Setting Procedure
3-4
3.2 Initial Setting of Ethernet /IP
3.2.1 Ethernet Settings
This is the setting for the communication function via LAN ports including EtherNet/IP. Use
FPWIN GR7 for the setting. The following procedure is explained on the condition that FPWIN
GR7 has already started.
PROCEDURE
1. Select "Option" > "Ethernet settings" from the menu bar.
The "Ethernet settings" dialog box appears.
2. As necessary, change "Home IP address" and "No. of User Connections".
In this example, "IP address = 192.168.1.6", and "No. of User Connections = 5".
3. Change the setting of "EtherNet/IP Function" to "Use".
4. Press the [OK] button.
KEY POINTS
•
The number of connections available for EtherNet/IP is (9-"No. of user
connection"). When the value is "5" which is initial value, the number of
connections available for EtherNet/IP is "4".
•
If the setting of “EtherNet/IP Function” is changed to “Not use”, the
EtherNet/IP setting information will be cleared.