![Panasonic Attune WX-Z3040 Installation Instructions Manual Download Page 54](http://html.mh-extra.com/html/panasonic/attune-wx-z3040/attune-wx-z3040_installation-instructions-manual_258122054.webp)
9.3 External Device Control
The external equipment connected with the DEVICE CONT terminal of the Center Module can be controlled with C button
of All in One Headset or Order Taker Unit.
Center Module
CONNECTOR
2
ORDER INTERFACE
External operation
1
AUX MIC +
VDD: 5VDC
2
AUX MIC -
3
AUX MIC GND
R: 82 ohms or more
4
AUX MIC PTT
5
COM
To micro
computer
To control circuit
6
DEVICE CONTROL
Not active: 5V
Active: 0V
7
COM
8
N.C
PS2532L
V
CE
: 300V max
Ic: 150mA