User management screen [User mng.]
The users and personal computers (IP addresses) that can access the
unit from personal computers and mobile terminals are registered in the
User management screen [User mng.].
The User management screen [User mng.] consists of [User auth.] and
[Host auth.].
User authentication screen [User auth.]
Click the [User auth.] of User management screen [User mng.].
Configure the user authentication settings for the personal computers
and mobile terminals that can access the unit.
Up to 9 users can be registered.
<NOTE>
• If user authentication fails more than 8 times within a 30-second period
from the same IP address (personal computer), access to the unit will
be disabled for a certain period.
z
Setting status
The current user authentication settings and user authentication method
are displayed. The currently registered account information is also
displayed.
z
Mode
User auth. [On, Off]
User authentication is set to [On] or [Off] here.
The setting is confirmed with the [Set] button.
Factory settings:
Off
Authentication [Basic, Digest]
Specify the method of user authentication to use.
The setting is confirmed with the [Set] button.
Basic
Use basic authentication.
Digest
Use digest authentication.
Factory settings:
Digest
Preset Zoom Mode [Mode A, Mode B]
Select the zoom operation for when preset memory is recalled.
Mode A
Perform the zoom operation in line with the pan/tilt
operation.
Mode B
Perform the zoom operation quicker than the pan/tilt
operation.
Factory settings:
Mode A
Freeze During Preset [Off, On]
Turn the function for freezing images during preset playback off/on.
When this is set to [On], preset playback is performed with a still of
the image immediately preceding the start of preset playback being
output. The image freeze is released when preset playback is finished.
Factory settings:
Off
Collaboration capability [Linkage]
P2 Cast connection setting screen [P2 Cast]
Sets whether to enable or disable connection to P2 Cast, as well as the
destination server URL and the user account.
The setting is confirmed with the [Set] button.
Mode [On, Off]
Sets whether to connect this unit to P2 Cast via a network.
Factory settings:
Off
Cloud URL
Sets the server URL of P2 Cast to be connected when [Mode] is [On].
<NOTE>
• You can set the URL with maximum 512 characters.
User ID
Sets the user ID for connection to P2 Cast when [Mode] is [On].
Password
Sets the password for connection to P2 Cast when [Mode] is [On].
108
Web screen configurations (continued)
Summary of Contents for AW-UE50WP
Page 153: ...153 MEMO ...