sun or a laser beam no matter whether it is turned on or not Taking images of the sun laser beams or other...

Page 39: ...the light sensing directions in which the wireless remote control signals travel Note If the unit is installed near fluorescent lights plasma monitors or other such products or if the unit is exposed to sunlight the effects of the light may make it impossible for the unit to be operated using the wireless remote control Be sure to follow the steps below for installation and use Take steps to ensur...

Page 40: ...r side eStatus display lamp This lights in the following way depending on the status of the unit Orange When the standby status is established Green When the power is on Red When trouble has occurred in the unit Green and blinks twice When a signal matched by the remote control ID has been received from the wireless remote control optional accessory while the power is on Orange and blinks twice Wh...

Page 41: ...t nCable clamp This is used to hold the cable connection to the DC IN connector and prevent it from becoming disconnected oGround connector Connects to the ground connector on a wall outlet ground bar etc for grounding page 25 pRS 422 connector RS 422 This RS 422 connector RJ 45 is connected when exercising serial control over the unit from an external device Use a cable with the following specifi...

Page 42: ...0 bps 38400 bps OFF SW8 Communication connector RS 422 RS 232C OFF Perform switch settings before turning the unit on Cameras whose camera address setting switches are set to AUTO cannot coexist with cameras whose switches are set to 1 to 7 Manually setting multiple cameras to the same address will not allow you to control multiple cameras from a single controller simultaneously Notes Service swit...

Page 43: ...operated Once a button has been selected the unit corresponding to the selected button can be operated eSET button If this button is pressed when one of the Manual1 to 3 settings has been selected for Scene on the camera menu and the AWB A memory or AWB B memory has been selected by the white balance adjustment the white balance is automatically adjusted and registered in the selected memory fMODE...

Page 44: ... change will be restored kFOCUS buttons F N These are used to adjust the lens focus manually when the manual setting is established for the lens focus The focus is adjusted in the far using the F button and in the near using the N button lA FOCUS button This is used when automatically adjusting the lens focus mM FOCUS button This is used when manually adjusting the lens focus The FOCUS buttons F a...

Page 45: ...e units using wireless remote controls set a different remote control ID for each control When using one unit set the remote control ID to CAM1 unless the setting needs to be changed Setting procedure Operate the unit s camera menu or the web screen to select a remote control ID CAM1 to CAM4 The camera s CAM1 to CAM4 settings correspond to the CAM1 to CAM4 buttons on the wireless remote control Th...

Page 46: ...camera Similarly do not perform the Auto IP setting operation of the remote camera controller AW RP50 or AW RP120 at the same time The IP address settings may no longer be recognized as a result When you start the Easy IP Setup Software you may be asked for the administrator account password To enhance security the Easy IP Setup Software is designed so that when around 20 or more minutes have pass...

Page 47: ...hen you display the Live screen Live on the personal computer for the first time the installation screen for the plug in viewer software ActiveX appears Follow the instructions on the screen to perform installation Depending on the operating environment of your computer you may need to start Internet Explorer with an administrator account during installation Startup with an administrator account w...

Page 48: ...click Set button D Delete the default user name Click the Delete button after selecting the user name to be deleted admin 1 Depending on the model used the screens shown in the explanations may differ to the actual camera screens User name and password management Use a combination of characters and numbers that is difficult to guess Avoid using a string of the same characters such as 11111 birth d...

Page 49: ...has occurred Check the event log Operations and Settings P 109 Cannot operate common to wireless remote control controller Is the power on If the unit s status display lamp is off or if it has lit up orange it means that the unit s power is not being supplied Operations and Settings P 7 Have the limiter functions been set Operations and Settings P 125 to 126 Has the correct unit to be operated bee...

Page 50: ... and Settings P 91 Are all the cameras in the daisy chain connection turned on P 20 It may be necessary to upgrade the version of the controller so that the controller will support the unit P 36 The unit turns in the opposite direction to the one operated Has the stand alone Desktop installation setting been selected correctly Operations and Settings P 48 P 87 The reversal setting may have been es...

Page 51: ...version of the controller so that the controller will support the unit INPUT Power DC 12 V IN PoE IEEE802 3at compliant Mic line input Stereo mini jack ø3 5 mm Input impedance Approx 2 kΩ unbalanced Mic input Supported microphones Stereo mic plug in power on off switching via menu Supplied voltage 2 5 V 0 5 V Mic input level 60 dBV 3 dBV 0 dB 1 V Pa 1 kHz Line input Input level 10 dBV 3 dBV G L IN...

Page 52: ...B 12 dB 18 dB 24 dB During Auto 0 dB 6 dB 12 dB and 18 dB are available for Auto F Mix Max Gain setting ND filter Auto Through 1 4 1 16 1 64 Auto can be selected when Scene is set to Full Auto Electronic shutter speed During Full Auto 59 94 Hz 1 60 to 1 2000 Auto Slow Shutter Off 1 30 to 1 2000 Auto Slow Shutter On 50 Hz 1 50 to 1 2000 Auto Slow Shutter Off 1 25 to 1 2000 Auto Slow Shutter On Duri...

Page 53: ...and alone Desktop or suspended Hanging To ensure safety the unit must be secured using the mount bracket supplied Camera pan tilt head control IP connecting cable When connecting through a hub LAN cable 2 category 5 or above max 100 m 328 ft When using a PoE hub LAN cable 2 category 5e or above max 100 m 328 ft When a hub is not used LAN cable 2 category 5 or above max 100 m 328 ft AW protocol con...

Page 54: ...80 720 640 360 320 180 1 The frame rate may be lower than the setting depending on the operating conditions 2 When the image resolution is 3840 2160 640 360 or 320 180 60fps or 50fps cannot be selected for the frame rate Supported protocol IPv4 TCP IP UDP IP HTTP HTTPS RTSP RTP RTP RTCP FTP DHCP DNS NTP IGMP UPnP ICMP ARP RTSPoverTCP RTSPoverHTTP SSL TLS MultiCast UniCast IPv6 TCP IP UDP IP HTTP H...

Page 55: ...ftware 46 Electronic shutter speed 52 F Frame mix 52 G Gain selection 52 Gamma 52 H HDMI cable 11 16 I Image stabilization 52 IP address 46 IP decoder 24 L LAN cable 11 16 18 23 24 41 M MAC address 46 Main unit mounting screw 10 14 15 36 Microphone 25 Mount bracket 8 9 12 15 36 40 N ND filter 52 NDI HX compatible switcher 18 O Output format 52 P PoE 35 PoE compatible switching hub 24 Power cable 3...

Page 56: ...take them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment For more information about collection and recycling please contact your local municipality Penalties may be applicable for incorrect disposal of this waste in acc...