background image

PMT

05 

– SPLIT TRANSFORMER 1-3 FOR MICROPHONE LEVELS

MANUFACTURER’S WARRANTY & LIMITATION OF LIABILITY 

The technical data and functional product features may change without notice. We can nevertheless not 
be held responsible or liable for the accuracy and completeness of the information provided.

You can find our current warranty conditions and limitation of liability at: http://www.adamhall.com/media/
shop/downloads/documents/manufacturersdeclarations.pdf

        PROPER DISPOSAL OF THIS PRODUCT 

(WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) 

(Valid in the European Union and other European countries with waste separation) 
This symbol on the product, or the documents accompanying the product, indicates that this appliance 
may not be treated as household waste. This is to avoid environmental damage or personal injury due 
to uncontrolled waste disposal. Please dispose of this product separately from other waste and have it 
recycled to promote sustainable economic activity.

Description

Microphone split transformer with 3 secondary windings. Electrostatic and mu-metal shielding, PCB mount. 
PCB for 4 x PMT-05 available (PCB05). 
 

CAUTION: 

Soldering time on the contact pins should be no more than 5 seconds. No warranty for da-

maged or over-soldered pins!

TECHNICAL SPECIFICATIONS

Ratio:

1:1 + 1:1

Source impedance:

200 Ohm(s) 

Load impedance: 

> 200 Ohm(s) 

Max. level: 

+ 4 dB

Frequency response:  

40 - 20000 Hz 

PCB:  

PCB05

Dimensions: 

EE25 mm 

application: 

mic split

Weight: 

0.07 kg 

© Palmer Audio Tools, Adam Hall GmbH, D-61267 Neu-Anspach, Daimlerstr. 9, Germany TEL: ++49 (0)6081 94190

FAX: ++49 (0)6081 43280 WEB: www.adamhall.com, www.palmer-germany.com EMAIL: [email protected]

SCHEME:

CONNECTIONS: 

(VIEW ON THE PINS)

Footprint 30 x 30 cm, Height 20 mm (excluding pins)

GRID: 

(5 MM)

 

OUT 2

2

1

9

8

7

6

5

4

3

6

9

5

4

1

2

7

8

3

PMT05

IN

OUT 1

OUT 3

GROUND

MICROPHONESPLITBOX

The R* resistors are added for mutual decoupling 

of the individual outputs. The higher the resistance, 

the better the decoupling. At the same time, higher 

resistance values also increase the losses. 100 

ohms is a convenient compromise. A metal film 

resistor with a maximum 1% tolerance should be 

chosen for the highest demands.

GROUNDING:

To prevent ground loops, it makes sense to ground 

the input to only one output socket. However, this 

output socket must always be used first.

PMT05

2

1

3

1

2

3

1

2

3

1

2

3

6

9

5

4

1
2

7
8
3

R*

R*

R*

R*

R*

R*

IN

OUT 

OUT 

OUT 

*

Reviews: