• Le circuit de protection est conforme aux classifications de test IEC B2, C1, C2, C3, et D1.
• Le courant de décharge normal (cœur vers terre) est de 2kA par paire de signal.
• Le courant de décharge normal (cœur vers cœur) est de 100 A.
• Le courant de décharge total est de 10kA.

• Do not connect a supply voltage that exceeds the input range of the firewall or appliance. For details

on the electrical range, refer to electrical specifications in the hardware reference for your firewall or

appliance.

French Translation:

 Veillez à ce que la tension d’alimentation ne dépasse pas la plage d’entrée du

pare-feu ou du dispositif. Pour plus d’informations sur la mesure électrique, consulter la rubrique des

caractéristiques électriques dans la documentation de votre matériel de pare-feu ou votre dispositif.

• Do not replace a battery with an incorrect battery type; doing so can cause the replacement battery to

explode. Dispose of used batteries according to local regulations.

French Translation:

 Ne remplacez pas la batterie par une batterie de type non adapté, cette dernière

risquerait d’exploser. Mettez au rebut les batteries usagées conformément aux instructions.

• (

All firewalls with two or more power supplies

) Disconnect all power cords (AC or DC) from the power

inputs to fully de-energize the hardware.

French Translation:

 (Tous les pare-feux avec au moins deux sources d’alimentation) Débranchez tous les

cordons d’alimentation (c.a. ou c.c.) des entrées d’alimentation et mettez le matériel hors tension.

• (

PA-7000 Series firewalls only

) When removing a fan tray from a PA-7000 Series firewall, first pull the

fan tray out about 1 inch (2.5cm) and then wait a minimum of 10 seconds before extracting the entire

fan tray. This allows the fans to stop spinning and helps you avoid serious injury when removing the

fan tray. You can replace a fan tray while the firewall is powered on but you must replace it within 45

seconds and you can only replace one fan tray at a time to prevent the thermal protection circuit from

shutting down the firewall.

French Translation:

 (

Pare-feu PA-7000 uniquement

) Lors du retrait d’un tiroir de ventilation d’un pare-

feu PA-7000, retirez tout d’abord le tiroir sur 2,5 cm, puis patientez au moins 10 secondes avant de

retirer complètement le tiroir de ventilation. Cela permet aux ventilateurs d’arrêter de tourner et permet

d’éviter des blessures graves lors du retrait du tiroir. Vous pouvez remplacer un tiroir de ventilation

lors de la mise sous tension du pare-feu. Toutefois, vous devez le faire dans les 45 secondes et vous ne

pouvez remplacer qu’un tiroir à la fois, sinon le circuit de protection thermique arrêtera le pare-feu.

• (

All firewalls with two or more power supplies

) Disconnect all power cords (AC or DC) from the power

inputs to fully de-energize the hardware.

French Translation:

 (

Tous les pare-feux avec au moins deux sources d’alimentation

) Débranchez tous les

cordons d’alimentation (c.a. ou c.c.) des entrées d’alimentation et mettez le matériel hors tension.

The following applies only to Palo Alto Networks firewalls that support a direct current (DC) power source:

French Translation:

 Les instructions suivantes s’appliquent uniquement aux pare-feux de Palo Alto

Networks prenant en charge une source d’alimentation en courant continu (c.c.):
• Do not connect or disconnect energized DC wires to the power supply.

French Translation:

 Ne raccordez ni débranchez de câbles c.c. sous tension à la source d’alimentation.

• The DC system must be earthed at a single (central) location.

French Translation:

 Le système c.c. doit être mis à la terre à un seul emplacement (central).

• The DC supply source must be located within the same premises as the firewall.

French Translation:

 La source d’alimentation c.c. doit se trouver dans les mêmes locaux que ce pare-feu.

• The DC battery return wiring on the firewall must be connected as an isolated DC (DC-I) return.

French Translation:

 Le câblage de retour de batterie c.c. sur le pare-feu doit être raccordé en tant que

retour c.c. isolé (CC-I).

Summary of Contents for PA-220

Page 1: ...PA 220 Next Gen Firewall Hardware Reference paloaltonetworks com documentation...

Page 2: ...for a specific topic go to our search page www paloaltonetworks com documentation document search html Have feedback or questions for us Leave a comment on any page in the portal or write to us at do...

Page 3: ...Wall 22 Install the PA 220 Firewall in a 19 inch Equipment Rack 24 Connect Power to a PA 220 Firewall 29 How to Connect Power to a PA 220 Firewall 31 Service the PA 220 Firewall Hardware 33 Interpret...

Page 4: ...iv TABLE OF CONTENTS...

Page 5: ...u install or service a Palo Alto Networks next generation firewall or appliance The following topics apply to all Palo Alto Networks firewalls and appliances except where noted Tamper Proof Statement...

Page 6: ...6 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Before You Begin 2019 Palo Alto Networks Inc...

Page 7: ...The tracking number provided to you electronically when ordering the product matches the tracking number that is physically labeled on the box or crate The integrity of the tamper proof tape used to s...

Page 8: ...REWALL HARDWARE REFERENCE Before You Begin 2019 Palo Alto Networks Inc Third Party Component Support Before you consider installing third party hardware read the Palo Alto Networks Third Party Compone...

Page 9: ...agency compliance with electromagnetic compliance EMC regulations French Translation D es c bles Ethernet blind s reli s la terre doivent tre utilis s pour garantir la conformit de l organisme aux mis...

Page 10: ...ewall is powered on but you must replace it within 45 seconds and you can only replace one fan tray at a time to prevent the thermal protection circuit from shutting down the firewall French Translati...

Page 11: ...granted only to craft service personnel using a special tool lock and key or other means of security and that is controlled by the authority responsible for the location French Translation Tous les pa...

