Connect Power to a PA-5200 Series Firewall
Connect DC Power to a PA-5200 Series Firewall
The following procedure describes how to connect DC power to a PA-5200 Series firewall with
DC power supplies.
To avoid injury to yourself or damage to your Palo Alto Networks
®
hardware or the data
that resides on the hardware, read the
.
STEP 1 |
Remove the two nuts and star washers from the ground studs on the back of the firewall and
then remove the two-hole ground lug.
STEP 2 |
Crimp a 6AWG ground cable (not included) to the two-hole 6AWG ground lug and then
aach the ground lug to the ground studs on the firewall. Replace the star washers and nuts
and torque to 25 in-lbs. Connect the other end of the cable to earth ground.
STEP 3 |
Power off the DC power source that you will connect to the firewall.
STEP 4 |
Aach the DC power cables (not included) from the DC power source to the DC power
supplies on the back of the firewall.
1. Remove the plasc DC power input cover from each of the two DC power supplies and
then remove the posive and negave terminal screws.
2. Crimp ring lugs to the ends of the DC cables. These lugs are used to connect the DC
cables to the DC inputs on the firewall.
3. Use the DC terminal screws to connect a posive (red) DC power cable to the posive
terminal on the first DC power supply and then connect a negave (black) DC power
PA-5200 Series Next-Gen Firewall Hardware Reference
25
©
2021 Palo Alto Networks, Inc.