Specifications
16-48
16.5.13
System Operation Setting Area
●
:
Available, -: Not available
Axis no.
Unit
memory
no. (Hex)
Name
Default Description
R
W
-
UM 0261D
Deceleration
stop
operation
H0
Specify the operation when setting the
deceleration stop request signal to “Active”
(from off to on).
0: Deceleration stop
When performing the repeat operation, stops
after reaching E-point that is targeted for the
repeat operation.
1: Pause
・
Performs the deceleration stop, and restarts
the positioning operation when turning
“Deceleration stop request signal” to off from
on.
・
Also, performs the same operation as the
deceleration stop in all states except during
the positioning operation.
・
When performing the repeat operation, stops
after reaching E-point that is targeted for the
repeat operation, and restarts the positioning
operation when turning “Deceleration stop
request signal” to off from on.
・
If a system stop or emergency stop is
executed while the positioning unit is paused,
the pause state will be canceled and the
operation will not restart with the deceleration
stop request signal is canceled (turned off).
Summary of Contents for AFP7MC16EC
Page 1: ......
Page 19: ...1 Unit Functions and Restrictions ...
Page 28: ...Unit Functions and Restrictions 1 10 ...
Page 29: ...2 Names and Functions of Parts ...
Page 33: ...3 Installation and Wiring ...
Page 47: ...4 Basic Procedure ...
Page 75: ...5 Settings of FP7 MC Unit Using CMI Tool ...
Page 97: ...6 Data Transfer to MC Unit and Test Operation ...
Page 122: ...Data Transfer to MC Unit and Test Operation 6 26 ...
Page 123: ...7 Creation of User Programs ...
Page 131: ...8 Automatic Operation Position Control ...
Page 143: ...8 2 Interpolation Control 8 13 ...
Page 193: ...9 Automatic Operation Synchronous Control ...
Page 251: ...10 Manual Operation JOG Operation ...
Page 257: ...10 2 Changing Speed During JOG Operation 10 7 MEMO ...
Page 263: ...11 Manual Operation Home Return ...
Page 277: ...12 Stop Functions ...
Page 286: ...Stop Functions 12 10 ...
Page 287: ...13 Supplementary Functions ...
Page 336: ...Supplementary Functions 13 50 ...
Page 337: ...14 CMTimeChart Monitor ...
Page 338: ...CMTimeChart Monitor 14 2 14 1 Overview of Function ...
Page 365: ...15 Troubleshooting ...
Page 396: ...Troubleshooting 15 32 ...
Page 397: ...16 Specifications ...
Page 500: ...Specifications 16 104 16 13Dimensions AFP7MC16EC AFP7MC32EC AFP7MC64EC 90 28 80 4 Unit mm ...
Page 502: ......
Page 503: ......
Page 504: ......