148
Maintenance and Inspections : Warning System
The following error codes are displayed in the display window if an error occurs in the camera:
Confirm the type of warning and refer to the details in the [Warning Description Tables] (page 145) for countermeasures.
Error Codes
Code No.
Description
Type of warnings
E-11
Video initialisation error
E-27
Recording control error
E-30
P2 card removal error
E-34
LCD microcontroller error
E-38
P2 streaming microcontroller error
E-39
Abnormal initialization of the AVC-Intra codec board (optional AJ-YBX200G)
E-3F
Microprocessor error in the camera control circuit.
E-40
Image sequence error (in case of 24P, 30P and 25P)
Image Sequence Error (24P, 30P, 25P)
E-63
Something is wrong with the system control microprocessor.
E-6F
Reference signal error.
00:00:00:11
Recording error on a P2 card
1394 Error Codes
Code No.
Description
Recording
Indication in display
window
1394 E-80
Signals being input to the DVCPRO/DV
connector are not 1
a
speed transfer
signals in DV format.
Stops
The time code section of the
display window indicates the
appropriate error code that
blinks every two seconds.
1394 E-81
Signals being input to the DVCPRO/DV
connector are not 1
a
speed transfer
signals in DVCPRO (25 Mbps) format.
Stops
1394 E-82
Signals being input to the DVCPRO/DV
connector are not 1
a
speed transfer
signals in DVCPRO50 (50 Mbps) format.
Stops
1394 E-83
Incorrect signals are being input to the
DVCPRO/DV connector.
Stops
1394 E-84
Signals being input to the DVCPRO/DV
connector are not in DVCPRO or DV
format.
Stops
1394 E-85
Signals being input to the DVCPRO/DV
connector are not 1x speed transfer signals
in DVCPRO HD format.
Stops
1394 E-87
Incorrect audio signals are being input to
the DVCPRO/DV connector.
Continues with no sound.
1394 E-90
No signal is supplied to the DVCPRO/DV
connector.
While the recording mode continues, no
data is recorded on cards unless the
abnormal condition is corrected. If an
error has occurred before recording, then,
recording does not start.
1394 E-91
With the menu option REC MODE set to
DV, copy guard information signals for
recording prohibited data are being input to
the DVCPRO/DV connector.
Stops
1394 E-92
The DVCPRO/DV connector is not properly
connected. The viewfinder indicates the
message "1394 INITIAL ERROR."
No recording in 1394 input mode can be
performed.
AJ-HPX2000P(VQT1D27-1)E.book 148 ページ 2007年7月30日 月曜日 午後1時31分