background image

BENTO 32 CONCRETE FIRE PIT

Electronic Ignition

Instal Owner's Manual

WARNING

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this 

or any other appliance.  An LP-cyllinder not connected for use shall not be stored in the 

vicinity of this or any other appliance.

WARNING:

If the information in this manual is not followed exactly, a fire or explosion may result 

causing property damage, personal injury, or loss of life.

CARBON MONOXIDE HAZARD

This appliance can produce carbon monoxide which has no odor. 

Using it in an enclosed space can kill you. 

Never use this appliance in an enclosed space such as a camper, tent, car 

or home.

DANGER

WARNING: FOR OUTDOOR USE ONLY.

Installation and service must be performed by a qualified installer, service 

agency, or gas supplier

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference

Burner conforms to:    ANSI Z21.97/CSA 2.41 - 2017 “Outdoor Decorative Gas Appliances”

 

 

 

CSA-2.17-2017 "Gas-fired Appliances For Use at High Altitudes"

We recommend that our fire pits be 

installed and serviced by professionals 

that are certified in the U.S. by NFI 

(National Fireplace Institute)

DANGER - FIRE OR EXPLOSION HAZARD

If you smell gas:

1. Shut off gas to the appliance. 

2. Extinguish any open flame. 

3. If odor continues, leave the area immediately.

4. After leaving the area, call your gas supplier or fire department.

Failure to follow these instructions could result in fire or explosion, which could 

cause property damage, personal injury, or death.

Summary of Contents for Bento 32 Corten

Page 1: ...ANGER WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain thi...

Page 2: ...l Gas Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn soli...

Page 3: ...UNPACK Account for all parts see p 14 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation holes in base see p 4 5 GAS ELECTRICAL Supply lines are rou...

Page 4: ...000 BTU h 60 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size 18 37 Burner Ports 68 68 Port Size 1 8 1 8 Electrical 120V 15A Outdoor Receptacle Dedicate...

Page 5: ...5 BENTO 32 CONCRETE FIRE PIT Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 72 72 8 13 BENTO 42 BENTO 32 0 CLEARANCE BELOW...

Page 6: ...of operation Maintain safe distance during this time TO ASSEMBLE THE FIRE PIT 1 Connect the Burner Assembly to the gas propane supply using the supplied flex connector and following the instructions o...

Page 7: ...ARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION...

Page 8: ...use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test P...

Page 9: ...a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service...

Page 10: ...the manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Hou...

Page 11: ...urner at regular intervals at least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all time...

Page 12: ...K IGNITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is...

Page 13: ...t is clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace...

Page 14: ...same 1a Pilot Shroud CIR EPC same 2 Pilot Assembly PIL E 410 PIL E 410LP 3 18 Burner Ring CIR 18 BUR same 4 Burner Pan CIR 18 PAN same 5 Venturi CIR VEN 1 same 5a Air Shutter 6 Orifice FIT ORI 18 FIT...

Page 15: ...using CIR E BOX same 2 Dual Solenoid Valve E VAL BASO w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip 8 Igniti...

Page 16: ...l ILLUSTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E...

Page 17: ...at its option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components Any prod...

Reviews: