MECH-28
Waving Measurement Procedures
1.
Press “SPACE” key to perform the Peak Hold in 30 seconds when linearity is displayed.
2.
After finishing the Peak Hold, press “SHIFT” and “ } ” key simultaneously on the Key Board, then the numerical
values of “Linearity” and “Waving” is displayed on left lower portion of screen. And confirm the numerical values
are in the specification. Also confirm the waving is same level from entrance side to exit side. If the “Linearity”
and “Waving” are out of specification and also it caused by insufficient limit of entrance or exit side of envelope,
adjust height of S1 and T1 post.
3.
After this measurement is finished, press the ESC key to return to the main menu.
Information : How to save the LISTA Data
Linearity waveform data, measurement value and waving value can be saved as one file data to PC.
1.
Basically this operation should be performed after linearity and waving measurement is finished.
2.
Select the item “<3> Data Save/Load” on the LISTA main menu, and select the item “<1> Save”.
3.
The linearity waveform as Peak Hold is displayed on the screen, and message “File Name?” appears on the
screen. Then enter the File Name less than 8 letters. Nextly enter the Serial No. and press enter, then message
“Comment?” appears on the screen, then enter the Comment less than 20 letters. As comment, enter the
Model Number, Head Rotation Hours etc to use them for management of each VTR’s linearity data.
4.
After completion of saving, select the item “<2> Load” of the item “<3> Data Save/Load”, then the saved File
Name appears on the screen. And select previously saved file to confirm the waveform and numerical value is
displayed correctly. By pressing “SHIFT” and “ } ” key simultaneously on the Key Board, the numerical values of
“Linearity” and “Waving” is displayed on left lower portion of screen.
Confirm this value
Summary of Contents for AJSD955B - DVCPRO50 STUDIO DECK
Page 3: ...3...
Page 4: ...4 AJ YA931G AJ YA932G AJ YAC930G...
Page 6: ...6 AJ SD930P AJ SD955AP...
Page 7: ...7 AJ YA931G AJ YA932G AJ YAC930G...
Page 8: ...FCD0211NTIK83K84...
Page 65: ...INF 56 14 ERROR MESSAGES...
Page 66: ...INF 57...
Page 67: ...INF 58...
Page 72: ...INF 63 16 CIRCUIT BOARD LAYOUT DRAWING...
Page 105: ...MECH 26 Figure 3 32 3 Figure 3 32 4 Adjust within specification Confirm this value...
Page 109: ...MECH 30 Figure 3 34 3 Figure 3 34 4 Adjust within specification Confirm this value...
Page 111: ...MECH 32 Figure 3 35 2 Confirm this value...