Page 12: ...12 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Before You Begin...

Page 13: ...and power consumption eight Ethernet ports and dual power adapters for power redundancy The PA 220 firewall enables you to secure your organization through advanced visibility and control of applicat...

Page 14: ...14 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE PA 220 Firewall Overview 2019 Palo Alto Networks Inc...

Page 15: ...agement web interface and perform administrative tasks The firewall also uses this port for management services such as retrieving licenses and updating threat and application signatures 3 CONSOLE por...

Page 16: ...irewall boot messages the Maintenance Recovery Tool MRT and the command line interface CLI Refer to Micro USB Console Port for more information and to download the Windows driver or to learn how to co...

Page 17: ...220 firewall and the table describes each back panel component Item Component Description 1 Power adapter inputs PWR 1 and PWR 2 Use the power inputs to connect power to the firewall Use only the PA 2...

Page 18: ...18 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE PA 220 Firewall Overview...

Page 19: ...ships with the hardware required to install the firewall on a flat surface or on a wall You can also order a rack mount kit to Install the PA 220 Firewall on a Flat Surface Install the PA 220 Firewall...

Page 20: ...20 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Install the PA 220 Firewall 2019 Palo Alto Networks Inc...

Page 21: ...ENCE Install the PA 220 Firewall 21 2019 Palo Alto Networks Inc Install the PA 220 Firewall on a Flat Surface Attach the rubber pads to the recessed circles on the bottom of the firewall and then plac...

Page 22: ...intend to install the firewall STEP 3 Use a 1 Phillips head screwdriver to install the appropriate screws into each of the three marked locations Drywall Press a drywall anchor slightly into the cent...

Page 23: ...e power cord from falling out After you secure the power adapter to the bracket mount the bracket next to the firewall using wood or drywall screws as appropriate You can install an optional second po...

Page 24: ...s and the installation hardware for the right side of the tray are pre installed This enables you to store the right side hardware in the tray for future use if you are installing only one firewall To...

Page 25: ...for use when you install the second firewall 1 Remove one 4 40 x 1 4 screw located on each side of the front cover from each rack tray bracket to detach the rack tray installation hardware from the r...

Page 26: ...x 5 16 screws for each rail and torque to 9 in lbs you will complete the installation after you install the rack tray in the rack as described in the next step STEP 7 With the help of another person...

Page 27: ...rack installation only Slide one back rack mount bracket into each of the two previously installed rack mount rails and secure the brackets to the back rack posts using the appropriate screws for your...

Page 28: ...28 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Install the PA 220 Firewall...

Page 29: ...firewall is powered by an external power adapter that converts an AC power source to DC power The firewall can operate with one power adapter or you can install a second power adapter for power redun...

Page 30: ...30 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Connect Power to a PA 220 Firewall 2019 Palo Alto Networks Inc...

Page 31: ...nd then connect the other end of the cable to earth ground STEP 3 Connect the DC connector from the power adapter into the PWR 1 port on the firewall and tighten the connector nut to secure the cable...

Page 32: ...32 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Connect Power to a PA 220 Firewall...

Page 33: ...pics describe how to interpret the PA 220 status LEDs and how to replace a PA 220 power adapter The power adapter is the only serviceable component on the PA 220 firewall Interpret the LEDs on a PA 22...

Page 34: ...34 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Service the PA 220 Firewall Hardware 2019 Palo Alto Networks Inc...

Page 35: ...er adapter failure a firewall failure that caused an HA failover a drive failure or hardware is overheating and the temperature is above the high temperature threshold Off The firewall is operating no...

Page 36: ...lto Networks Inc LED Description The PWR LED on the front of the firewall shows green if one or both power adapters are connected to the back power inputs If both power adapters are connected and one...

Page 37: ...or damage to your Palo Alto Networks hardware or the data that resides on the hardware read the Product Safety Warnings STEP 1 Unplug the failed power adapter from the AC power source and then turn th...

Page 38: ...38 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE Service the PA 220 Firewall Hardware...

Page 39: ...cs describe the PA 220 firewall hardware specifications For feature capacity and performance information refer to the PA 220 firewall datasheet Physical Specifications Electrical Specifications Enviro...

Page 40: ...40 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE PA 220 Firewall Specifications 2019 Palo Alto Networks Inc...

Page 41: ...H X 6 29 D X 8 07 W 4 1cm X 16cm X 20 5cm The depth measurement includes hardware that protrudes from the back of the firewall If the rubber feet are installed on the bottom of the firewall add 78 2cm...

Page 42: ...rovided by the external power adapter provided The firewall can operate on one power adapter or you can install a second power adapter for power redundancy Input voltage Power adapter AC side 100 240V...

Page 43: ...all environmental specifications Specification Value Operating temperature range 32 F to 104 F 0 to 40 C Non operating temperature 4 F to 158 F 20 to 70 C Humidity tolerance 5 to 90 non condensing Air...

Page 44: ...Firewall Specifications Miscellaneous Specifications The following table describes PA 220 firewall miscellaneous specifications Specification Value Storage capacity One 32GB SSD for system files and...

Page 45: ...ply with the laws and regulations in each country where there are requirements applicable to our products Our products meet standards for product safety and electromagnetic compatibility when used for...

Page 46: ...46 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE PA 220 Firewall Compliance Statements Overview 2019 Palo Alto Networks Inc...

Page 47: ...isk of explosion if battery is replaced by an incorrect type Dispose of used battery according to local regulations Federal Communications Commission FCC statement for a Class B digital device or peri...

Page 48: ...48 PA 220 NEXT GEN FIREWALL HARDWARE REFERENCE PA 220 Firewall Compliance Statements Overview...

Reviews: