– 130 –
Chapter 7 Menu Operations — Menu list
Item
Description of settings
Remark
ZOOM/FOCUS
Selects the unit of zoom and focus values.
[NUMBER], [mm/m], [mm/feet], [OFF]
f
When [mm/m] or [mm/feet] is selected
Displayed only when an auto-focus compatible lens is attached.
CARD/BATT
Sets the remaining capacity display for P2 card and battery.
[ON], [OFF]
P2CARD REMAIN
Selects the type of P2 card remaining capacity display for recording.
[ONE-CARD]
Displays the remaining capacity of the card currently being
recorded.
[TOTAL]
Displays the total remaining capacity of two cards.
OTHER DISPLAY
Sets other information display items.
[PARTIAL]
Displays partial information.
[ALL]
Displays all information.
[OFF]
Does not display.
MENU BACK
Selects whether to make characters stand out by lowering the background
transmittance while displaying the setting menu.
[ON]
Lowers the background transmittance.
[OFF]
Does not lower the background transmittance.
REC COUNTER
Sets counter operation during recording.
[TOTAL]
Continues counting by integrating until reset with the <RESET>
button.
[CLIP]
Clears the count value when recording starts, and counts time
for each shooting.
indicates factory setting values.
[BATTERY SETUP] screen
Item
Description of settings
Remark
EXT DC IN SEL
Sets the type of external DC power.
[AC ADAPTER]
AC adaptor
[BATTERY]
Battery
BATTERY SELECT
Sets the battery type.
[HYTRON50], [HYTRON140], [DIONIC HC], [DIONIC90], [DIONIC160],
[ENDURA7], [ENDURA10], [PAG L96e], [TYPE A], [TYPE B]
BATTERY MODE
Sets the near end.
[AUTO]
Near end is set automatically with the battery selected with
[BATTERY SELECT].
[MANUAL]
Sets the near end voltage manually.
HYTRON50 NEAR
Sets the near end voltage of [HYTRON50]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
HYTRON140 NEAR
Sets the near end voltage of [HYTRON140]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.1V] ... [15.0V]
DIONIC HC NEAR
Sets the near end voltage of [DIONIC HC]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.1V] ... [15.0V]
DIONIC90 NEAR
Sets the near end voltage of [DIONIC90]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.5V] ... [15.0V]
DIONIC160 NEAR
Sets the near end voltage of [DIONIC160]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
ENDURA7 NEAR
Sets the near end voltage of [ENDURA7]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
ENDURA10 NEAR
Sets the near end voltage of [ENDURA10]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
PAG L96e NEAR
Sets the near end voltage of [PAG L96e]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.1V] ... [15.0V]
TYPE A FULL
Sets the full voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)
[12.0V] ... [15.5V] ... [17.0V]
TYPE A NEAR
Sets the near end voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.0V] ... [15.0V]
TYPE A END
Sets the end voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [12.7V] ... [15.0V]
TYPE B FULL
Sets the full voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)
[12.0V] ... [15.6V] ... [17.0V]
TYPE B NEAR
Sets the near end voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
TYPE B END
Sets the end voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [12.9V] ... [15.0V]
indicates factory setting values.