113
8
Chapter 8 Menu Description Tables
(continued)
8-5-7 USER SW GAIN
8-5-8 IRIS
8-6 MAIN OPERATION
8-6-1 BATTERY/P2CARD
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Data Saved
Adjustable
Range
Remarks
S.GAIN
30 dB
_
•
Select whether or not to enable 30dB
for SUPER GAIN.
_
:
Enable.
•
:
Disable.
– C U F E
36 dB
_
•
Select whether or not to enable 36dB
for SUPER GAIN.
_
:
Enable.
•
:
Disable.
– C U F E
Items/
Data Saved
Adjustable
Range
Remarks
A.IRIS LEVEL
000
:
050
:
100
Set the target value for auto iris.
– C U F E
A.IRIS PEAK/
AVE
000
:
040
:
100
Determine the peak-to-standard ratio
for the auto iris.
A larger value sets the auto iris to
respond to the peak in the IRIS
detection window, while a smaller value
sets it to respond to the average value
in the window.
– C U F E
A.IRIS MODE
NORM1
NORM2
CENTR
Select the auto iris detection window.
NORM1:
The window closer to the center
of the screen.
NORM2:
The window closer to bottom of
the screen.
CENTR:
The spot window in the center of
the screen.
– C U F E
S.IRIS LEVEL
000
:
080
:
100
Set the target value for the super iris.
– C U F E
IRIS GAIN
CAM
LENS
Select which unit controls IRIS GAIN.
<Note>
Lenses with an extender, such as
C
2,
C
0.8 sold before FUJINON DIGI
POWER, perform IRIS compensation
while enabling the extender. Therefore,
if this setting is switched to CAM, the
camera’s iris control will not operate
properly.
– C U F E
IRIS GAIN
VALUE
01
:
08
:
20
Set the adjustable value for IRIS GAIN.
This setting is effective when CAM is
selected for IRIS GAIN.
– C U F E
Items/
Data Saved
Adjustable
Range
Remarks
BATTERY
SELECT
PRO14
TRIM14
HYTRON50
HYTRON100
HYTRON120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Select the battery to use. Remaining
capacity detection is also performed
according to the selected battery.
The selectable battery types change
depending on the settings under [8-6-2
BATTERY SETTING1] and [8-6-3
BATTERY SETTING2].
– C U F –
EXT DC IN
SELECT
AC_ADPT
PRO14
TRIM14
HYTRON50
HYTRON100
HYTRON120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Set the remaining capacity detection
type when a battery is connected to the
DC IN connector. Remaining capacity
detection is also performed according
to the selected battery type.
The selectable battery types change
depending on the settings under [8-6-2
BATTERY SETTING1] and [8-6-3
BATTERY SETTING2].
<Note>
The % display is disabled even when a
digital battery is connected to the DC IN
connector.
– C U F –
BATT NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm
to beep for BATT NEAR END ALARM.
– C U F –
BATT NEAR
END CANCEL
ON
OFF
If set to ON, the warning tone and
indication can be canceled by pressing
the MODE CHECK button when BATT
NEAR END ALARM is triggered.
– C U F –
BATT END
ALARM
ON
OFF
Select whether or not to set the alarm
to beep for BATT END ALARM.
– C U F –
BATT REMAIN
FULL
70%
100%
Set the display content of the remaining
battery capacity indicator bars in the
display window when using a digital
battery.
70%:
Indicate FULL at 70% capacity.
100%:
Indicate FULL at 100% capacity.
– C U F –