Chapter 5. Specifications
42
BWT™ System Installation Guide
5.3 Threaded Buffer Assemblies
Service
Liquids
Mounting
1 in. NPT
Materials
•
Standard: 316L stainless steel
•
Optional: Titanium
Fluid Temperature
•
FSPA Short Buffers: -40°F to 212°F (-40°C to 100°C)
•
FSPA Extended Buffers: -40°F to 600°F (-40°C to 315°C)
5.4 Socket-Weld Buffer Assemblies
Service
Liquids
Mounting
1 in. socket weld
Material
Standard: 316L stainless steel
Fluid Temperature
•
FSPA Short Buffers: -40°F to 212°F (-40°C to 100°C)
5.5 System
Area Classifications
•
Explosion-proof: Class I, Division 1, Groups C&D
•
Flameproof:
BWT:
II 2 G Ex d IIC T6 Gb KEMA 01ATEX2051
Ex d IIC T6 Gb IECEx KEM 09.0010
JB:
II 2 G Ex d IIC T6 Gb DEKRA 13ATEX0120X
Ex d IIC T6 Gb IECEx DEK 13.0034X
European Compliance
Complies with directives 2004/108/EC EMC, 2006/95/EC LVD (Installation Category II, Pollution Degree 2),
94/9/EC ATEX and 97/23/EC PED for DN<25.
Pipe Sizes
2 in. to 30 in. (50 mm to 750 mm), larger sizes upon request
Velocity Ranges
•
Gas service: 0.1 to 150 ft/s (0.03 to 46 m/s)
•
Liquid service: 0.1 to 40 ft/s (0.03 to 12 m/s)
Note:
The maximum flow velocity specification for gases is variable, depending on gas sound speed, ultrasonic
path length and gas density (pressure and molecular weight).
Summary of Contents for BWT System
Page 1: ...panametrics com Flow 916 058 F July 2021 BWT System Installation Guide ...
Page 2: ......
Page 4: ...ii no content intended for this page ...
Page 8: ...Contents BWT System Installation Guide ...
Page 52: ...Chapter 5 Specifications 44 BWT System Installation Guide no content intended for this page ...
Page 54: ...46 BWT System Installation Guide no content intended for this page ...
Page 57: ......