– 20 –
Chapter 2 Description of Parts — Image Processing Unit AK-SHU800
Rear panel
RESERVE
ROP
AUX
TRUNK
COMMUNICATION
LAN
IN
OUT
75
Ω
AUTO
HD SDI OUT
HD SDI PROMPT
1
2
IN
IN
OUT
OUT
SDI OUT
OPT
AC IN
〜
SIGNAL GND
REF
1
2
3
4
AK-SHU800E
AK-SHU800PS
7
6
5
4
3
1
2
10
11
12
13
14
15
9
8
1 <HD SDI OUT 1> terminal
This is the main line output terminal dedicated for HD SDI.
<HD SDI OUT 2> terminal
This is the monitor output terminal dedicated for HD SDI.
@
@
NOTE
t
Use a cable that is 5C-FB or above.
2 <SDI OUT> terminal
This is the main line output terminal dedicated for 8K, 4K and HD CROP SDI
@
@
NOTE
t
Use a cable that is 5C-FB or above for 3G SDI.
t
Use a BNC cable for 12G for 12G SDI.
3 <OPT OUT> terminal
Connect to the <OPT IN> terminal on the camera using an optical fiber cable.
@
@
NOTE
t
There is a protective cap on the terminal. Remove it before use.
4 <OPT IN> terminal
Connect to the <OPT OUT> terminal on the camera using an optical fiber cable.
@
@
NOTE
t
There is a protective cap on the terminal. Remove it before use.
5 <HD SDI PROMIT IN> terminal
These connectors are for inputting HD SDI prompter signals.
Input images can be viewed through the <HD SDI PROMPT OUT> terminal on the camera.
<HD SDI PROMIT OUT> terminal
This is active through output from the <HD SDI PROMPT IN> terminal.
6 <REF IN> terminal
This is the reference signal input connector when applying external synchronization.
BB (black burst) signals or tri-level signals can be input, and are automatically recognized.
<REF OUT> terminal
This is the loop through output from the <REF IN> terminal.
@
@
NOTE
t
When a cable is not connected to the <REF OUT> terminal, it automatically becomes a 75 Ω terminal. The 75 Ω terminal is released when a cable is connected.
t
When a cable is connected to the <REF OUT> terminal, do not leave the connector at other end of the cable open.
7 Cooling fan
This is the unit's cooling fan.
t
Do not block fans or ventilation during operation. Heat can build up internally and this may cause a fire.
t
Expected life of these fans is approximately 40,000 hours. (When used at a room temperature of 25
°C
) Replace when they reach the expected life.
t
Be sure to contact your dealer for the replacements.
8 AC power socket
This socket is for inputting AC power.
Connect the supplied power cable, and use a 3-prong outlet and ground the unit properly.
9 <SIGNAL GND> terminal
Connect this to the system ground.
10 <RESERVE> terminal
Not used.
11 <ROP> terminal
This terminal is for connecting a ROP (sold separately).
12 <AUX> terminal
This connector is used for controlling tally output.
13 <TRUNK> terminal
It is possible to transmit and receive camera trunk data.
14 <COMMUNICATION> terminal
This connector is for connecting the tally signal with an external system.
15 <LAN> terminal
This connector is for connecting an ROP and PC for ROI control with an IP connection.
Use a switching hub and connect using a 1000BASE-T/100BASE-TX straight cable.
Summary of Contents for AK-SHB800G
Page 4: ...Before using the camera read this chapter Chapter 1 Overview ...
Page 21: ...This chapter describes the operation of this camera Chapter 3 Operation ...
Page 85: ...This chapter describes the specifications of this product Chapter 8 Specifications ...
Page 92: ...Web Site https www panasonic com Panasonic Corporation 2019 ...