![Panametrics C-ET Installation Manual Download Page 13](http://html1.mh-extra.com/html/panametrics/c-et/c-et_installation-manual_3403828013.webp)
Model C-ET Installation Guide
5
1.3.1.1
Application Guide - Wall Thickness (in inches)
Note:
Pipe sizes not suitable for C-ET installations are highlighted in red.
Nomina
l Pipe
Size
Outside
Diamet
er
Schedule
(in)
(in)
10
20
30
STD
40
60
XS
80
100
120
140
160
XXS
Wall Thickness
(in)
3
3.500
0.216
0.216
0.300 0.300
0.438 0.600
3 1/2
4.000
0.226 0.226
0.318
0.318
4
4.500
0.237 0.237
0.337 0.337
0.438
0.531
0.674
5
5.563
0.258 0.258
0.375 0.375
0.500
0.625 0.75
6
6.625
0.280 0.280
0.432 0.432
0.562
0.719
0.864
8
8.625
0.250 0.277 0.322 0.322 0.406 0.500 0.500 0.594 0.719
0.812
0.906 0.875
10
10.750
0.250 0.307 0.365 0.365 0.500 0.500 0.594 0.719
0.844 1.000 1.125
1.000
12
12.750
0.250 0.330 0.375 0.406 0.562 0.500 0.688 0.844 1.000 1.125
1.312
1.000
14
14.000 0.250
0.312 0.375 0.375 0.438 0.594 0.500 0.750 0.938 1.094 1.25
1.406
16
16.000 0.250
0.312 0.375 0.375 0.500 0.656 0.500 0.844 1.031
1.219
1.438
1.594
18
18.000 0.250
0.312 0.438 0.375 0.562 0.750 0.500 0.938 1.156
1.375
1.562
1.781
20
20.00
0
0.250
0.375 0.50
0
0.375 0.594 0.812
0.500 0.938 1.156
1.375
1.562
1.781
22
22.00
0
0.250
0.375 0.50
0
0.375
0.875 0.500 1.125
1.375
1.625
1.875
2.125
24
24.00
0
0.250
0.375 0.562 0.375 0.688 0.989 0.500 1.219
1.531
1.812
2.062 2.344
Summary of Contents for C-ET