– 44 –
Chapter 4 Preparations — Various settings
[Down Converter] tab
Makes the settings for down-converters built into the <SDI OUT 14>/<SDI OUT 16> terminals.
2
Select the <IN OUT> button
→
[C/C OUT]
→
[SDI OUT 13] to [SDI OUT 16] tabs, and make the color corrector settings.
f
This function will be available in V2.00.00 or higher.
f
Make the settings for color correctors built into the <SDI OUT 13> to <SDI OUT 16> terminals.
f
Setting MultiView displays
If the output signal is set to MV1 to MV4, multiple images can be simultaneously displayed on a maximum of 16 split screens.
f
For details, refer to “Setting MultiView displays” (page 114).
1
Select the <MV> button
→
[MV1‑4]
→
[MV1] to [MV4] tabs.
2
In the [Pattern] column, make the settings for the split pattern of the MultiView display.
f
When [Assign] is selected, the source settings screen will be displayed on a sub-screen.
3
In the [MV Frame]/[Tally Box]/[Tally Label L]/[Tally Label R]/[Display] column, set the information displayed on the sub‑screen.
f
[Tally Label L]/[Tally Label R] will be available in V2.00.00 or higher.
Setting a tally
Setting reference outputs
For details on the tally group settings, refer to “Setting a tally” (page 136).
1
Select the <SYS> button
→
[PERIPHERAL]
→
[Tally] tab.
2
Select an item in [Target A], [
+
Target B], [
+
Target C], or [
+
Target D] in the [Tally Group1‑1] column.
f
Select up to 4 reference outputs to be used for the on-air tally.
3
Select an item in [Target A], [
+
Target B], [
+
Target C], or [
+
Target D] in the [Tally Group2‑1] to [Tally Group4‑1] columns.
f
Besides [Tally Group1-1], additional 3 tally groups can be set. When [Color] is selected, colors to be used for the tally in the MultiView display can
also be set.
Setting the parallel tally
1
Select the <SYS> button
→
[PERIPHERAL]
→
[GPI IN]/[GPI OUT] tab, and make the following settings.
[GPI IN] tab
Assigns Tally G1 DSBL through Tally G4 DSBL to externally control enabling/disabling of each tally group.
[GPI OUT] tab
Assigns source tally outputs by tally group.
Setting the state replicated when power is on
Set the status replicated when the power is turned on.
f
For details on the settings, refer to “Startup settings/initialization” (page 140).
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Boot] tab.
2
Make the following settings in the [Boot Select]/[Project Data] column.
[Boot Select] column
Selects the setting data to be used at the startup from resume data and project data.
[Project Data] column
Specifies project file to be used at the startup.
Setting date and time
Set the date and time to be used as a timestamp when saving files to the memory card or the Storage Module AV‑HS60D1 (optional). It can also be
displayed on the split screen of the MultiView display.
1
Select the <SYS> button
→
[MAINTENANCE]
→
[Misc] tab.
2
Set the date and time in the [Date]/[Time]/[LTC] columns.
[Date] column
Sets the year, month, and date in [Year], [Month], and [Date].
[Time] column
Sets the hour, minute, and second in [Hour], [Minute], and [Second].
[LTC] column
Displays the information input to the <LTC IN> terminal and reflects it in the [Time] column.
Summary of Contents for AV-HS6000
Page 5: ...Please read this chapter and check the accessories before use Chapter 1 Overview ...
Page 45: ...This chapter describes menu operations Chapter 5 Basic Operations ...
Page 144: ...This chapter describes the terminals and signals of the unit Chapter 9 External Interfaces ...
Page 157: ...This chapter describes the setting menu table and terms Chapter 11 Appendix ...