Front panel 5
1 2
3 4
6
9
5
13
16
7
10
8
14
15
17
12
11
1
[ALM] indicator
This is the camera and CCU warning indicator lamp.
Consult your dealer if a failure occurs.
The indicator's color changes to indicate when the camera and CCU optical reception level is
not strong enough, when a data error has occurred in the CCU optical transmission/reception
section, and when a fan error or temperature error has been occurred on the camera or CCU.
2
[OPT] indicator
This is the camera cable warning indicator lamp.
Status displays
Lit orange:
Warns that an optical transmission error has occurred.
Lit red:
Indicates that the camera is not connected to the CCU.
Off:
The camera cable is connected normally.
3
[EXT] indicator
This indicator lights to warn that the lens extender is set to something other than 1x.
Status displays
On: The lens extender is set to something other than 1x.
Off: This indicates that the lens extender is not being used or that it is not available.
4
[D.EXT] indicator
This indicator lights to warn that the digital extender is set to something other than 1x.
Status displays
On: The digital extender is set to something other than 1x.
Off: This indicates that the digital extender is not being used or that it is not available.
5
Adjustment value display
Displays the ND filter, CC filter, iris, master gain, master pedestal, shutter, or sync shutter
adjustment value based on the item selected with the [DISP] button.
6
[ND] indicator
Lights when the ND filter is selected with the [DISP] button.
Status displays
Lit green:
Standard position set in the ROP menu.
Lit orange:
Updated from the standard position set in the ROP menu.
n
The standard position of the ND filter can be set in [ROP SETTING] > [STD POSITION
ND] in the ROP menu.
“STD POSITION ND” (see page 111)
7
[CC] indicator
Lights when the CC filter is selected with the [DISP] button.
Status displays
Lit green:
Standard position set in the ROP menu.
Lit orange:
Updated from the standard position set in the ROP menu.
n
The standard position of the CC filter can be set in [ROP SETTING] > [STD POSITION
CC] in the ROP menu.
“STD POSITION CC” (see page 111)
- 28 -
Parts and their functions