Compliance: OSHA 1926.502, OSHA 1910.66, ANSI Z359.1(07), ANSI Z359.7(11)

EN 795:1996 Class B (CE 0321)

Remo

vable 

Concr

et

e A

nchor

1”

 H

ole

. 10000 LBS

Conf

orms t

o ANSI Z359.1-2007

M

odel: A3410000

Ba

tch# RB10-

XX

X

MFD: MM/Y

YY

Y

Stainless Steel, Aluminium, Zinc Plated Copper, 7x19 Aircraft Cable

Pat # 7,357,363 B2 / 7,011,281 B2 / US 6,729,821 B2

Max

WARNING:

 

ALL PERSONS USING THIS EQUIPMENT MUST 

READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO 

SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD 

BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS 

EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST 

BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE. AVOID 

CONTACT WITH PHYSICAL HAZARDS (THERMAL, CHEMICAL, 

ELECTRICAL, ETC.). MAKE ONLY COMPATIBLE CONNECTIONS.

Phone: 845-548-5655

TAP!!!  

DO NOT REMOVE 

WARNING LABEL!  

CE 0321 / EN 795:1996 Class B  

Compliance: OSHA

 1926.502 & 1910.66 / 

ANSI Z359.1 

 

DO NOT REMOVE 

 

May be used as an anchor point for a leading edge restraint 
system.  See optional anchor points below for example. The 
use of two anchors is not required for leading edge restraint 
systems unless otherwise specified by the manufacturer.  

WORK SURFACE  

Stainless Steel, 

Aluminum, Zinc Plated Copper

, 7x19 

Aircraft Cable 

 

OPTIONAL 

(ANCHOR POINTS)  

WORK SURFACE  

(ANCHOR POINT)  

Concrete must be  3000-

psi or higher and  fully 

cured. Installation  loca-

tion to be approved  by 

a qualified person.  

MINIMUM CLEARANCE 3ft (1m)  

DECK/FLOOR/GROUND LEVEL  

W

ARNING!!! SWING F

ALLS M

AY OC

CUR 

WHEN 

THE 

W

ORKER IS NO

T DIREC

TL

Y UNDER ANCHOR POINT

.  

All products subjected to fall arresting forces should be removed  

from service immediately!  

DRILLING & INSTALLATION INSTRUCTIONS: 

1.

 Drill a 1” (25mm) diameter hole at least 4.5” (114mm) deep. The  

     drilled hole must be straight and perpendicular to the surface.  

     Make sure the hole is of uniform diameter and free of peaks and  

     valleys on the inner wall. 

2.

 Blow hole clean with compressed air. 

3.

 Always inspect the hole carefully when reusing a   

     

     previously drilled hole. 

4.

 When placing anchor, place your thumb inside the anchor loop  

     and your first two fingers around the trigger. Squeeze fingers and  

     thumb together till the trigger and spring fully compress. 

5.

 Insert unit at least 4” (101mm) deep into hole and release the  

     trigger. Do not force. 

6.

 Set the unit with a slight tug on the anchor loop. 

7.

 The stop sleeve must always be partially inserted into the hole.  

REMOVAL INSTRUCTIONS:  

1. 

When removing anchor, place your thumb inside the anchor loop          

     and your first two fingers around the trigger. Squeeze fingers and            

     thumb together till the trigger and spring fully compress. 

2. 

While squeezing the trigger pull the anchor out of the hole. 

3.

 If the anchor becomes stuck, insert a punch, screwdriver or other          

     object into the hole until it touches the top of the cleaning bushing. 

4.

 Lightly tap with a hammer making sure the tool is touching the top         

     of the cleaning bushing while squeezing the trigger (cleaning                   

     bushing should be easily visible at the edge of the hole). 

5.

 If tool was required to remove the anchor, inspect thoroughly for    

     damage after removal. If damage is found remove from service and         

     destroy immediately.  

*The user shall be equipped with 

a means of limiting  the maximum 

dynamic forces exerted on the 

user during the arrest of a fall to a 

maximum of 8 kN (1350-lbf).

PERFORMANCE: 

Static Tensile Strength: 

10,000-lbf  (44kN)  

Maximum Capacity: 

One worker with  

max weight of 310-lbs (140kg) when used 

as a single point anchorage connector for  

personal fall arrest or restraint system

DIMENSIONS: 

Weight:

 1-lbs (453g) 

Length: 

13.75” (349mm) 

Diameter 

1” (25mm)  

REGULATORY COMPLIANCE:

  

ANSI Z359.1-2007, ANSI Z359.7-2011 

OSHA 1926.502, OSHA 1910.66,                  

EN

 

795:1996 Class B CE0321

COMPONENT MATERIALS:  

Aluminum:

 Trigger 

Aircraft Cable: 

Main Cable, Activator Wire 

Polyurethane: 

Loop Cover 

Stainless Steel:

 Cone, Spoons, Stop Sleeve 

Zinc Plated Steel: 

Spring 

Zinc Plated Copper: 

Swage  

min from an

y edge  

10”  

drill

 1”

Ø (25mm) 

  10” 

90º

90º

PROPER LOADING

Good

Best

See Spoon Orientation

Good

See Spoon Orientation

*Best practice for spoon orientation

when loaded 90º to hole.

SPOON ORIENTATION

Best

Ok

Load

Load

=

=

1.5” (38mm)

   

Cleaning Bushing  

Cleaning Ferrule  

7” (178mm)

   

End Termination

   

Stop Sleeve 

   

Spring

 

                   

Swage

   

13.75” (349mm)

   

Heavy Duty Return Wire

   

Trigger  

Anchor Loop

   

3” (76mm)

2” (50.8mm)

   

Spoon   

Main Cable  