4
Chapter 4 Adjustments and settings for recording
29
<Notes>
≥
Check that the lens connector has been connected and
that the lens aperture is set to CLOSE.
≥
While the black balance is being adjusted, the aperture
is automatically set to the light-shielding status.
≥
While the black balance is being adjusted, the gain
selector circuit is switched automatically.
Flicker or noise may appear on the viewfinder screen,
but this is not indicative of malfunctioning.
≥
If the black shading is still unsatisfactory although the
“ABB OK” message is displayed, perform menu
operations to open the <BLACK SHADING> screen
from the MAINTENANCE page, move the arrow mark
(
>
) to the DETECTION item, press the JOG dial
button, and proceed with the black shading adjustment.
If the ABB switch is held down for 5 or more seconds,
the black shading can be automatically adjusted after
the ABB operation. (See the SHD.ABB SW CTL item
under “7-5-5 SW MODE.”)
≥
If the AUTO W/B BAL switch is pushed down to the
ABB position again while the black balance is being
automatically adjusted (ABB ACTIVE), the adjustment
will be aborted.
The adjusted value in this case is the value before
automatic adjustment was performed.
Black balance memory
The values stored in the memory are retained even after the
unit’s power has been turned off.
4-1-2 Adjusting the black balance
The black balance needs to be adjusted in the following
cases:
≥
When the unit is used for the first time
≥
When the unit is used after it has not been used for a
prolonged period of time
≥
When the unit is used in an ambient temperature which has
fluctuated significantly
≥
When the value selected for the gain switch has been
changed
≥
When the super gain setting has been performed using the
USER MAIN, USER1 or USER2 button
≥
When the gamma ON/OFF setting has been changed
1
Set the switches as shown in the figure.
2
Set the AUTO W/B BAL switch to the ABB position, and
then release it.
The switch returns to the center, and the adjustment is
performed.
3
While the adjustment is in progress, the following
message appears on the viewfinder screen.
<Note>
While the adjustment is in progress, the lens aperture is
automatically set to CLOSE.
AUTO W/B BAL switch:
Use this to execute ABB.
OUTPUT:
CAM
ABB ACTIVE
4
Adjustment is completed in several seconds. (A message
similar to the one shown in the figure below now appears.)
The adjustment value is automatically saved in the
memory.
ABB OK