Chapter 2. Error Codes and Screen Messages
20
DigitalFlow™ GM868 Service Manual
2.14 E12: Not Used
This error code message is not currently in use.
2.15 E13: Over Range
Problem:
This error code message indicates that the present measurement exceeds the capacity of the meter.
Cause:
A internal mathematical overflow has occurred in either the volumetric or mass flow calculations.
Action:
Select larger measurement units or a shorter time interval for the current measurement parameter. For
example, choose
KSCF/M
instead of
SCF/M
. See the
Startup Guide for instructions.
2.16 E14: Totals Overflow
Problem:
The totalizers are unable to keep up with the total flow signals.
Cause:
The programmed units/pulse value is too small.
Action:
Select a larger number of units/pulse value.
2.17 E15: Equation Limit
Problem:
The steam measurement may not be within 1% accuracy.
Cause:
The temperature or pressure reading is outside the accuracy specification of the GM868 steam
equations.
Action:
Adjust the pressure reading to within the range of 139.9685 kPa to 2242.9435 kPa, or the temperature
reading to within the range of 373.1500K to 810.9278K.
Summary of Contents for DigitalFlow GM868
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 9: ...DigitalFlow GM868 Service Manual vii Contents...
Page 10: ...Contents viii DigitalFlow GM868 Service Manual...
Page 26: ...Chapter 1 Calibration DigitalFlow GM868 Service Manual 16...
Page 38: ...Chapter 3 Diagnostics 28 DigitalFlow GM868 Service Manual no content intended for this page...
Page 66: ...Warranty 56 DigitalFlow GM868 Service Manual...
Page 70: ...60 DigitalFlow GM868 Service Manual no content intended for this page...
Page 71: ......