PA-7000 Series Firewall Module and Interface Card Information
PA-7000 Series Firewall SMC-B Component Descriptions
The following image shows the second-generation SMC (PA-7050 SMC-B and PA-7080 SMC-B),
and the tables describe each SMC component.
Figure 4: PA-7050-SMC-B
Figure 5: PA-7080-SMC-B
Item
Component
Description
1
MGT-A and MGT-B
Two redundant SFP/SFP+ Ethernet ports used to access
the management interface. If both ports are connected,
one port is primary and the other port is secondary. If
a link failure occurs on the primary port, the firewall
automatically fails over to the secondary port.
Configure the ports in
Device
>
Setup
>
Interfaces
.
To manage the firewall during the initial configuration,
change your management computer IP address to
192.168.1.2, connect an RJ-45 cable from your computer
to the MGT port and browse to https:// 192.168.1.1. The
default login name is admin and the default password is
admin.
2
HA1-A and HA1-B
Two enhanced SFP (SFP+) ports for high availability (HA)
control and synchronization. Connect this port directly
from HA1-A port on the first firewall in an HA pair to the
HA1-A port on the second firewall in the pair, or connect
these two ports to each other through a switch or router.
You cannot configure HA1 (control) on NPC data ports or
the MGT port.
PA-7000 Series Firewall Hardware Reference
38
©
2023 Palo Alto Networks, Inc.