PA-7000 Series Firewall Installation
STEP 9 |
are properly inserted and then turn on each of the four AC
power switches located on the back of the chassis. The chassis will power on.
Connect DC Power to a PA-7080 Firewall
The following procedure describes how to connect power to DC power supplies in a PA-7080
firewall. The power supplies require -40VDC to -60VDC power input. For details on power
requirements, see
Determine PA-7000 Series Firewall Power Configuration Requirements
You must connect each of the eight DC power connections (four on each PEM) to separate
60-amp protected circuit breakers, minimum -48VDC, and a double pole on the input to
the DC power.
Due to the various DC cable lengths required in your environment, DC power cables are
not provided with the PA-7080 DC model.
STEP 1 |
.
PA-7000 Series Firewall Hardware Reference
116
©
2023 Palo Alto Networks, Inc.