8
8-6-3
BATTERY SETTING2
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved
Adjustable
Range
Remarks
NiCd14
_
•
Enable selection under BATTERY SELECT.
_
:
Enable selection.
• :
Disable selection.
NEAR END 11.0
:
13.6
:
15.0
Set the NEAR END voltage in 0.1 V steps.
END
11.0
:
13.2
:
15.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
– C U F –
NiCd13
_
•
Enable selection under BATTERY SELECT.
_
:
Enable selection.
• :
Disable selection.
NEAR END 11.0
:
12.7
:
15.0
Set the NEAR END voltage in 0.1 V steps.
END
11.0
:
12.2
:
15.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
– C U F –
NiCd12
_
•
Enable selection under BATTERY SELECT.
_
:
Enable selection.
• :
Disable selection.
NEAR END 11.0
:
11.5
:
15.0
Set the NEAR END voltage in 0.1 V steps.
END
11.0
:
11.2
:
15.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
– C U F –
TYPE A
_
•
Enable selection under BATTERY SELECT.
_
:
Enable selection.
• :
Disable selection.
FULL
12.0
:
15.0
:
17.0
Set the voltage to display the FULL
indication in 0.1 V steps.
NEAR END 11.0
:
13.6
:
15.0
Set the NEAR END voltage in 0.1 V steps.
END
11.0
:
13.2
:
15.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
– C U F –
Items/
Data Saved
Adjustable
Range
Remarks
TYPE B
_
•
Enable selection under BATTERY SELECT.
_
:
Enable selection.
• :
Disable selection.
FULL
12.0
:
13.5
:
17.0
Set the voltage to display the FULL
indication in 0.1 V steps.
NEAR END 11.0
:
11.8
:
15.0
Set the NEAR END voltage in 0.1 V steps.
END
11.0
:
11.1
:
15.0
When MANUAL is selected in the menu
above, set the END voltage in 0.1 V steps.
– C U F –
Summary of Contents for AJ- SPX800E