MECH-35
3-37. PB Head LISTA Sensitivity Adjustment and Sensitivity Detection
(50M Mode)
SPEC.
Sensitivity 100±10 (mV/
µ
m)
MODE
SERVO Adjustment Menu “A17 : PBL GAIN 25”
!
ATF (PB-L)
TP5701 RF (F8) (not TP6701 (R/P-L ATF))
"
H SW (PB-L)
TP232 SERVO (F7)
TEST POINT
#
GND
TG102
ADJUSTMENT
SERVO Adjustment Menu: “A16 : PBL GAIN 50”
TAPE
NTSC: VFM3581KM or VFM3581KL(LISTA)
(PAL: VFM3681KM or VFM3681KL(LISTA))
1. Open the Service Menu and select “A16: PBL GAIN 50” in the “SERVO ADJUST” menu. Set the Lista software
in 50M mode.
2. Playback a LISTA alignment tape (VFM3581KM or VFM3581KL).
3. Select the LISTA Main Menu “(6) ATF Error Signal Monitor” so that the screen of <ATF Error Signal monitor>
appears. Then press Enter to start the software.
4. When the picture is appeared as shown in figure 3-37-1, adjust ATF Gain (A16: PBL GAIN 50) so that the “Sens.
Value:” is in the Specification.
5. After finishing the Adjustment, press ESC key to return the main menu.
6. Select the Lista Main Menu “(1) Sensitivity Measurement” so that the screen of <ATF Error Signal monitor>
appears.
7. Playback a Lista alignment tape and press “ENTER” to start the Sensitivity measurement.
8. Confirm that the sensitivity value is within the specification. (refer to figure 3-37-2).
9. If it is out of specification, return to item 3.
Figure 3-37-1
Adjust within specification
Summary of Contents for AJSD955B - DVCPRO50 STUDIO DECK
Page 3: ...3...
Page 4: ...4 AJ YA931G AJ YA932G AJ YAC930G...
Page 6: ...6 AJ SD930P AJ SD955AP...
Page 7: ...7 AJ YA931G AJ YA932G AJ YAC930G...
Page 8: ...FCD0211NTIK83K84...
Page 65: ...INF 56 14 ERROR MESSAGES...
Page 66: ...INF 57...
Page 67: ...INF 58...
Page 72: ...INF 63 16 CIRCUIT BOARD LAYOUT DRAWING...
Page 105: ...MECH 26 Figure 3 32 3 Figure 3 32 4 Adjust within specification Confirm this value...
Page 109: ...MECH 30 Figure 3 34 3 Figure 3 34 4 Adjust within specification Confirm this value...
Page 111: ...MECH 32 Figure 3 35 2 Confirm this value...