Item
Description of settings
[BACKLIGHT]
Adjusts the brightness of the LCD monitor backlight.
[
−
3]:
Becomes the darkest.
[
−
2], [
−
1]:
Darkens more than normal.
[0]:
Normal brightness.
[1]:
Brightens more than normal.
f
Factory setting: [0]
[BRIGHTNESS]
Adjusts the brightness of the LCD monitor.
[
−
15]…[15]
f
Factory setting: [0]
[COLOR LEVEL]
Adjusts the LCD monitor hue.
[
−
15]…[15]
f
Factory setting: [0]
[CONTRAST]
Adjusts the contrast of the LCD monitor.
[
−
30]…[30]
f
Factory setting: [0]
[SELF SHOOT]
Selects whether to invert the right and left sides of the LCD monitor.
[NORMAL]:
Does not invert the left and right sides.
[MIRROR]:
Inverts the left and right sides.
f
Factory setting: [MIRROR]
[VF/LCD CHAR]
Selects whether to display a character on the image of the LCD monitor and viewfinder.
[ON]:
Displays characters on both the viewfinder and LCD monitor.
[VF-OFF]:
Does not superimpose on the viewfinder, and displays on the LCD monitor.
[LCD-OFF]:
Does not superimpose on the LCD monitor, and displays on the viewfinder.
f
Factory setting: [ON]
This item can be set in the main menu
→
[VF]
→
[VF DISPLAY] as well.
[BATTERY/P2CARD]
Item
Description of settings
[BATTERY SELECT]
Selects the battery to use.
[HYTRON140], [DIONIC90], [ENDURA10], [PAG L96e]:
Detects the battery charge level according to the
selected battery when Anton/Bauer HYTRON140 or DIONIC90, IDX ENDURA10 (E-10), and PAG PAG
L96e are selected.
[TYPE A], [TYPE B], [TYPE C]:
Select either item when a battery other than [HYTRON140], [DIONIC90],
[ENDURA10], and [PAG L96e] is used. At this time, set [FULL] (full voltage), [NEAR END] (near end
warning voltage), and [END] (end voltage) in the main menu
→
[I/F SETUP]
→
(page 191) according to the battery in use.
[BATT STAT]:
By selecting [BATT STAT] when using a battery whose charge level is detected as a
percentage value, near end and end operations are conducted according to the percentage value of the
charge level. Set the percentage value of [BATT STAT NEAR END] (near end) and [BATT STAT END]
(end) in the main menu
→
[I/F SETUP]
→
[BATTERY SETTING] (page 191) according to the battery in
use.
[ENDURA STAT]:
Select it when ENDURA battery by IDX is used to perform near end and end operations
according to the percentage value of the charge level information. Set the percentage value of [ENDURA
STAT NEAR END] (near end) and [ENDURA STAT END] (end) in the main menu
→
[I/F SETUP]
→
[BATTERY SETTING] (page 191) according to the battery in use.
f
Factory setting: [DIONIC90]
When the battery charge level percentage cannot be detected, it will follow the setting value of [TYPE A]
even if it is set to [BATT STAT] or [ENDURA STAT]. Make sure that the [TYPE A] setting values [FULL]
(fully charged), [NEAR END] (near end), or [END] (end) is appropriate for the battery being used.
[EXT DC IN SELECT]
Sets the type of charge level to connect a battery to the <DC IN> terminal. Also detects a charge level that
corresponds to the selected type.
Information about selecting a battery type is the same as [BATTERY SELECT].
Displays the analog voltage on the viewfinder screen.
[DC PWR SUPPLY], [HYTRON140], [DIONIC90], [ENDURA10], [PAG L96e], [TYPE A], [TYPE B],
[TYPE C]
f
Factory setting: [DC PWR SUPPLY]
[BATT NEAR END ALARM]
Selects whether to play the warning sound at battery near end.
[ON], [OFF]
f
Factory setting: [OFF]
[BATT NEAR END CANCEL]
If set to [ON], the warning sound and warning display output can be canceled when the <MARKER
SEL>/<MODE CHECK/MENU CANCEL> switch is pushed towards the <MCK/MCL> side at battery near
end.
[ON], [OFF]
f
Factory setting: [ON]
[BATT END ALARM]
Sets whether to output the warning sound at battery near end.
[ON], [OFF]
f
Factory setting: [ON]
[BATT REMAIN FULL]
Sets the content of the battery remaining charge bar of the status display when a battery with charge level
display function is used.
[70%]:
Displays as full at 70%.
[100%]:
Displays as full at 100%.
f
Factory setting: [70%]