189
Menu: Menu Description Tables
Me
nu
The ____ in the Adjustable Range column indicates the preset mode.
MAIN OPERATION
BATTERY/P2CARD
Items/
Data Saved
Adjustable
Range
Remarks
BATTERY
SELECT
PROPAC14
TRIMPAC14
HYTRON50
HYTRON140
DIONIC90
DIONIC160
NP-L7
ENDURA7
ENDURA10
ENDURA-D
PAG L95
BP-L65/95
NiCd14
TYPE A
TYPE B
Select the battery to use. Remaining
capacity detection is also performed
according to the selected battery.
The variable range is changed by the
item settings selected on the [BATTERY
SETTING1] (page 190) and [BATTERY
SETTING2] (page 191) menus.
The initial value for “TYPE A” is set to
“DIONIC90” while the same for “TYPE B”
is set to “HYTRON140”.
When BP-GL65 or BP-GL95, a battery
made of Sony, is used, set this to “BP-
L65/95”.
– C U F –
EXT DC IN
SELECT
AC_ADPT
PROPAC14
TRIMPAC14
HYTRON50
HYTRON140
DIONIC90
DIONIC160
NP-L7
ENDURA7
ENDURA10
ENDURA-D
PAG L95
BP-L65/95
NiCd14
TYPE A
TYPE B
Set the remaining capacity detection
type when a battery is connected to the
DC IN connector. Remaining capacity
detection is also performed according to
the selected battery type.
The variable range is changed by the
item settings selected on the [BATTERY
SETTING1] (page 190) and [BATTERY
SETTING2] (page 191) menus.
Analog voltage is displayed on the
viewfinder screen.
When BP-GL65 or BP-GL95, a battery
made of Sony, is used, set this to “BP-
L65/95”.
– C U F –
BATT NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep when the battery level is low.
– C U F –
BATT NEAR
END CANCEL
ON
OFF
If set to “ON”, the warning tone and
indication can be canceled by pressing
the MODE CHECK button when BATT
NEAR END ALARM is triggered.
– C U F –
BATT END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep when the battery is empty.
– C U F –
BATT REMAIN
FULL
70%
100%
Set the display of the remaining battery
level indicator bar in the display window
when a battery with this function is used.
70%:
Indicate FULL at 70% capacity.
100%:
Indicate FULL at 100% capacity.
– C U F –
Items/
Data Saved
Adjustable
Range
Remarks
CARD NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep when the space remaining on the
P2 card is small.
– C U F –
CARD NEAR
END TIME
2min
3min
Set the time at which to indicate that
there is little space remaining on the P2
card.
– C U F –
CARD END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep when the P2 card is full.
– C U F –
CARD REMAIN/
3min/
5min/
Set the length of time for one segment
(
) of the P2 card’s remaining capacity
indicator bars.
3min/
:
One segment represents
3 minutes.
5min/
:
One segment represents
5 minutes.
– C U F –
AJ-HPX2700G-VQT1V27_eng.book 189 ページ 2008年9月2日 火曜日 午後5時43分